Summary
PRRES20161624
Building Permit - Residential
Certificate of Occupancy
JOHNSTON RE HOLDINGS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT
07/06/2016
08/05/2016
05/26/2017
Locations
Contacts
JOHNSTON RE HOLDINGS LLC, Address:801 NE DEL LAGO CT  
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/11/2016
Jonathon Hilton
Plot Plan Review Rejected 07/08/2016 07/08/2016
James Fletchall
Plot Plan Review (P&D) Approved 07/08/2016 07/07/2016
Ron Seyl
Residential Plan Review Approved 07/08/2016 07/06/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $642.74 $642.74 Paid 08/05/2016
Right of Way Permit Fee $75.00 $75.00 Paid 08/05/2016
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/05/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 08/05/2016
Water Meter Fee $405.36 $405.36 Paid 08/05/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/11/2016 (11:00) 8/11/2016 08/11/2016
Erosion Control Inspection Residential Failed 09/26/2016
Misc
Corrective Action Required
09/26/2016
INSTALL EROSION CONTROL AND CLEAN STREET.
Underslab Plumbing Inspection - Residential Passed 9/26/2016 9/26/2016 09/26/2016
Piers/Caissons Inspection - Residential Passed 11/8/2016 (9:30) 11/8/2016 at 10:10 AM 11/08/2016
Sewer Service Inspection - R Passed 12/29/2016 (9:30) 12/29/2016 12/29/2016
Water Service Inspection - R Partial 12/30/2016 (10:30) 12/30/2016 12/29/2016
Water Service Inspection - R Passed 12/30/2016
All Rough Inspection - Residential Failed 12/30/2016 12/30/2016 12/30/2016
Misc
Corrective Action Required
12/30/2016
-INSTALL STUD SHOES FOR OVERDRILLED STUDS FOR PLUMBING, FIREPLACE AND LAUNDRY. -INSTALL STRAPS FOR OVERDRILLED TOP PLATES AT PLUMBING THROUGHOUT, 4 NAILS EACH SIDE. -COMPLETE MASTER PLUMBING VENT. -FLASH ALL PLUMBING VENTS. -SECURITY BLOCK REAR DOOR. -GARAGE PORTAL: INSTALL STRAPS PER DETAIL, SPLICED IN THE SHEATHING MUST BE WITHIN 24" OF THE MID HEIGHT OF THE PORTAL AND BLOCKED AND NAILED. -INISTALL ANCHOR BOLTS NORTH GARAGE WALL. -SOUTH EAST HIP RAFTER SPLICED, HAVE ENGINEER ADDRESS. -PLANS CALL FOR 16d NAILS AT 4" O.C. IN THE EXTERIOR SILLS. -NAIL EXTERIOR CORNER STUDS 16" O.C. -NAIL RAFTERS TO CEILING JOISTS. -TERMINATE BATH VANITY AND FIREPLACE CONDUCTORS IN BOXES. DO NOT INSULATE
Gas Service Inspection - Residential Passed 12/30/2016
Gas Piping Inspection - Residential Passed 12/30/2016
Electrical Service Inspection Failed 12/30/2016
Misc
Corrective Action Required
12/30/2016
GROUND TO COPPER WATER LINE
All Rough Inspection - Residential Passed 1/24/2017 1/24/2017 01/24/2017
Misc
Resolved
01/24/2017
-INSTALL STUD SHOES FOR OVERDRILLED STUDS FOR PLUMBING, FIREPLACE AND LAUNDRY. -INSTALL STRAPS FOR OVERDRILLED TOP PLATES AT PLUMBING THROUGHOUT, 4 NAILS EACH SIDE. -COMPLETE MASTER PLUMBING VENT. -FLASH ALL PLUMBING VENTS. -SECURITY BLOCK REAR DOOR. -GARAGE PORTAL: INSTALL STRAPS PER DETAIL, SPLICED IN THE SHEATHING MUST BE WITHIN 24" OF THE MID HEIGHT OF THE PORTAL AND BLOCKED AND NAILED. -INISTALL ANCHOR BOLTS NORTH GARAGE WALL. -SOUTH EAST HIP RAFTER SPLICED, HAVE ENGINEER ADDRESS. -PLANS CALL FOR 16d NAILS AT 4" O.C. IN THE EXTERIOR SILLS. -NAIL EXTERIOR CORNER STUDS 16" O.C. -NAIL RAFTERS TO CEILING JOISTS. -TERMINATE BATH VANITY AND FIREPLACE CONDUCTORS IN BOXES. DO NOT INSULATE
Electrical Service Inspection Not Ready 3/7/2017 3/7/2017 03/07/2017
Misc
Corrective Action Required
12/30/2016
GROUND TO COPPER WATER LINE no lock box number provided. house is locked.
Electrical Service Inspection Not Ready 3/15/2017 3/15/2017 03/15/2017
Misc
Corrective Action Required
03/07/2017
GROUND TO COPPER WATER LINE SPRAYING PAINT INSIDE, CANNOT ACCESS TO INSPECT
Electrical Service Inspection Passed 3/24/2017 3/24/2017 03/24/2017
Misc
Resolved
03/24/2017
GROUND TO COPPER WATER LINE SPRAYING PAINT INSIDE, CANNOT ACCESS TO INSPECT
Driveway Inspection Passed 3/28/2017 3/28/2017 03/28/2017
PW-Misc
Informational
03/28/2017
John DiMauro 03/28/2017 2:50 PM Pre-pour inspection. Forms are up and rock is compacted.
Sidewalk Inspection Partial 5/17/2017 05/17/2017
PW-Misc
Informational
05/17/2017
Brice Lawson 05/17/2017 2:52 PM The sidewalk forms have been set at less than 2% cross slope. The rock has been compacted.
Occupancy Inspection - Codes Residential Failed 5/23/2017 5/23/2017 05/23/2017
Misc
Corrective Action Required
05/23/2017
1. Final grade, sod. 2. Garage to be self closing. 3. Install 4 three inch screws rear door at the strike side and 2 per hinge. 4. Basement bath GFCI not re setting. 5. Secure SE cable within 12" of the panel. 6. Anchor columns in basement. 7. Obtain final sidewalk approval.
Sidewalk Inspection Passed 5/24/2017 05/23/2017
PW-Misc
Informational
05/17/2017
Brice Lawson 05/17/2017 2:52 PM The sidewalk forms have been set at less than 2% cross slope. The rock has been compacted.
PW-Misc
Informational
05/23/2017
Brice Lawson 05/23/2017 2:48 PM The 5' sidewalk has been installed and passed inspection. It appears that the white curing compound was not applied to the sidewalk. I informed Bill Kenny that this is a requirement on new driveways and sidewalks.
Occupancy Inspection - Codes Residential Temporary C of O 5/24/2017 5/24/2017 05/24/2017
Misc
Corrective Action Required
05/23/2017
1. Final grade, sod
Occupancy Inspection - Codes Residential Full C of O 5/26/2017 5/26/2017 05/26/2017
Misc
Resolved
05/26/2017
1. Final grade, sod
Documents & Images
Date Uploaded File Type Document Name
08/05/2016 Receipt Receipt for transaction: 2016-005270
08/05/2016 Letter Codes Building Permit
08/08/2016 Plot Plan DOC080816
08/11/2016 Letter Inspection Summary
09/26/2016 Letter Inspection Summary
11/08/2016 Letter Inspection Summary
12/29/2016 Letter Inspection Summary
12/30/2016 Letter Inspection Summary
12/30/2016 Letter Inspection Summary
01/24/2017 Letter Inspection Summary
01/27/2017 Engineer Report/Study DOC012717
03/07/2017 Letter Inspection Summary
03/15/2017 Letter Inspection Summary
03/24/2017 Letter Inspection Summary
03/28/2017 Letter PW-Daily Inspection Summary
05/17/2017 Letter PW-Daily Inspection Summary
05/23/2017 Letter Inspection Summary
05/23/2017 Letter PW-Daily Inspection Summary
05/24/2017 Letter Codes Temporary Certificate of Occupancy
05/26/2017 Letter Field Certificate of Occupancy
07/12/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home