Summary
PRRES20170306
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST REAL EST DEV INC
NEW 3 OR 4 FAMILY
NEW 4 PLEX WITH FINISHED BASEMENT AND WALKOUT
02/08/2017
03/16/2017
10/05/2017
Locations
Contacts
HUNT MIDWEST REAL EST DEV INC, Address:8300 NE UNDERGROUND DR  
STUCKER CONSTRUCTION INC, Address:1120 NW EAGLE RIDGE BLVD, Phone:(816) 795-1317  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
STAR ELECTRICAL, Address:P O BOX 1755, Phone:(816) 694-0982  
EAGLE CREEK RENTALS LLC, Address:301 SW MARKET ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/10/2017 02/23/2017
Nick Lightner
Plot Plan Review (P&D) Approved 02/10/2017 02/22/2017
Shannon McGuire
Residential Plan Review Approved 02/10/2017 02/09/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $2,320.15 $2,320.15 Paid 03/15/2017
8331507-Sewer Connection Fee $1,500.00 $1,500.00 Paid 03/15/2017
8331401-Water Tap Fee $13,240.00 $13,240.00 Paid 03/15/2017
8350015-Water Meter Fee $1,621.44 $1,621.44 Paid 03/15/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 03/15/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/21/2017 (10:00) 3/21/2017 03/21/2017
Erosion Control Inspection Residential Partial 03/21/2017
Underslab Plumbing Inspection - Residential Passed 4/26/2017 04/26/2017
Underslab Electrical Inspection - Residential Passed 4/26/2017 04/26/2017
Erosion Control Inspection Residential Partial 04/26/2017
Sewer Service Inspection - R Partial 5/11/2017 (1:00) 5/11/2017 05/11/2017
Misc
Partial Correction
05/11/2017
PARTIAL: 2230 & 2232 DONE. 2234 & 2236 NOT DONE.
Sewer Service Inspection - R Passed 5/12/2017 (2:00) 5/12/2017 05/12/2017
Misc
Resolved
05/12/2017
PARTIAL: 2230 & 2232 DONE. 2234 & 2236 NOT DONE.
Water Service Inspection - R Passed 5/23/2017 (10:45) 5/23/2017 05/23/2017
Electrical Service Inspection Failed 7/31/2017 7/31/2017 07/31/2017
Misc
Corrective Action Required
07/31/2017
Grounding conductor from UFA enters meter bank, but is not connected to anything.
Rated Assembly Inspection Failed 7/31/2017 7/31/2017 07/31/2017
Misc
Corrective Action Required
07/31/2017
see all rough list.
All Rough Inspection - Residential Failed 7/31/2017 7/31/2017 07/31/2017
Misc
Corrective Action Required
07/31/2017
1. Grounding conductor from UFA enters meter bank, but is not connected to anything. 2. Firestopping is incomplete. For example: every 10' along common walls; at ceiling level over each side of laundry rooms; sole- and top-plate penetrations; at either side of the short stair leading to the upper/rear bedrooms; etc. 3. Corner nailing. 4. Fully nail joist hangers. 5. Support DWV every 4'. 6. DWV piping run across attic access opening. UNIT 2230: Nail-guard plates for elec. wire at a few locations throughout unit. UNIT 2232: Missing ridge support. UNIT 2236: Hole in common-wall fire-rock at top of stairs to upper floor.
All Rough Inspection - Residential Failed 8/1/2017 08/01/2017
Misc
Corrective Action Required
07/31/2017
Do not cover Common items comply to all units, fire stopping of walls, dbl walls, heat chase from floor to floor and joist space, plumbing support, notching of joist, over drilled joist, nailing of 2x10 rafters to blocking for bearing. Fire wall clips, shaft wall needs to run to roof deck and 48" out each side. .2236 -Blocking of rafters front bedroom. Nail rafters to 2x10 blocks or support rafters per code. -Firstop flue chase 1st floor -Bath vent hanging out of garage ceiling .need fire stopped and furred around. -Heat chase 2nd floor bath or linen closet? Fur out. And firestopped. -Security blocking Bsmt doors. 3 stud bays each side of sliding door. -Support rear I beam full width , edge supporting I beam. -plumbing support 2234 -Bsmt cut joist north of slider notched for plumbing. -Wall bracing 2nd floor, install per code. -2nd floor bath vent hanging in bath room not connected in attic. -X bracing 2nd floor loose, over 45 -Missing joist hanger nails lvl front bedroom 2nd floor. -Rock on roof doesn't extend 4 ft front deb closet. -Fire wall north side over stairs incomplete to roof. -No shaft wall supports this unit. 2230 joist over kitchen over drilled, and within 2 "'of bottom of the joist . -Kitchen** Wall joist need supported topmplates cut for hvac install studs under joist . -Plumbing support. -Security blocking 3 stud bays both side of door Firstop 1st floor heat chase vert hor joist space . -Bath vent needs furred out in garage ceiling. - Missing joist hanger nails lvl in garage . 2232 -Missing joist hanger nails garage., joist hanger nails I beam over kitchen. -Firstop heat chase 1st floor. -Toilet flange incomplete mstr bath. -Fire wall above mstr closet doesn't connect to roof deck. -2nd floor bath vent hanging in shower. -X bracing over 45 front bedroom -Seal firewall at ridge north end .
Erosion Control Inspection Residential Failed 08/01/2017
All Rough Inspection - Residential Failed 8/2/2017 08/02/2017
Misc
Corrective Action Required
08/01/2017
ok to insulate 2236 support i beam bsmt full width 2234 connect 2nd floor shower all units firestop vertical to horizontal heat chase 1st floor left to right in josit space.
Electrical Service Inspection Passed 8/2/2017 08/02/2017
Misc
Corrective Action Required
07/31/2017
Grounding conductor from UFA enters meter bank, but is not connected to anything.
Rated Assembly Inspection Passed 8/2/2017 08/02/2017
Misc
Resolved
08/02/2017
-Hole in common-wall fire-rock at top of stairs to upper floor in Unit 2236. -Firestop every 10'.
All Rough Inspection - Residential Passed 8/7/2017 08/07/2017
Misc
Resolved
08/02/2017
ok to insulate 2236 support i beam bsmt full width 2234 connect 2nd floor shower all units firestop vertical to horizontal heat chase 1st floor left to right in josit space.
Piers/Caissons Inspection - Residential Passed 8/9/2017 (1:00) 8/9/2017 08/09/2017
Driveway Inspection Partial 8/25/2017 8/25/2017 at 9:40 AM 08/25/2017
Informational
08/25/2017
Tom Chandler 08/25/2017 9:50 AM Inspected forms and compacted aggregate only.
Sidewalk Inspection Partial 8/25/2017 8/25/2017 at 9:40 AM 08/25/2017
Informational
08/25/2017
Tom Chandler 08/25/2017 9:53 AM Inspected forms and compacted aggregate only.
Occupancy Inspection - Codes Residential Failed 8/29/2017 8/29/2017 at 2:30 AM 08/29/2017
Misc
Corrective Action Required
08/29/2017
32-34 needs guard rail at bsmt stairs per code. ok to move items in 2234, scott will be there after 8:30 for re-inspect exterior items sod, erosion control, water meter.
Occupancy Inspection - Codes Residential Temporary C of O 8/30/2017 at 8:00 AM 08/30/2017
Misc
Corrective Action Required
08/29/2017
street and curb, driveway, sidewalk. exterior items sod, erosion control, water meter.
Sidewalk Inspection Passed 9/8/2017 at 8:15 AM 09/08/2017
Informational
09/08/2017
Tom Chandler 09/08/2017 10:41 AM Sidewalk has been completed and passed final inspection.
Driveway Inspection Passed 9/8/2017 at 8:15 AM 09/08/2017
Informational
09/01/2017
Tom Chandler 09/01/2017 10:06 AM Driveway has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Full C of O 9/19/2017 10/5/2017 at 11:00 AM 10/05/2017
Misc
Resolved
09/29/2017
PORCH RAIL
Documents & Images
Date Uploaded File Type Document Name
03/15/2017 Receipt Receipt for transaction: 2017-000917
03/15/2017 Letter Codes Building Permit
03/21/2017 Letter Inspection Summary
04/26/2017 Letter Inspection Summary
05/11/2017 Letter Inspection Summary
05/12/2017 Letter Inspection Summary
05/23/2017 Letter Inspection Summary
07/31/2017 Letter Inspection Summary
08/01/2017 Letter Inspection Summary
08/02/2017 Letter Inspection Summary
08/07/2017 Letter Inspection Summary
08/09/2017 Letter Inspection Summary
08/25/2017 Letter PW-Daily Inspection Summary
08/29/2017 Letter Inspection Summary
08/30/2017 Letter Codes Temporary Certificate of Occupancy
09/08/2017 Letter DE-Daily Inspection Summary
10/05/2017 Letter Codes Final Certificate of Occupancy
10/06/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home