Permit Application Status

PRRES20160496


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20160496
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK
03/11/2016
03/25/2016
09/22/2021
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/15/2016 03/25/2016
Jonathon Hilton
Plot Plan Review Approved 03/15/2016 03/15/2016
James Fletchall
Plot Plan Review (P&D) Approved 03/15/2016 03/14/2016
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,180.69 $1,180.69 Paid 03/25/2016
Right of Way Permit Fee $75.00 $75.00 Paid 03/25/2016
8331507-Sewer Connection Fee $600.00 $600.00 Paid 03/25/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 03/25/2016
Water Meter Fee $377.18 $377.18 Paid 03/25/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/29/2016 (11:15) 3/29/2016 03/29/2016
Sewer Service Inspection - R Passed 4/6/2016 (11:15) 4/6/2016 04/06/2016
Water Service Inspection - R Partial 04/06/2016
Underslab Plumbing Inspection - Residential Not Ready 4/7/2016 4/7/2016 04/07/2016
Misc
Informational
04/07/2016
PROVIDE ACCESS , NOT BACK FILLED. CAN NOT SEE PIPE. POST ADDRESS. INTERIOR DRAIN TILE DOES NOT EXTEND THE ENTIRE LENGTH OF THE BSMT.
Water Service Inspection - R Passed 4/8/2016 (11:00) 4/8/2016 04/08/2016
Underslab Plumbing Inspection - Residential Passed 4/12/2016 4/12/2016 04/12/2016
Misc
Resolved
04/12/2016
PROVIDE ACCESS , NOT BACK FILLED. CAN NOT SEE PIPE. POST ADDRESS. INTERIOR DRAIN TILE DOES NOT EXTEND THE ENTIRE LENGTH OF THE BSMT.
All Rough Inspection - Residential Failed 6/21/2016 6/21/2016 06/21/2016
Misc
Corrective Action Required
06/21/2016
-NAIL GARAGE PORTAL PER PLANS -INSTALL TRUSS HANGERS GARAGE PER PLANS -FIRESTOP THROUGHOUT PER CODE. MAKE SURE INSULATION IS TIGHT IF USED AS FIRESTOPING -NAIL ALL EXTERIOR CORNER STUDS 12" O.C. -REAR DINING WALL, FRAME PER DETAIL S4.0 -INSTALL HORZ. SECURITY BLOCK REAR DOOR -STRAP MID BEARING TOP PLATE 1ST FLOOR -H-CLIP TUSSES ABOVE 2ND FLOOR TUB -LATERAL BLOCKS BASEMENT FLOOR JOISTS, WHERE REMOVED FOR DUCT WORK, INSTALL 2X4 TOP AND BOTTOM CORD -VENT WATER HEATER (MAKE SURE UFFER IS ACCESSABLE AT FINAL) DO NOT INSULATE
Gas Service Inspection - Residential Passed 6/21/2016 6/21/2016 06/21/2016
Gas Piping Inspection - Residential Passed 06/21/2016
Electrical Service Inspection Failed 6/21/2016 6/21/2016 06/21/2016
Misc
Corrective Action Required
06/21/2016
GROUNDING ELECTRODE CONDUCTOR NOT CONNECTED TO UFFER
All Rough Inspection - Residential Failed 7/7/2016 7/7/2016 07/07/2016
Misc
Corrective Action Required
06/21/2016
-GARAGE PORTAL, SPLICE IN SHEATHING REQUIRESS HORZ. BLOCK AND NAILED 3" OC. -FIRESTOP THROUGHOUT PER CODE. MAKE SURE INSULATION IS TIGHT IF USED AS FIRESTOPING -VENT WATER HEATER (MAKE SURE UFFER IS ACCESSABLE AT FINAL) OKAY INSULATE
Electrical Service Inspection Passed 7/7/2016 7/7/2016 07/07/2016
Misc
Resolved
07/07/2016
GROUNDING ELECTRODE CONDUCTOR NOT CONNECTED TO UFFER
All Rough Inspection - Residential Partial 7/20/2016 7/20/2016 07/20/2016
Misc
Corrective Action Required
07/07/2016
-VENT WATER HEATER (MAKE SURE UFFER IS ACCESSABLE AT FINAL) OKAY TO SHEETROCK, WILL CHECK REMAINING ITEMS AT FINAL. NOTE, FOAM INSULATATION COVERED UFFER GROUND.
Driveway Inspection Passed 7/15/2016 07/21/2016
PW-Misc
Informational
07/21/2016
Tom Chandler 07/21/2016 9:10 AM Driveway is complete and passed inspection.
Sidewalk Inspection Partial 10/18/2016 10/19/2016
Sidewalk Inspection Passed 10/26/2016 10/31/2016
All Rough Inspection - Residential Passed 03/09/2017
Misc
Resolved
03/09/2017
-VENT WATER HEATER (MAKE SURE UFFER IS ACCESSABLE AT FINAL) OKAY TO SHEETROCK, WILL CHECK REMAINING ITEMS AT FINAL. NOTE, FOAM INSULATATION COVERED UFFER GROUND.
Occupancy Inspection - Codes Residential Temporary C of O 3/9/2017 3/9/2017 03/09/2017
Misc
Corrective Action Required
03/09/2017
-RAISE WATER METER TO FLUSH WITH GRADE. MAINTAIN METER-LID DISTANCE PER LS STANDARD -INSTALL SEWER CLEANOUT PLUG
Occupancy Inspection - Codes Residential Failed 7/20/2017 7/20/2017 07/20/2017
Misc
Corrective Action Required
03/09/2017
-INSTALL SEWER CLEANOUT PLUG **LOCATE AND MAKE ACCESSIBLE THE SEWER CLEANOUT
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
-INSTALL SEWER CLEANOUT PLUG **LOCATE AND MAKE ACCESSIBLE THE SEWER CLEANOUT
Documents & Images
Date Uploaded File Type Document Name
03/25/2016 Receipt Receipt for transaction: 2016-000856
03/25/2016 Letter Codes Building Permit
03/28/2016 Plot Plan DOC032816-001
03/29/2016 Letter Inspection Summary
04/06/2016 Letter Inspection Summary
04/07/2016 Letter Inspection Summary
04/08/2016 Letter Inspection Summary
04/12/2016 Letter Inspection Summary
06/21/2016 Letter Inspection Summary
07/07/2016 Letter Inspection Summary
07/20/2016 Letter Inspection Summary
07/21/2016 Letter PW-Daily Inspection Summary
03/09/2017 Letter Codes Temporary Certificate of Occupancy
07/20/2017 Letter Inspection Summary
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home