Summary
PRRES20173060
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
09/12/2017
09/14/2017
05/08/2019
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/14/2017 09/14/2017
Development Center
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/12/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in the master bedroom and bedroom #2
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
09/12/2017

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
10 Combustion air
Corrective Action Required
09/12/2017

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/12/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 09/14/2017 09/12/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $921.08 $921.08 Paid 09/14/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 09/14/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 09/14/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 09/14/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 09/14/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/14/2017 (3:30) 9/14/2017 09/14/2017
Underslab Plumbing Inspection - Residential Passed 10/17/2017 10/17/2017 at 9:35 AM 10/17/2017
Piers/Caissons Inspection - Residential Passed 11/13/2017 (2:00) 11/13/2017 at 2:05 PM 11/13/2017
Sewer Service Inspection - R Passed 11/28/2017 (1:30) 11/28/2017 at 2:05 PM 11/28/2017
Water Service Inspection - R Passed 12/7/2017 (1:15) 12/7/2017 at 2:55 PM 12/07/2017
Electrical Service Inspection Passed 3/23/2018 3/22/2018 03/22/2018
Gas Service Inspection - Residential Passed 3/23/2018 3/22/2018 03/22/2018
All Rough Inspection - Residential Failed 3/23/2018 3/22/2018 at 2:45 PM 03/22/2018
Miscellaneous Correction
Corrective Action Required
03/22/2018
FRAMING: -Install hangers above front bed -Over cut studs in garage. Nail to sill plate -Block deck door stud -Install joist hanger above gfci box near ac -Fb rear basement bed closet wall from joist space -Over cut stud at rear basement bed; tighten all anchor nut ELECTRICAL: -Install a receptacle at foyer(with area >5.6 sq meters) wall > 3 ft -Protect wiring at bottom plate near range -Bond hydrotub motor -Secure wiring within 12” of panel -Secure and support wiring at interval no more than 4.5 ft in unfinished basement ceiling MECHANICAL: -Upper combustion air opening -Pan off return air from soffit space at rear basement bed; seal penetrations ***OK TO INSULATE
All Rough Inspection - Residential Passed 4/4/2018 4/4/2018 at 8:35 AM 04/04/2018
Miscellaneous Correction
Resolved
04/04/2018
FRAMING: -Install hangers above front bed -Over cut studs in garage. Nail to sill plate -Block deck door stud -Install joist hanger above gfci box near ac -Fb rear basement bed closet wall from joist space -Over cut stud at rear basement bed; tighten all anchor nut ELECTRICAL: -Install a receptacle at foyer(with area >5.6 sq meters) wall > 3 ft -Protect wiring at bottom plate near range -Bond hydrotub motor -Secure wiring within 12” of panel -Secure and support wiring at interval no more than 4.5 ft in unfinished basement ceiling MECHANICAL: -Upper combustion air opening -Pan off return air from soffit space at rear basement bed; seal penetrations ***OK TO INSULATE
Sidewalk Inspection Partial 4/30/2018 4/30/2018 at 7:00 AM 04/30/2018
PW-Misc
Informational
04/30/2018
Jeremy Young 04/30/2018 7:08 AM Contractor has at least 4" of compacted aggregate base. They have under 1.5% cross slope which meets ADA standards. They will add expansion joints.
Driveway Inspection Partial 4/30/2018 4/30/2018 at 7:05 AM 04/30/2018
Informational
04/30/2018
Jeremy Young 04/30/2018 7:11 AM Contractor has at least 4" of compacted aggregate base. I have advised them to stay under 2.0% cross slope where the sidewalk will pass through the driveway. They will add expansion joints.
Sidewalk Inspection Passed 5/3/2018 at 1:00 PM 05/03/2018
PW-Misc
Informational
04/30/2018
Jeremy Young 04/30/2018 7:08 AM Contractor has at least 4" of compacted aggregate base. They have under 1.5% cross slope which meets ADA standards. They will add expansion joints.
PW-Misc
Informational
05/03/2018
Jeremy Young 05/03/2018 1:07 PM Contractor has poured the sidewalk. They have sufficient compacted rock base. The sidewalk has between .02-1.8% cross slope which meets ADA standards.
Driveway Inspection Passed 5/3/2018 at 1:05 PM 05/03/2018
Informational
05/03/2018
Jeremy Young 05/03/2018 1:09 PM Contractor has poured the driveway approach. They have added the expansion joints and the approach is at least 6" thick. They have between 1.0-1.6% cross slope which meets ADA standards.
Occupancy Inspection - Codes Residential Failed 5/7/2019 5/7/2019 at 9:05 AM 05/07/2019
Misc
Corrective Action Required
05/07/2019
-Seal exterior wall penetrations -Secure AC whip -Install flat 2x4 at top of garage stair handrail for graspable requirement; since this is a required handrail now, because of the 4 risers. -Install sprak rings for all countertop receptacle boxes recessed more than 1/4” behind backsplash -Deck light&fan not powered -Install breaker lock for out-of-sight water heater -Securely fasten gfci receptacle box below outdoor cam video recorder
Occupancy Inspection - Codes Residential Full C of O 5/8/2019 5/8/2019 at 8:50 AM 05/08/2019
Misc
Resolved
05/08/2019
-Seal exterior wall penetrations -Secure AC whip -Install flat 2x4 at top of garage stair handrail for graspable requirement; since this is a required handrail now, because of the 4 risers. -Install sprak rings for all countertop receptacle boxes recessed more than 1/4” behind backsplash -Deck light&fan not powered -Install breaker lock for out-of-sight water heater -Securely fasten gfci receptacle box below outdoor cam video recorder
Documents & Images
Date Uploaded File Type Document Name
09/12/2017 Letter Codes Residential Plan Review
09/14/2017 Receipt Receipt for transaction: 2017-006362
09/14/2017 Letter Codes Building Permit
09/14/2017 Plot Plan DOC091417
09/14/2017 Letter Inspection Summary
10/17/2017 Letter Inspection Summary
11/13/2017 Letter Inspection Summary
11/28/2017 Letter Inspection Summary
12/07/2017 Letter Inspection Summary
03/22/2018 Letter Inspection Summary
04/04/2018 Letter Inspection Summary
04/30/2018 Letter DE-Daily Inspection Summary
05/03/2018 Letter DE-Daily Inspection Summary
05/07/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter Codes Final Certificate of Occupancy
05/08/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home