Summary
PRRES20160937
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK ROOF TRUSS/FLOOR SYSTEM
04/22/2016
04/26/2016
11/28/2016
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/26/2016
Jonathon Hilton
Plot Plan Review Rejected 04/26/2016
James Fletchall
Residential Plan Review Approved 04/26/2016 04/26/2016
Jonathon Hilton
Plot Plan Review (P&D) Approved 04/25/2016
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,011.06 $1,011.06 Paid 04/26/2016
Right of Way Permit Fee $75.00 $75.00 Paid 04/26/2016
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/26/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 04/26/2016
Water Meter Fee $377.18 $377.18 Paid 04/26/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/4/2016 (11:30) 5/4/2016 05/04/2016
Sewer Service Inspection - R Passed 5/18/2016 (9:30) 5/18/2016 05/18/2016
Water Service Inspection - R Passed 5/18/2016 (2:15) 5/18/2016 05/18/2016
Underslab Plumbing Inspection - Residential Passed 6/2/2016 6/2/2016 06/02/2016
Driveway Inspection Passed 7/15/2016 07/21/2016
PW-Misc
Informational
07/21/2016
Tom Chandler 07/21/2016 9:05 AM Driveway is complete and passed inspection.
All Rough Inspection - Residential Failed 8/3/2016 8/3/2016 08/03/2016
Misc
Corrective Action Required
08/03/2016
-REAR DINETTE WALL DOES NOT MEET THE MINIMUM PANEL WIDTH FOR BRACED WALL. INSTALL HOLD DOWNS PER CODE OR HAVE ENGINEER ADDRESS. -ALL CORNER ROOF TRUSSES DONT HAVE H-CLIPS -GIRDER TRUSS OVER KITCHEN NEEDS TWO H CLIPS PER END. -INSTALL STUD SUPPORT SOUTH END OF GIRDER TRUSS OVER KITCHEN AND SQUASH BLOCK IN THE BASEMENT. -MISSING SEVERAL TRUSS HANGERS THROUGHOUT, SEE ROOF TRUSS LAYOUT AND INSTALL ACCORDINGLY. -MASTER BED VAULT FIREBLOCKING USED REQUIRED TO BE MINIMUM 3/4" PLY OR 1/2" GYP. -FRONT ROOM FIRST FLOOR, BLOCK CANTILEVERS OR USE 2x4 TOP AND BOTTOM WHERE DUCT INSTALLED. -REAR DECK ATTACHED TO CANTILEVER, THIS MUST BE HEADERED OR INSTALL POSTS. -EXTERIOR CORNER STUDS MUST BE NAILED MINIMUM 12" WITH 16d NAILS. DO NOT INSULATE
Gas Service Inspection - Residential Failed 8/3/2016 8/3/2016 08/03/2016
Misc
Corrective Action Required
08/03/2016
ONLY ABOUT 1.5 FEET OF GAS PIPE ON PRESSURE AT THE FURNACE DUE TO SHUT OFF, AND LIKELY RUINED THE FURNACE REGULATOR.
Electrical Service Inspection Passed 8/3/2016 8/3/2016 08/03/2016
Gas Service Inspection - Residential Failed 8/9/2016 8/9/2016 08/09/2016
Misc
Corrective Action Required
08/03/2016
ONLY ABOUT 1.5 FEET OF GAS PIPE ON PRESSURE AT THE FURNACE DUE TO SHUT OFF, AND LIKELY RUINED THE FURNACE REGULATOR. **2ND INSPECTION, NO TEST PRESSURE AT ALL.***
All Rough Inspection - Residential Failed 8/9/2016 8/9/2016 08/09/2016
Misc
Corrective Action Required
08/03/2016
-MASTER BED VAULT FIREBLOCKING USED REQUIRED TO BE MINIMUM 3/4" PLY OR 1/2" GYP. -REAR DECK ATTACHED TO CANTILEVER, THIS MUST BE HEADERED OR INSTALL POSTS. OKAY INSULATE
All Rough Inspection - Residential Partial 8/12/2016 8/12/2016 08/12/2016
Misc
Corrective Action Required
08/09/2016
-REAR DECK ATTACHED TO CANTILEVER, THIS MUST BE HEADERED OR INSTALL POSTS. WILL CHECK AT FINAL. OKAY TO ROCK
Sidewalk Inspection Partial 10/18/2016 10/19/2016
Sidewalk Inspection Passed 10/26/2016 10/31/2016
Gas Service Inspection - Residential Passed 10/31/2016 10/31/2016 10/31/2016
Misc
Resolved
10/31/2016
ONLY ABOUT 1.5 FEET OF GAS PIPE ON PRESSURE AT THE FURNACE DUE TO SHUT OFF, AND LIKELY RUINED THE FURNACE REGULATOR. **2ND INSPECTION, NO TEST PRESSURE AT ALL.***
Occupancy Inspection - Codes Residential Failed 11/14/2016 11/14/2016 11/14/2016
Misc
Corrective Action Required
11/14/2016
flue clearance to combustible bsmt ceiling - deck header around boxout needs to be doubled.
Occupancy Inspection - Codes Residential Failed 11/15/2016 11/15/2016 11/15/2016
Misc
Corrective Action Required
11/14/2016
flue clearance to combustible bsmt ceiling - deck header around boxout needs to be doubled.
Occupancy Inspection - Codes Residential Temporary C of O 11/15/2016 11/15/2016
Misc
Corrective Action Required
11/15/2016
- deck header around boxout needs to be doubled.
Occupancy Inspection - Codes Residential Full C of O 11/28/2016 11/28/2016 11/28/2016
Misc
Resolved
11/28/2016
- deck header around boxout needs to be doubled.
Documents & Images
Date Uploaded File Type Document Name
04/26/2016 Receipt Receipt for transaction: 2016-001306
04/26/2016 Letter Codes Building Permit
04/26/2016 Plot Plan DOC042616-008
05/04/2016 Letter Inspection Summary
05/04/2016 Engineer Report/Study DOC050416-009
05/18/2016 Letter Inspection Summary
06/02/2016 Letter Inspection Summary
07/21/2016 Letter PW-Daily Inspection Summary
08/03/2016 Letter Inspection Summary
08/09/2016 Letter Inspection Summary
08/12/2016 Letter Inspection Summary
10/31/2016 Letter Inspection Summary
11/14/2016 Letter Inspection Summary
11/15/2016 Letter Inspection Summary
11/15/2016 Letter Codes Temporary Certificate of Occupancy
11/29/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home