PRRES20152451
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - 2 STORY - UNFINISHED BASEMENT *ROOF & FLOOR TRUSSES
10/21/2015
10/30/2015
09/22/2021
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/29/2015
James Fletchall
Residential Plan Review Approved 10/23/2015 10/22/2015
Tara Mitchell
Plot Plan Review (P&D) Approved 10/22/2015
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,118.81 $1,118.81 Paid 10/30/2015
Right of Way Permit Fee $75.00 $75.00 Paid 10/30/2015
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/30/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 10/30/2015
Water Meter Fee $377.18 $377.18 Paid 10/30/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/20/2015 (11:30) 11/20/2015 at 12:00 AM 11/20/2015
Sewer Service Inspection - R Passed 12/1/2015 at 12:00 AM 12/01/2015
Water Service Inspection - R Passed 12/2/2015 (1:00) 12/2/2015 at 12:00 AM 12/02/2015
Underslab Plumbing Inspection - Residential Not Ready 12/23/2015 12/23/2015 12/22/2015
Misc
Corrective Action Required
12/22/2015
DENIED FOR HAVING INCORRECT SUB-CONTRACTORS LISTED ON THE PERMIT APPLICATION.
Underslab Plumbing Inspection - Residential Passed 1/6/2016 1/6/2016 01/06/2016
Misc
Corrective Action Required
12/22/2015
DENIED FOR HAVING INCORRECT SUB-CONTRACTORS LISTED ON THE PERMIT APPLICATION.
Driveway Inspection Partial 4/21/2016 04/21/2016
Driveway Inspection Passed 4/28/2016 04/27/2016
PW-Misc
Informational
04/27/2016
Driveway approach is complete.Tom Chandler 04/27/2016 9:59 AM
All Rough Inspection - Residential Failed 5/4/2016 5/4/2016 05/04/2016
Misc
Corrective Action Required
05/04/2016
-NAIL SIDING PER MANUFACTURER. RE NAIL ANY NAILS OVERDRIVEN 1/8TH INCH. -FIREBLOCK AND FIRESTOP THROUGHOUT -ANCHOR GARAGE COLUMN WITH APPROVED ANCHOR -BLOCK POINT LOAD NEXT TO STAIRS IN BASEMENT -FUR DOWN BASEMENT FOR GYP BOARD -SHIM ALL CRIPPLE STUDS FOR FULL HEADER BEARING -INSTALL ADDITIONAL JOIST IN REAR BASEMENT WHERE JOIST SPACED 24" -REPAIR BRACED WALL MASTER BED -BLOCK KITCHEN ISLAND 48" O.C. PER PLANS -SPLICES IN GARAGE PORTAL SHEATHING TO BE WITHIN 24" MID HEIGHT -SOLID BLOCK FIREPLACE CANTILEVER DO NOT INSULATE
Gas Service Inspection - Residential Passed 5/4/2016 5/4/2016 05/04/2016
Gas Piping Inspection - Residential Passed 05/04/2016
Electrical Service Inspection Passed 5/4/2016 5/4/2016 05/04/2016
All Rough Inspection - Residential Not Ready 5/13/2016 5/13/2016 05/13/2016
Misc
Corrective Action Required
05/04/2016
-NAIL SIDING PER MANUFACTURER. RE NAIL ANY NAILS OVERDRIVEN 1/8TH INCH. -FIREBLOCK AND FIRESTOP THROUGHOUT, REAR WALL CHASE BOTH SIDES OF GREAT ROOM, FLUE CHASE LOOSE INSULATION NOT APPROVED, DEAD SPACE REAR OF FRIG BLOCK ENTIRE CHASE VERT. TO HORIZ. -ANCHOR GARAGE COLUMN WITH APPROVED ANCHOR, TAP CONS INCORRECT -FUR DOWN BASEMENT FOR GYP BOARD -INSTALL ADDITIONAL JOIST IN REAR BASEMENT WHERE JOIST SPACED 24" DO NOT INSULATE
All Rough Inspection - Residential Passed 5/19/2016 5/19/2016 05/19/2016
Misc
Resolved
05/19/2016
-NAIL SIDING PER MANUFACTURER. RE NAIL ANY NAILS OVERDRIVEN 1/8TH INCH. -FIREBLOCK AND FIRESTOP THROUGHOUT, REAR WALL CHASE BOTH SIDES OF GREAT ROOM, FLUE CHASE LOOSE INSULATION NOT APPROVED, DEAD SPACE REAR OF FRIG BLOCK ENTIRE CHASE VERT. TO HORIZ. -ANCHOR GARAGE COLUMN WITH APPROVED ANCHOR, TAP CONS INCORRECT -FUR DOWN BASEMENT FOR GYP BOARD -INSTALL ADDITIONAL JOIST IN REAR BASEMENT WHERE JOIST SPACED 24" DO NOT INSULATE
Occupancy Inspection - Codes Residential Failed 10/25/2016 10/25/2016
Corrective Action Required
10/25/2016
-INSTALL GARAGE DOOR SELF CLOSER -OBTAIN IRRIGATION PERMIT
Occupancy Inspection - Codes Residential Temporary C of O 10/26/2016 10/26/2016 10/26/2016
Misc
Corrective Action Required
10/26/2016
OBTAIN IRRIGATION PERMIT
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
OBTAIN IRRIGATION PERMIT
Documents & Images
Date Uploaded File Type Document Name
10/30/2015 Letter Codes Building Permit
10/30/2015 Receipt Receipt for transaction: 2015-005984
11/02/2015 Plot Plan DOC110215-008
11/20/2015 Letter Inspection Summary
12/02/2015 Letter Inspection Summary
12/22/2015 Letter Inspection Summary
01/06/2016 Letter Inspection Summary
04/27/2016 Letter Inspection Summary
05/04/2016 Letter Inspection Summary
05/13/2016 Letter Inspection Summary
05/19/2016 Letter Inspection Summary
10/25/2016 Letter Inspection Summary
10/26/2016 Letter Codes Temporary Certificate of Occupancy
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home