Summary
PRRES20170094
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT STOP WORK ORDER generated on 02/07/2017 12:00 AM by username 'Mike Copeland'. STOP WORK ORDER removed on 02/09/2017 12:00 AM by username 'Mike Copeland'.
01/13/2017
01/17/2017
08/29/2017
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 01/18/2017 01/17/2017
Jonathon Hilton
Plot Plan Review Approved 01/18/2017 01/17/2017
Jonathon Smith
Residential Plan Review Approved 01/18/2017 01/13/2017
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $859.19 $859.19 Paid 01/17/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/17/2017
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/17/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 01/17/2017
Water Meter Fee $405.36 $405.36 Paid 01/17/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 2/3/2017 (10:45) 2/3/2017 02/03/2017
Misc
Corrective Action Required
02/03/2017
Footings shall be a minimum of 8" thick per the engineer report. Do not pour
Footing Inspection - Residential Passed 2/3/2017 (11:30) 2/3/2017 02/03/2017
Misc
Resolved
02/03/2017
Footings shall be a minimum of 8" thick per the engineer report. Do not pour
Foundation Inspection - Residential Failed 2/7/2017 02/07/2017
Misc
Corrective Action Required
02/07/2017
SPOT CHECKED STEEL IN FOUNDATION WALL, NONE OF THE STEEL HAS BEEN TIED OFF. DO NOT POUR UNTIL INSPECTED AND APPROVED. STOP WORK ISSUED OTHER THAN CORRECTING THE VIOLATION.
Foundation Inspection - Residential Failed 02/08/2017
Misc
Corrective Action Required
02/07/2017
Second Inspection, multiple areas with no steel overlap, several corners still not tied and no overlap. Do not pour. STOP WORK ISSUED OTHER THAN CORRECTING THE VIOLATION.
Foundation Inspection - Residential Passed 2/9/2017 02/09/2017
Misc
Resolved
02/09/2017
Second Inspection, multiple areas with no steel overlap, several corners still not tied and no overlap. Do not pour. STOP WORK ISSUED OTHER THAN CORRECTING THE VIOLATION.
Sewer Service Inspection - R Passed 2/15/2017 (1:00) 2/15/2017 02/15/2017
Water Service Inspection - R Passed 2/16/2017 (9:00) 2/16/2017 02/16/2017
Underslab Plumbing Inspection - Residential Passed 2/28/2017 2/28/2017 02/28/2017
All Rough Inspection - Residential Not Ready 5/24/2017 5/24/2017 05/24/2017
Misc
Corrective Action Required
05/24/2017
-PLEASE HAVE PLANS ON SITE FOR INSPECTION
All Rough Inspection - Residential Not Ready 5/26/2017 5/26/2017 05/26/2017
Misc
Corrective Action Required
05/24/2017
-REAR WALL CS-PF DETAIL, BRACED WALLS, CORNER STUD NAILING........NOT READY FOR INSPECTION
All Rough Inspection - Residential Failed 6/2/2017 6/2/2017 06/02/2017
Misc
Corrective Action Required
05/26/2017
1. Corner stud in NECorner bsmt not framed per code. 2. Stairway headroom clearance. 3. Install straps at bored top-plates per *NOTE, below. 4. Firestop the ends of the steel beam furr-outs in the basement (3 locations where intersect with perimeter walls). 5. Firestop around the sanitary pipe where it passes through the existing firestop-assembly at the West wall of the basement. *NOTE: WOOD WALL FRAMING. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie of not less than 0.054 inch thick (1.37 mm) (16 ga) and 1½ inches (38 mm) wide shall be fastened across and to the plate at each side of the opening with not less than eight 16d nails at each side or equivalent. See Figure R602.6.1. Exception: When the entire side of the wall with the notch or cut is covered by wood structural panel sheathing.
Gas Service Inspection - Residential Passed 5/26/2017 6/2/2017 06/02/2017
Electrical Service Inspection Passed 5/26/2017 6/2/2017 06/02/2017
All Rough Inspection - Residential Failed 6/13/2017 6/13/2017 06/13/2017
Misc
Corrective Action Required
06/02/2017
1. Corner stud in NECorner bsmt not framed per code. 2. Firestop the ends of the steel beam furr-outs in the basement (3 locations where intersect with perimeter walls). 3. Firestop around the sanitary pipe where it passes through the existing firestop-assembly at the West wall of the basement.
All Rough Inspection - Residential Passed 6/16/2017 6/16/2017 06/16/2017
Misc
Resolved
06/16/2017
1. Corner stud in NECorner bsmt not framed per code. 2. Firestop the ends of the steel beam furr-outs in the basement (3 locations where intersect with perimeter walls). 3. Firestop around the sanitary pipe where it passes through the existing firestop-assembly at the West wall of the basement.
Driveway Inspection Partial 6/27/2017 6/27/2017 06/27/2017
Informational
06/27/2017
John DiMauro 06/27/2017 10:13 AM forms are up and rock is compacted.
Driveway Inspection Passed 6/29/2017 06/29/2017
Informational
06/29/2017
John DiMauro 06/29/2017 1:53 PM
Occupancy Inspection - Codes Residential Failed 8/21/2017 8/21/2017 at 10:00 AM 08/21/2017
Misc
Corrective Action Required
08/21/2017
**INSTALL EROSION CONTROL AT THE REAR OF PROPERTY. DISCHARGING INTO THE CREEK. PROTECT THE STREET FRONT.*** -LOWER WATER METER TO FINISH GRADE. MAKE SURE METER IS 14"-18" FROM THE LID. -INSTALL FINAL GRADE, SOD, DOWNSPOUTS, SPLASHBLOCKS. -PROTECT I JOISTS IN UNFINISHED BASEMENT.
Occupancy Inspection - Codes Residential Temporary C of O 8/23/2017 8/23/2017 at 2:15 AM 08/23/2017
Misc
Corrective Action Required
08/21/2017
-LOWER WATER METER TO FINISH GRADE. MAKE SURE METER IS 14"-18" FROM THE LID. -INSTALL FINAL GRADE, SOD, DOWNSPOUTS, SPLASHBLOCKS.
Occupancy Inspection - Codes Residential Full C of O 8/29/2017 8/29/2017 at 10:45 AM 08/29/2017
Misc
Resolved
08/29/2017
-LOWER WATER METER TO FINISH GRADE. MAKE SURE METER IS 14"-18" FROM THE LID. -INSTALL FINAL GRADE, SOD, DOWNSPOUTS, SPLASHBLOCKS.
Documents & Images
Date Uploaded File Type Document Name
01/17/2017 Receipt Receipt for transaction: 2017-000149
01/17/2017 Letter Codes Building Permit
01/17/2017 Plot Plan DOC011717-005
01/25/2017 Engineer Report/Study DOC012517-002
02/03/2017 Letter Inspection Summary
02/07/2017 Engineer Report/Study DOC020717-002
02/07/2017 Letter Inspection Summary
02/07/2017 Letter Stop Work Order
02/08/2017 Letter Inspection Summary
02/08/2017 Letter Stop Work Order
02/08/2017 Photograph 400 SE Weiss 1
02/08/2017 Photograph 400 SE Weiss 2
02/08/2017 Photograph 400 SE Weiss 3
02/08/2017 Photograph 400 SE Weiss 4
02/08/2017 Photograph 400 SE Weiss 5
02/09/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
02/28/2017 Letter Inspection Summary
05/24/2017 Letter Inspection Summary
05/26/2017 Letter Inspection Summary
06/02/2017 Letter Inspection Summary
06/02/2017 Letter Inspection Summary
06/13/2017 Letter Inspection Summary
06/16/2017 Letter Inspection Summary
06/27/2017 Letter PW-Daily Inspection Summary
06/29/2017 Letter PW-Daily Inspection Summary
08/21/2017 Letter Inspection Summary
08/23/2017 Letter Codes Temporary Certificate of Occupancy
08/29/2017 Letter Field Certificate of Occupancy
09/01/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home