Summary
PRRES20160711
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY WITH DECK
04/05/2016
04/08/2016
11/10/2016
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/07/2016 04/07/2016
James Fletchall
Plot Plan Review (P&D) Approved 04/07/2016 04/06/2016
Jennifer Thompson
Residential Plan Review Approved 04/07/2016 04/05/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $766.47 $766.47 Paid 04/08/2016
Right of Way Permit Fee $75.00 $75.00 Paid 04/08/2016
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/08/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 04/08/2016
Water Meter Fee $377.18 $377.18 Paid 04/08/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/21/2016 (1:30) 4/21/2016 04/21/2016
Sewer Service Inspection - R Passed 4/28/2016 (8:00) 4/28/2016 04/28/2016
Water Service Inspection - R Passed 4/29/2016 (11:30) 4/29/2016 04/29/2016
Underslab Plumbing Inspection - Residential Passed 5/4/2016 5/4/2016 05/04/2016
Driveway Inspection Partial 7/18/2016 07/18/2016
All Rough Inspection - Residential Failed 7/20/2016 7/20/2016 07/20/2016
Misc
Corrective Action Required
07/20/2016
-B VENT 1 INCH CLEARANCE TO COMBUSTABLE IN GARAGE. -FIREBLOCK GARAGE CHASE -LOOSE ANCHOR BOLTS IN GARAGE. REQUIRED TO HAVE MINIMUM 2 ANCHOR BOLTS PER GARAGE PORTAL. -NAIL GIRDER TRUSS IN GARAGE -SECURITY BLOCK BASEMENT WALKOUT DOOR -MID BEARING BEAM IN BASEMENT, MUST HAVE BEARING THE FULL WIDTH OF THE BEAM. -OVER BED 3 SE BASEMENT BED, HANGER FOR FJ 14 AND DOUBLE LVL. SOLID BLOCK PER LAYOUT AT SAME LOCATION. -CANTILEVER OVER FURNACE, SOLID BLOCK AND INSTALL HANGERS PER LAYOUT. -CANTILIVER FOR MASTER BATH, SOLID BLOCK AND INSULATE WATER SUPPLY LINES. -COMPLETE SUPPLY DUCT TO BEDROOM 2 FLEX ROOM. DO NOT INSULATE
Electrical Service Inspection Passed 07/20/2016
Gas Piping Inspection - Residential Passed 07/20/2016
Gas Service Inspection - Residential Passed 07/20/2016
Driveway Inspection Passed 7/25/2016 07/21/2016
PW-Misc
Informational
07/21/2016
Tom Chandler 07/21/2016 9:20 AM Driveway is complete and passed inspection.
All Rough Inspection - Residential Failed 7/29/2016 7/29/2016 07/29/2016
Misc
Corrective Action Required
07/20/2016
-FIREBLOCK GARAGE CHASE **FB GAPS. -THE SHORT SILL PLATE AT SW CORNER REQUIRED TO HAVE MINIMUM 2 ANCHOR BOLTS -OVER BED 3 SE BASEMENT BED, HANGER FOR FJ 14 AND DOUBLE LVL. **FIELD-MODIFIED HANGER? HAVE ENGINEER OK THAT OR INSTALL A PROPER ONE -OVER FURNACE AND INSTALL HANGERS PER LAYOUT. **INSTALL WEB FILLER AT DOUBLE TJI CONNECTION. THE HANGER INSTALLATION FOR THE REMAINING JOISTS IS WRONG. GET PROPER SIZE HANGERS FOR THE JOIST CONNECTIONS **OK TO INSULATE
All Rough Inspection - Residential Passed 8/15/2016 8/15/2016 08/15/2016
Misc
Resolved
08/15/2016
-FIREBLOCK GARAGE CHASE **FB GAPS. -THE SHORT SILL PLATE AT SW CORNER REQUIRED TO HAVE MINIMUM 2 ANCHOR BOLTS -OVER BED 3 SE BASEMENT BED, HANGER FOR FJ 14 AND DOUBLE LVL. **FIELD-MODIFIED HANGER? HAVE ENGINEER OK THAT OR INSTALL A PROPER ONE -OVER FURNACE AND INSTALL HANGERS PER LAYOUT. **INSTALL WEB FILLER AT DOUBLE TJI CONNECTION. THE HANGER INSTALLATION FOR THE REMAINING JOISTS IS WRONG. GET PROPER SIZE HANGERS FOR THE JOIST CONNECTIONS **OK TO INSULATE
Sidewalk Inspection Partial 9/29/2016 09/29/2016
Sidewalk Inspection Passed 10/6/2016 10/06/2016
Occupancy Inspection - Codes Residential Failed 10/20/2016 10/20/2016 10/20/2016
Misc
Corrective Action Required
10/20/2016
-BASEMENT BATH RECEPTACLE NOT RE SETTING -INSTALL FINALL GRADE, SOD
Occupancy Inspection - Codes Residential Temporary C of O 10/20/2016
Misc
Corrective Action Required
10/20/2016
-INSTALL FINALL GRADE, SOD
Occupancy Inspection - Codes Residential Full C of O 11/10/2016 11/10/2016 11/10/2016
Misc
Resolved
11/10/2016
-INSTALL FINALL GRADE, SOD
Documents & Images
Date Uploaded File Type Document Name
04/08/2016 Receipt Receipt for transaction: 2016-001047
04/08/2016 Letter Codes Building Permit
04/08/2016 Plot Plan DOC040816-011
04/13/2016 Engineer Report/Study DOC041316-003
04/21/2016 Letter Inspection Summary
04/28/2016 Letter Inspection Summary
04/29/2016 Letter Inspection Summary
07/20/2016 Letter Inspection Summary
07/21/2016 Letter PW-Daily Inspection Summary
07/29/2016 Letter Inspection Summary
08/15/2016 Letter Inspection Summary
10/20/2016 Letter Inspection Summary
10/20/2016 Letter Codes Temporary Certificate of Occupancy
11/10/2016 Letter Field Certificate of Occupancy
11/11/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home