Permit Application Status

PRRES20163072


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20163072
Building Permit - Residential
Final Completion
WILLEY KATHLEEN B
ALTERATION SINGLE FAMILY
REPLACING AND UPGRADING TO ENERGY EFFICIENT GAS FURNACE ( WAS A BOILER). ADDING ELEECTRICAL AND MORE ENERGY EFFICIENT FIXTURES THROUGHOUT HOME ***** UPDATE-2/9/17- REWIRING ENTIRE HOUSE WITH ELECTRICAL, PER MORNING STAR INDUSTRIES. JILL VAN BERKOM- 206-300-6751- JUST BOUGHT HOME
11/28/2016
11/28/2016
04/03/2017
Locations
Contacts
WILLEY KATHLEEN B, Address:510 NE MAIN ST  
JILL VANBERKOM, Address:510 NW MAIN ST, Phone:(206) 300-6751  
MORNING STAR INDUSTRIES, Address:16905 E COGAN RD, Phone:(816) 985-7091  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 11/28/2016 11/28/2016
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Add/Alter Single Family $30.00 $30.00 Paid 11/28/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Electrical Inspection - Residential Passed 2/9/2017 2/10/2017 02/10/2017
Rough Plumbing Inspection - Residential Partial 2/13/2017 02/13/2017
Misc
Corrective Action Required
02/13/2017
IPC 903; LSCO 7-408 PLUMBING VENT SYSTEM MUST BE EXTENDED THROUGH ROOF
Misc
Corrective Action Required
02/13/2017
PIPING AT WATER HEATER: - PROVIDE DOCUMENTATION THAT HOT SIDE TUBING IS LISTED FOR THE PURPOSE - TPR DOWN-PIPE DOES NOT EXTEND TO WITHIN 6" OF FLOOR
Final Inspection - Residential Failed 3/22/2017 3/22/2017 03/22/2017
Misc
Corrective Action Required
03/22/2017
-VENT KITCHEN SINK TO OUTDOOR -INSTALL CO&SMOKE DECTECTOR OUTSIDE THE BEDROOM -THE WASHER RECEPTACLE INSIDE THE BATHROOM SHALL BE GFCI-PROTECTED -REJOINT DISCONNECTED DUCT NEAR THE FURNACE -SHALL CONNECT TOGETHER ALL DUCT JOINTS WITH MIN. 3 SCREWS AND TAPE ALL JOINTS WITH APPROVED TAPE OR SEALING COMPOUND -THE GAS CONNECTOR SHALL NOT PASS THROUGH THE FLOOR. THE GAS SHUT OFF VALVE FOR THE RANGE SHALL BE ON THE SAME LEVEL AS THE RANGE. SHALL EXTEND THE GAS PIPING FOR THE RANGE TO ABOVE KITCHEN FLOOR. GAS PIPING SHALL BE RETESTED FOR LEAKAGE. -PROVIDE MIN. SIX INCHES CLEARANCE FROM THE PEX LINES TO THE WATER HEATER FLUE CONNECTOR -INSTALL MAX. 20 AMP CUTLER HAMMER APPROVED BREAKER FOR AC UNIT -CIRCUIT SUPPLYING THE BEDROOM OUTLETS, INCLUDING THE SMOKE ALARM CIRCUIT MUST BE AFCI -SECURE LFNC RACEWAY WITHIN 12" OF THE AC DISCONNECT -SEAL EXTERIOR WALL PENETRATION OF AC LINE
Final Inspection - Residential Passed 3/31/2017 3/31/2017 03/31/2017
Misc
Resolved
03/31/2017
-VENT KITCHEN SINK TO OUTDOOR -INSTALL CO&SMOKE DECTECTOR OUTSIDE THE BEDROOM -THE WASHER RECEPTACLE INSIDE THE BATHROOM SHALL BE GFCI-PROTECTED -REJOINT DISCONNECTED DUCT NEAR THE FURNACE -SHALL CONNECT TOGETHER ALL DUCT JOINTS WITH MIN. 3 SCREWS AND TAPE ALL JOINTS WITH APPROVED TAPE OR SEALING COMPOUND -THE GAS CONNECTOR SHALL NOT PASS THROUGH THE FLOOR. THE GAS SHUT OFF VALVE FOR THE RANGE SHALL BE ON THE SAME LEVEL AS THE RANGE. SHALL EXTEND THE GAS PIPING FOR THE RANGE TO ABOVE KITCHEN FLOOR. GAS PIPING SHALL BE RETESTED FOR LEAKAGE. -PROVIDE MIN. SIX INCHES CLEARANCE FROM THE PEX LINES TO THE WATER HEATER FLUE CONNECTOR -INSTALL MAX. 20 AMP CUTLER HAMMER APPROVED BREAKER FOR AC UNIT -CIRCUIT SUPPLYING THE BEDROOM OUTLETS, INCLUDING THE SMOKE ALARM CIRCUIT MUST BE AFCI -SECURE LFNC RACEWAY WITHIN 12" OF THE AC DISCONNECT -SEAL EXTERIOR WALL PENETRATION OF AC LINE
Documents & Images
Date Uploaded File Type Document Name
11/28/2016 Receipt Receipt for transaction: 2016-006961
11/28/2016 Letter Codes Building Permit
11/29/2016 Scope of Work DOC112916-001
02/13/2017 Letter Inspection Summary
03/22/2017 Letter Inspection Summary
03/31/2017 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home