Summary
PRRES20170715
Building Permit - Residential
Certificate of Occupancy
JOHNSTON RE HOLDINGS LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK
03/16/2017
03/22/2017
08/02/2018
Locations
Contacts
JOHNSTON RE HOLDINGS LLC, Address:801 NE DEL LAGO CT  
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/20/2017 03/21/2017
Kim Brennan
Plot Plan Review Approved 03/20/2017 03/21/2017
Nick Lightner
PW-Misc
Corrective Action Required
03/16/2017

Needs to call out top of the curb on the corners and at the driveway.
Plot Plan Review Rejected 03/20/2017 03/16/2017
Nick Lightner
PW-Misc
Corrective Action Required
03/16/2017

Needs to call out top of the curb on the corners and at the driveway.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $743.19 $743.19 Paid 03/21/2017
Right of Way Permit Fee $75.00 $75.00 Paid 03/21/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/21/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 03/21/2017
Water Meter Fee $405.36 $405.36 Paid 03/21/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/23/2017 03/23/2017
Erosion Control Inspection Residential Failed 05/10/2017
Misc
Corrective Action Required
05/10/2017
-INSTALL EROSION CONTROL
Underslab Plumbing Inspection - Residential Not Ready 5/10/2017 5/10/2017 05/10/2017
Misc
Corrective Action Required
05/10/2017
REQUESTED INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
Underslab Plumbing Inspection - Residential Passed 5/15/2017 5/15/2017 05/15/2017
Misc
Resolved
05/15/2017
REQUESTED INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
Erosion Control Inspection Residential Partial 05/15/2017
Misc
Partial Correction
05/15/2017
All Rough Inspection - Residential Not Ready 8/1/2017 8/1/2017 at 10:15 AM 08/01/2017
All Rough Inspection - Residential Partial 8/8/2017 8/8/2017 08/08/2017
Misc
Partial Correction
08/08/2017
FOUNDATION STRAPS INSTALLED, NOT A COMPLETE INSPECTION
All Rough Inspection - Residential Not Ready 9/25/2017 9/25/2017 at 9:20 AM 09/25/2017
Misc
Corrective Action Required
09/25/2017
PLEASE HAVE APPROVED PLANS ON SITE FOR INSPECTION
Erosion Control Inspection Residential Failed 9/27/2017 at 1:40 AM 09/27/2017
Misc
Corrective Action Required
09/27/2017
Repair erosion control before further inspection.
Gas Service Inspection - Residential Not Ready 9/27/2017 9/27/2017 at 1:50 AM 09/27/2017
Misc
Corrective Action Required
09/27/2017
No pressure
Electrical Service Inspection Not Ready 9/27/2017 9/27/2017 at 1:55 AM 09/27/2017
Misc
Corrective Action Required
09/27/2017
Service conductors not connected in main panel.
All Rough Inspection - Residential Not Ready 9/27/2017 9/27/2017 at 2:00 AM 09/27/2017
Misc
Corrective Action Required
09/25/2017
-PLEASE HAVE APPROVED PLANS ON SITE FOR INSPECTION -GAS: NO PRESSURE -ELECTRIC: SERVICE CONDUCTORS NOT CONNECTED REPAIR EROSION CONTROL BEFORE FURTHER INSPECTION
Erosion Control Inspection Residential Partial 10/2/2017 at 10:05 AM 10/02/2017
Misc
Partial Correction
10/02/2017
Compliant. Maintain.
Gas Service Inspection - Residential Not Ready 10/2/2017 10/2/2017 at 10:10 AM 10/02/2017
Misc
Corrective Action Required
09/27/2017
No pressure
Electrical Service Inspection Not Ready 10/2/2017 10/2/2017 at 12:30 PM 10/02/2017
Misc
Corrective Action Required
09/27/2017
Service conductors not connected in main panel.
Gas Service Inspection - Residential Passed 10/2/2017 at 12:35 PM 10/02/2017
Misc
Resolved
10/02/2017
No pressure
Gas Piping Inspection - Residential Passed 10/2/2017 at 12:45 PM 10/02/2017
All Rough Inspection - Residential Failed 10/2/2017 10/2/2017 at 12:50 PM 10/02/2017
Misc
Corrective Action Required
09/27/2017
1. BSMT: Anchor sill plates within 12" of ends of plates - multiple locations. 2. BSMT: Secure SEC above panel. 3. BSMT: Electric service not ready - conductors not connected in panel. 4. BSMT: Security blocking at rear door - 3 stud bays. 5. BSMT: Stub vent for future bath. 6. 1st FLR: LVL over breakfast nook should be tripled (not doubled). 7. 1st FLR: Firestop tops of walls around living room, at change of ceiling height. 8. ATTIC: Slope DWV.
Electrical Service Inspection Failed 10/16/2017 10/16/2017 at 12:25 PM 10/16/2017
Misc
Corrective Action Required
10/02/2017
UFA ground not adequately connected (loose).
All Rough Inspection - Residential Failed 10/16/2017 10/16/2017 at 12:15 PM 10/16/2017
Misc
Corrective Action Required
10/02/2017
2. BSMT: Secure SEC above panel. 3. BSMT: UFA ground not adequately connected (loose). 5. BSMT: Stub vent for future bath. 8. ATTIC: Slope DWV.
Electrical Service Inspection Passed 10/19/2017 10/19/2017 at 9:15 AM 10/19/2017
Misc
Resolved
10/19/2017
UFA ground not adequately connected (loose).
All Rough Inspection - Residential Failed 10/19/2017 10/19/2017 at 9:20 AM 10/19/2017
Misc
Corrective Action Required
10/16/2017
REMOVE OVERGROWN WEEDS BEFORE FURTHER INSPECTION. 8. ATTIC: Slope DWV. *Sloped; now needs support. (Over laundry.) OK to insulate.
Piers/Caissons Inspection - Residential Passed 10/27/2017 (9:45) 10/27/2017 at 12:05 PM 10/27/2017
All Rough Inspection - Residential Passed 10/30/2017 10/30/2017 at 9:20 AM 10/30/2017
Misc
Resolved
10/30/2017
REMOVE OVERGROWN WEEDS BEFORE FURTHER INSPECTION. 8. ATTIC: Slope DWV. *Sloped; now needs support. (Over laundry.) OK to insulate.
Water Service Inspection - R Partial 12/5/2017 (1:00) 12/5/2017 at 1:10 PM 12/05/2017
Water Service Inspection - R Passed 12/6/2017 (1:30) 12/6/2017 at 1:35 AM 12/06/2017
Sewer Service Inspection - R Passed 12/8/2017 (1:00) 12/8/2017 at 12:45 PM 12/08/2017
Driveway Inspection Partial 3/5/2018 at 11:20 AM 03/05/2018
Informational
03/05/2018
Brice Lawson 03/05/2018 11:36 AM The driveway approach forms are set. It appears that the rock has been compacted. It appears that a max. cross slope of 2% can be achieved where the sidewalk will run through the driveway approach.
Driveway Inspection Partial 3/12/2018 at 1:35 PM 03/09/2018
Informational
03/09/2018
Brice Lawson 03/09/2018 1:56 PM The driveway is being poured and they used 4K KCMMB concrete mix for the driveway approach. The contractor had questions about the proposed ADA and sidewalk tie-in that I will look into.
Driveway Inspection Passed 3/19/2018 at 8:20 AM 03/14/2018
Informational
03/14/2018
Brice Lawson 03/14/2018 8:24 AM The driveway approach has been installed. The cross slope of the sidewalk through the driveway is less than 2.0%. 4K KCMMB concrete mix was used.
Miscellaneous Inspection Partial 3/14/2018 at 8:31 AM 03/14/2018
Corrective Action Required
03/14/2018
Brice Lawson 03/14/2018 8:27 AM There is a part of the curb that is broken in front of the driveway approach. It appears that the curb has been broken for some time. I asked the contractor to patch this area when the driveway approach was being poured. He said he would take care of it. The sidewalk still needs to be installed, so I will remind him to patch the curb at the sidewalk inspection.
Sidewalk Inspection Partial 5/18/2018 5/24/2018 at 2:20 PM 05/24/2018
PW-Misc
Informational
05/24/2018
John DiMauro 05/24/2018 2:25 PM The froms are up and the rock is compacted. I asked Bill not to tie the new sidewalk into the existing due to the existing sidewalk being out of compliance.
Sidewalk Inspection Failed 5/30/2018 at 2:30 PM 05/30/2018
PW-Misc
Informational
05/24/2018
John DiMauro 05/24/2018 2:25 PM The froms are up and the rock is compacted. I asked Bill not to tie the new sidewalk into the existing due to the existing sidewalk being out of compliance.
PW-Misc
Informational
05/30/2018
John DiMauro 05/30/2018 1:49 PM The entire sidewalk on the south side of the driveway appears to have been damaged from rain shortly after is was poured. The sidewalk is not acceptable by the city standards.
Sidewalk Inspection Partial 6/8/2018 at 9:35 AM 06/08/2018
PW-Misc
Informational
05/30/2018
John DiMauro 05/24/2018 2:25 PM The froms are up and the rock is compacted. I asked Bill not to tie the new sidewalk into the existing due to the existing sidewalk being out of compliance.
PW-Misc
Informational
05/30/2018
John DiMauro 05/30/2018 1:49 PM The entire sidewalk on the south side of the driveway appears to have been damaged from rain shortly after is was poured. The sidewalk is not acceptable by the city standards.
PW-Misc
Informational
06/08/2018
John DiMauro 06/08/2018 9:57 AM The crew tore out the damaged sidewalk and are going to pour the new sidewalk today. The forms are up and the rock is compacted.
Sidewalk Inspection Passed 6/12/2018 at 11:15 AM 06/12/2018
PW-Misc
Informational
06/08/2018
John DiMauro 05/24/2018 2:25 PM The froms are up and the rock is compacted. I asked Bill not to tie the new sidewalk into the existing due to the existing sidewalk being out of compliance.
PW-Misc
Informational
06/08/2018
John DiMauro 05/30/2018 1:49 PM The entire sidewalk on the south side of the driveway appears to have been damaged from rain shortly after is was poured. The sidewalk is not acceptable by the city standards.
PW-Misc
Informational
06/08/2018
John DiMauro 06/08/2018 9:57 AM The crew tore out the damaged sidewalk and are going to pour the new sidewalk today. The forms are up and the rock is compacted.
PW-Misc
Informational
06/12/2018
John DiMauro 06/12/2018 11:17 AM The sidewalk cross slope is less than 2.0 percent.
Occupancy Inspection - Codes Residential Failed 7/20/2018 at 10:20 AM 07/20/2018
Misc
Corrective Action Required
07/20/2018
-- LOOSE OUTLET AT REFRIGERATOR - LOOSE OUTLET AT MASTER LEFT OF DOOR - WINDOW SCREENS THROUGHOUT - JOIST HANGERS AT UNDER DECK SMOKE ALARM IN GUEST BED HALL IS SMOKE ONLY NEEDS TO BE COMBO SMOKE/CM
Plot Plan Inspection Passed 08/02/2018
Occupancy Inspection - Codes Residential Full C of O 8/2/2018 at 11:00 AM 08/02/2018
Misc
Corrective Action Required
07/20/2018
-- LOOSE OUTLET AT REFRIGERATOR - LOOSE OUTLET AT MASTER LEFT OF DOOR - WINDOW SCREENS THROUGHOUT - JOIST HANGERS AT UNDER DECK SMOKE ALARM IN GUEST BED HALL IS SMOKE ONLY NEEDS TO BE COMBO SMOKE/CM
Documents & Images
Date Uploaded File Type Document Name
03/21/2017 Receipt Receipt for transaction: 2017-001019
03/21/2017 Letter Codes Building Permit
03/22/2017 Plot Plan DOC032217-001
03/23/2017 Letter Inspection Summary
05/10/2017 Letter Inspection Summary
05/15/2017 Letter Inspection Summary
08/01/2017 Letter Inspection Summary
08/08/2017 Letter Inspection Summary
09/25/2017 Letter Inspection Summary
09/27/2017 Letter Inspection Summary
10/02/2017 Letter Inspection Summary
10/02/2017 Letter Inspection Summary
10/16/2017 Letter Inspection Summary
10/19/2017 Letter Inspection Summary
10/27/2017 Letter Inspection Summary
10/30/2017 Letter Inspection Summary
12/05/2017 Letter Inspection Summary
12/06/2017 Letter Inspection Summary
12/08/2017 Letter Inspection Summary
03/05/2018 Letter DE-Daily Inspection Summary
03/14/2018 Letter DE-Daily Inspection Summary
05/24/2018 Letter DE-Daily Inspection Summary
05/30/2018 Letter DE-Daily Inspection Summary
06/08/2018 Letter DE-Daily Inspection Summary
06/12/2018 Letter DE-Daily Inspection Summary
07/20/2018 Letter Inspection Summary
08/02/2018 Letter Codes Final Certificate of Occupancy
08/03/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home