Permit Application Status

PRRES20161381


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20161381
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY
06/09/2016
06/13/2016
09/11/2017
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 06/13/2016 06/13/2016
Jonathon Hilton
Plot Plan Review Approved 06/13/2016 06/13/2016
James Fletchall
Residential Plan Review Approved 06/13/2016 06/10/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,018.99 $1,018.99 Paid 06/13/2016
Right of Way Permit Fee $75.00 $75.00 Paid 06/13/2016
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/13/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 06/13/2016
Water Meter Fee $377.18 $377.18 Paid 06/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 8/5/2016 (9:30) 8/5/2016 08/05/2016
Misc
Corrective Action Required
08/05/2016
FOOTING IS REQUIRED TO BE 8" DEEP. MEASSURED 5.5 INCHES AT MOST LOCATIONS.
Footing Inspection - Residential Passed 8/5/2016 08/05/2016
Misc
Corrective Action Required
08/05/2016
FOOTING IS REQUIRED TO BE 8" DEEP. MEASSURED 5.5 INCHES AT MOST LOCATIONS.
Water Service Inspection - R Passed 8/11/2016 (11:00) 8/11/2016 08/11/2016
Sewer Service Inspection - R Passed 8/12/2016 (10:00) 8/12/2016 08/12/2016
Underslab Plumbing Inspection - Residential Passed 8/25/2016 08/25/2016
Piers/Caissons Inspection - Residential Passed 8/31/2016 (1:00) 8/31/2016 08/31/2016
Driveway Inspection Partial 11/8/2016 11/09/2016
All Rough Inspection - Residential Failed 12/8/2016 12/8/2016 12/08/2016
Misc
Corrective Action Required
12/08/2016
-REPLACE CUT I JOIST IN BASEMENT EAST END, CUT FOR PLUMBING -SECURITY BLOCK REAR DOOR -NM CONDUCTORS 6 FEET FROM ATTIC ACCESS, NEED TO BE SECURED TO THE RUNNING BOARD IN ORDER TO PROTECT THE CONDUCTORS. -INSTALL STUD SUPPORT FOR GIRDER TRUSS MASTER CLOSET AT WEST END AND NAIL THE TOP CHORDS OF THE GIRDER. OKAY TO INSULATE
Electrical Service Inspection Passed 12/8/2016 12/8/2016 12/08/2016
Gas Service Inspection - Residential Failed 12/8/2016 12/8/2016 12/08/2016
Misc
Corrective Action Required
12/08/2016
NO PRESSURE
Driveway Inspection Passed 11/16/2016 12/21/2016
All Rough Inspection - Residential Failed 12/22/2016 12/22/2016 12/22/2016
Misc
Corrective Action Required
12/08/2016
-SECURITY BLOCK REAR DOOR **INSTALL BLOCKING AT STRIKE PLATE SIDE (AT STRIKE PLATE HEIGHT) AND FILL IN GAPS AT HINGES -HAVE THE ELECTRICIAN REWIRE THE HOUSE. THE HOUSE WIRINGS WERE VANDALIZED OKAY TO INSULATE
Gas Service Inspection - Residential Passed 12/22/2016 12/22/2016 12/22/2016
Misc
Resolved
12/22/2016
NO PRESSURE
All Rough Inspection - Residential Passed 1/10/2017 1/10/2017 01/10/2017
Misc
Resolved
01/10/2017
-SECURITY BLOCK REAR DOOR **INSTALL BLOCKING AT STRIKE PLATE SIDE (AT STRIKE PLATE HEIGHT) AND FILL IN GAPS AT HINGES -HAVE THE ELECTRICIAN REWIRE THE HOUSE. THE HOUSE WIRINGS WERE VANDALIZED OKAY TO INSULATE
Sidewalk Inspection Partial 3/17/2017 3/17/2017 03/20/2017
PW-Misc
Corrective Action Required
03/20/2017
Pass forms
Sidewalk Inspection Passed 3/21/2017 at 8:00 AM 04/14/2017
PW-Misc
Corrective Action Required
03/20/2017
Pass forms
Occupancy Inspection - Codes Residential Not Ready 7/19/2017 7/19/2017 07/19/2017
Misc
Corrective Action Required
07/19/2017
NO INSPECTION - EROSION CONTROL NEEDED
Gas Piping Inspection - Residential Not Ready 7/19/2017 7/19/2017 07/19/2017
Misc
Corrective Action Required
07/19/2017
NO INSPECTION - EROSION CONTROL NEEDED
Erosion Control Inspection Residential Failed 7/19/2017 07/19/2017
Erosion Control Inspection Residential Failed 07/21/2017
Misc
Corrective Action Required
07/21/2017
PROTECT EAST SIDE
Occupancy Inspection - Codes Residential Not Ready 7/21/2017 7/21/2017 07/21/2017
Misc
Corrective Action Required
07/19/2017
NO INSPECTION - EROSION CONTROL NEEDED EAST SIDE
Occupancy Inspection - Codes Residential Failed 7/25/2017 7/25/2017 07/25/2017
Misc
Resolved
07/25/2017
NO INSPECTION - EROSION CONTROL NEEDED EAST SIDE
Misc
Corrective Action Required
07/25/2017
1. Final grade, sod, splash blocks, etc. 2. Protect I-joists in basement. 3. Repair jacuzzi tub - currently can only be turned on/off by tripping/resetting the GFI receptacle near the water closet. 4. Security screws at rear door. 5. Guardrails needed at front porch: at west side, and at west end of north side.
Occupancy Inspection - Codes Residential Temporary C of O 7/27/2017 7/27/2017 07/27/2017
Misc
Corrective Action Required
07/25/2017
1. Final grade, sod, splash blocks, etc. 2. Guardrails needed at front porch, at west end of north side; or raise final grade.
Occupancy Inspection - Codes Residential Temporary C of O 8/23/2017 8/23/2017 at 11:00 AM 08/23/2017
Misc
Corrective Action Required
07/27/2017
1. Install splash blocks. 2. Guardrails needed at front porch, at west end of north side; or raise final grade.
Occupancy Inspection - Codes Residential Full C of O 09/11/2017
Misc
Resolved
09/11/2017
1. Install splash blocks. 2. Guardrails needed at front porch, at west end of north side; or raise final grade.
Documents & Images
Date Uploaded File Type Document Name
06/13/2016 Receipt Receipt for transaction: 2016-003657
06/13/2016 Letter Codes Building Permit
06/14/2016 Plot Plan DOC061416-011
08/11/2016 Letter Inspection Summary
08/12/2016 Letter Inspection Summary
08/25/2016 Letter Inspection Summary
08/31/2016 Letter Inspection Summary
12/08/2016 Letter Inspection Summary
12/21/2016 Letter Inspection Summary
12/22/2016 Letter Inspection Summary
01/10/2017 Letter Inspection Summary
03/20/2017 Letter PW-Daily Inspection Summary
04/14/2017 Letter PW-Daily Inspection Summary
07/19/2017 Letter Inspection Summary
07/21/2017 Letter Inspection Summary
07/25/2017 Letter Inspection Summary
07/27/2017 Letter Codes Temporary Certificate of Occupancy
08/23/2017 Letter Codes Temporary Certificate of Occupancy
09/11/2017 Letter Field Certificate of Occupancy
09/14/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home