Permit Application Status

PRRES20162603


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162603
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK UNFINISHED BASEMENT
10/10/2016
10/13/2016
09/07/2018
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/12/2016 10/12/2016
James Fletchall
Plot Plan Review (P&D) Approved 10/12/2016 10/11/2016
Christina Stanton
Residential Plan Review Approved 10/12/2016 10/10/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,011.65 $1,011.65 Paid 10/13/2016
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/13/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/13/2016
Water Meter Fee $405.36 $405.36 Paid 10/13/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/8/2016 (11:30) 11/8/2016 at 11:20 AM 11/08/2016
Underslab Plumbing Inspection - Residential Passed 11/28/2016 11/28/2016 11/28/2016
Sewer Service Inspection - R Passed 11/28/2016 (1:00) 11/28/2016 11/28/2016
Water Service Inspection - R Passed 11/30/2016 (11:00) 11/30/2016 11/30/2016
All Rough Inspection - Residential Failed 3/13/2017 3/13/2017 03/13/2017
Misc
Corrective Action Required
03/13/2017
-NAIL ALL CHORDS OF THE GIRDERS PER PLANS -H-CLIP BOTH SIDES OF THE GIRDER TRUSSES -B-VENT CLEARANCE TO COMBUSTABLES IN THE GARAGE. -NAIL ALL CORNER STUDS 12" O.C. -UNCOVER FRAMING FOR COVERED PORCH
Gas Service Inspection - Residential Passed 3/13/2017 3/13/2017 03/13/2017
Gas Piping Inspection - Residential Passed 03/13/2017
Electrical Service Inspection Passed 3/13/2017 3/13/2017 03/13/2017
All Rough Inspection - Residential Failed 3/29/2017 3/29/2017 03/29/2017
Misc
Corrective Action Required
03/13/2017
-NAIL ALL CHORDS OF THE GIRDERS PER PLANS **2ND FL GIRDERS NOT NAILED PROPERLY; COMPLETE INSTALLING THE HANGER THAT CONNECT GIRDER TO GIRDER NEAR DUCT CHASE -H-CLIP BOTH SIDES OF THE GIRDER TRUSSES **2ND FL
All Rough Inspection - Residential Passed 3/31/2017 3/31/2017 03/31/2017
Misc
Resolved
03/31/2017
-NAIL ALL CHORDS OF THE GIRDERS PER PLANS **2ND FL GIRDERS NOT NAILED PROPERLY; COMPLETE INSTALLING THE HANGER THAT CONNECT GIRDER TO GIRDER NEAR DUCT CHASE -H-CLIP BOTH SIDES OF THE GIRDER TRUSSES **2ND FL
Sidewalk Inspection Partial 4/24/2017 4/24/2017 04/24/2017
Informational
04/24/2017
Tom Chandler 04/24/2017 4:21 PM Inspected forms only.
Sidewalk Inspection Passed 4/28/2017 04/27/2017
Informational
04/27/2017
Tom Chandler 04/27/2017 10:04 AM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Not Ready 6/2/2017 6/2/2017 06/02/2017
Occupancy Inspection - Codes Residential Not Ready 6/13/2017 6/13/2017 06/13/2017
Misc
Corrective Action Required
06/13/2017
CALL FOR INSPECTION ONCE WORK IS COMPLETE
Occupancy Inspection - Codes Residential Failed 6/14/2017 6/14/2017 06/14/2017
Misc
Corrective Action Required
06/13/2017
-OBTAIN IRRIGATION PERMIT -RE-GRADE REAR OF THE HOUSE, REQUIRED TO HAVE MINIMUM 6" CLEARANCE FROM SIDING TO GRADE AND 6" OF FALL AWAY FROM THE FOUNDATION WITHIN THE FIRST 10' -MAX FUSE FOR AC IS 40 AMP -INSTALL SECURITY SCREWS BOTH BACK DOORS.
Occupancy Inspection - Codes Residential Temporary C of O 06/14/2017
Misc
Corrective Action Required
06/14/2017
-OBTAIN IRRIGATION PERMIT -RE-GRADE REAR OF THE HOUSE, REQUIRED TO HAVE MINIMUM 6" CLEARANCE FROM SIDING TO GRADE AND 6" OF FALL AWAY FROM THE FOUNDATION WITHIN THE FIRST 10'
Occupancy Inspection - Codes Residential Failed 11/15/2017 11/15/2017 at 8:30 AM 11/15/2017
Misc
Corrective Action Required
06/14/2017
-OBTAIN IRRIGATION PERMIT -RE-GRADE REAR OF THE HOUSE, REQUIRED TO HAVE MINIMUM 6" CLEARANCE FROM SIDING TO GRADE AND 6" OF FALL AWAY FROM THE FOUNDATION WITHIN THE FIRST 10' INSTALLED ROCK AT THE REAR, CREATED A POND AND STILL DOES NOT HAVE 6" CLEARANCE FROM GRADE. DOES NOT HAVE 6" GREADE AWAY FROM THE FOUNDATION. RE-INSPECTION FEE
Occupancy Inspection - Codes Residential Full C of O 9/7/2018 09/07/2018
Misc
Resolved
09/07/2018
-OBTAIN IRRIGATION PERMIT -RE-GRADE REAR OF THE HOUSE, REQUIRED TO HAVE MINIMUM 6" CLEARANCE FROM SIDING TO GRADE AND 6" OF FALL AWAY FROM THE FOUNDATION WITHIN THE FIRST 10' INSTALLED ROCK AT THE REAR, CREATED A POND AND STILL DOES NOT HAVE 6" CLEARANCE FROM GRADE. DOES NOT HAVE 6" GREADE AWAY FROM THE FOUNDATION. RE-INSPECTION FEE
Documents & Images
Date Uploaded File Type Document Name
10/13/2016 Receipt Receipt for transaction: 2016-006380
10/13/2016 Letter Codes Building Permit
10/14/2016 Plot Plan DOC101416-006
11/04/2016 Engineer Report/Study DOC110416-003
11/08/2016 Letter Inspection Summary
11/10/2016 Engineer Report/Study DOC111016-002
11/28/2016 Letter Inspection Summary
11/28/2016 Letter Inspection Summary
03/13/2017 Letter Inspection Summary
03/29/2017 Letter Inspection Summary
03/31/2017 Letter Inspection Summary
04/27/2017 Letter PW-Daily Inspection Summary
06/02/2017 Letter Inspection Summary
06/13/2017 Letter Inspection Summary
06/14/2017 Letter Inspection Summary
06/14/2017 Letter Codes Temporary Certificate of Occupancy
11/15/2017 Letter Inspection Summary
11/15/2017 Letter Re-Inspection Fee
09/07/2018 Letter Field Certificate of Occupancy
09/10/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home