Summary
PRRES20162861
Building Permit - Residential
Certificate of Occupancy
JOHNSTON RE HOLDINGS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY WITH COVERED DECK
11/03/2016
11/17/2016
09/22/2021
Locations
Contacts
JOHNSTON RE HOLDINGS LLC, Address:801 NE DEL LAGO CT  
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 11/08/2016 11/09/2016
Hector Soto Jr.
Plot Plan Review Approved 11/09/2016
Jonathon Smith
Plot Plan Review Rejected 11/07/2016 11/04/2016
Jonathon Smith
Plot Plan Review (P&D) Rejected 11/07/2016 11/04/2016
Hector Soto Jr.
DE Corps of Engineers
Corrective Action Required
11/04/2016

The plot plan is not to scale.
Corrective Action Required
11/04/2016

Revise the legal description to read 11th Plat, not 10th Plat.
Corrective Action Required
11/04/2016

The 13.93' distance labeled along the front property line is only to indicate the distance from the sanitary easement to the west property line. Use tic marks to clarify the limits of the measurement.
Corrective Action Required
11/04/2016

Label the front 30' building line.
Corrective Action Required
11/04/2016

Show and label the front 15' U/E.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $649.13 $649.13 Paid 11/17/2016
8331507-Sewer Connection Fee $360.00 $360.00 Paid 11/17/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 11/17/2016
Water Meter Fee $405.36 $405.36 Paid 11/17/2016
Right of Way Permit Fee $75.00 $75.00 Paid 11/17/2016
Valuation Fee New Single Family $137.91 $137.91 Paid 07/05/2017
$787.04
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Not Ready 11/18/2016 (2:30) 11/18/2016 11/18/2016
Misc
Corrective Action Required
11/18/2016
NO PRINTS ON SITE
Footing Inspection - Residential Passed 11/21/2016 (8:00) 11/21/2016 11/21/2016
Underslab Plumbing Inspection - Residential Passed 2/2/2017 2/2/2017 02/02/2017
Sewer Service Inspection - R Passed 5/2/2017 5/2/2017 05/02/2017
Electrical Service Inspection Passed 5/5/2017 5/5/2017 05/05/2017
Gas Piping Inspection - Residential Passed 5/5/2017 5/5/2017 05/05/2017
Gas Service Inspection - Residential Failed 5/5/2017 5/5/2017 05/05/2017
Misc
Corrective Action Required
05/05/2017
Pressure OK, but gas line not bonded.
Water Service Inspection - R Passed 5/5/2017 (11:30) 5/5/2017 05/05/2017
All Rough Inspection - Residential Failed 5/5/2017 5/5/2017 05/05/2017
Misc
Corrective Action Required
05/05/2017
-Install purlin-legs over garage. -R&R purlin-leg over master closet that is <45deg. -Nail corner studs. -Provide lateral bracing for ceiling joists. -Nail joist-hangers in basement. -Plans do not show the short-walls over the headers/LVL along perimeter of great room; also do not show the LVL crossing above the great room, which supports the roof. Resolution will likely require engineer report and/or alteration of plans. -Install straps at wall plates that are bored more than 50% for passage of plumbing. -Install electrical shielding plates at corners of stairs.
Gas Service Inspection - Residential Passed 5/15/2017 5/15/2017 05/15/2017
Misc
Resolved
05/15/2017
Pressure OK, but gas line not bonded.
All Rough Inspection - Residential Failed 5/15/2017 5/15/2017 05/15/2017
Misc
Corrective Action Required
05/05/2017
-Plans do not show the short-walls over the headers/LVL along perimeter of great room; also do not show the LVL crossing above the great room, which supports the roof. Resolution will likely require engineer report and/or alteration of plans. -Install straps at wall plates that are bored more than 50% for passage of plumbing. okay to insulate
Piers/Caissons Inspection - Residential Passed 5/15/2017 5/15/2017 05/15/2017
All Rough Inspection - Residential Failed 6/2/2017 6/2/2017 06/02/2017
Misc
Corrective Action Required
05/15/2017
-Plans do not show the short-walls over the headers/LVL along perimeter of great room; also do not show the LVL crossing above the great room, which supports the roof. Resolution will likely require engineer report and/or alteration of plans. okay to insulate
All Rough Inspection - Residential Not Ready 8/11/2017 8/11/2017 08/11/2017
Misc
Corrective Action Required
06/02/2017
-NO ACCESS TO INSPECT BASEMENT
All Rough Inspection - Residential Not Ready 8/14/2017 8/14/2017 08/14/2017
Misc
Corrective Action Required
08/11/2017
-NO WORK BEING DONE IN BASEMENT
All Rough Inspection - Residential Passed 8/15/2017 8/15/2017 08/15/2017
Misc
Resolved
08/15/2017
-NO WORK BEING DONE IN BASEMENT
Driveway Inspection Partial 9/15/2017 9/15/2017 at 10:05 AM 09/15/2017
Informational
09/15/2017
John DiMauro 09/15/2017 10:57 AM Forms are up and rock is compacted.
Driveway Inspection Passed 9/18/2017 at 9:15 AM 09/18/2017
Sidewalk Inspection Partial 12/6/2017 12/6/2017 at 10:15 AM 12/06/2017
PW-Misc
Informational
12/06/2017
Brice Lawson 12/06/2017 10:26 AM The sidewalk forms are set. The rock has been compacted. It appears that the sidewalk is formed to the edge of the property. There is no way to know for sure as there is no curb show showing the corner of the lot. I let Gary know that the temperatures are going to be low and the sidewalk needs to be covered with blankets.
Occupancy Inspection - Codes Residential Not Ready 12/12/2017 at 10:51 AM 12/12/2017
Occupancy Inspection - Codes Residential Failed 12/14/2017 12/14/2017 at 11:30 AM 12/14/2017
Misc
Corrective Action Required
12/14/2017
-OBTAIN IRRIGATION PERMIT -REMOVE CONSTRUCTION DEBRIS FROM LOT TO WEST -FRONT PORCH REQUIRES HANDRAIL -CAP SEWER CLEANOUT AND BRING TO GRADE -WATER METER REQUIRED TO BE 14-18 INCHES FROM THE LID -GARAGE DOOR REQUIRED TO BE SELF CLOSING
Occupancy Inspection - Codes Residential Temporary C of O 12/15/2017 12/15/2017 12/15/2017
Misc
Corrective Action Required
12/14/2017
-OBTAIN IRRIGATION PERMIT -REMOVE CONSTRUCTION DEBRIS FROM LOT TO WEST -CAP SEWER CLEANOUT AND BRING TO GRADE -WATER METER REQUIRED TO BE 14-18 INCHES FROM lid to lid
Sidewalk Inspection Passed 12/13/2017 at 12:35 PM 01/05/2018
PW-Misc
Informational
01/05/2018
Brice Lawson 01/05/2018 12:50 PM The sidewalk has been installed. The cross slope was spot checked and it was below 2.0%.
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
-OBTAIN IRRIGATION PERMIT -REMOVE CONSTRUCTION DEBRIS FROM LOT TO WEST -CAP SEWER CLEANOUT AND BRING TO GRADE -WATER METER REQUIRED TO BE 14-18 INCHES FROM lid to lid
Documents & Images
Date Uploaded File Type Document Name
11/17/2016 Receipt Receipt for transaction: 2016-006869
11/17/2016 Letter Codes Building Permit
11/17/2016 Plot Plan DOC111716-005
11/18/2016 Letter Inspection Summary
11/21/2016 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
05/02/2017 Letter Inspection Summary
05/05/2017 Letter Inspection Summary
05/15/2017 Letter Inspection Summary
06/02/2017 Letter Inspection Summary
07/05/2017 Letter Codes Building Permit
07/05/2017 Receipt Receipt for transaction: 2017-004639
08/07/2017 Letter 3333 sw Jessie
08/14/2017 Letter Inspection Summary
08/15/2017 Letter Inspection Summary
09/15/2017 Letter DE-Daily Inspection Summary
09/18/2017 Letter DE-Daily Inspection Summary
12/06/2017 Letter DE-Daily Inspection Summary
12/12/2017 Letter Inspection Summary
12/12/2017 Letter Inspection Summary
12/14/2017 Letter Inspection Summary
12/15/2017 Letter Codes Temporary Certificate of Occupancy
01/05/2018 Letter DE-Daily Inspection Summary
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home