JOHNSTON RE HOLDINGS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED PATIO - FINISHED BASEMENT
10/16/2015
10/21/2015
04/13/2016
07/08/2016
Locations
Contacts
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
JOHNSTON RE HOLDINGS LLC, Address:801 NE DEL LAGO CT  
WEST BRIAN & LESA, Address:3337 SW JESSIE CIR  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/22/2015 10/21/2015
James Fletchall
Residential Plan Review Approved 10/23/2015 10/21/2015
Tara Mitchell
Plot Plan Review Rejected 10/20/2015 10/20/2015
James Fletchall
Plot Plan Review (P&D) Approved 10/20/2015 10/16/2015
Christina Stanton
Residential Plan Review Rejected 10/20/2015 10/16/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $808.98 $808.98 Paid 10/21/2015
Right of Way Permit Fee $75.00 $75.00 Paid 10/21/2015
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/21/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 10/21/2015
Water Meter Fee $377.18 $377.18 Paid 10/21/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/21/2015 (2:45) 10/21/2015 at 12:00 AM 10/21/2015
Underslab Plumbing Inspection - Residential Passed 11/9/2015 at 12:00 AM 11/09/2015
All Rough Inspection - Residential Not Ready 2/8/2016 02/08/2016
Misc
Corrective Action Required
02/08/2016
INSPECTION DENIED DUE TO LACK OF EROSION CONTROL AND DEBRIS IN THE STREET.
All Rough Inspection - Residential Not Ready 2/10/2016 2/10/2016 02/10/2016
Misc
Corrective Action Required
02/08/2016
-PLEASE HAVE APPROVED PLAN ON SITE INSPECTION NOT COMPLETED WITHOUT APPROVED PLAN. BE ADVISED, ENGINEER WILL NEED TO ADDRESS ABSENSE OF BRACED WALL AT THE REAR DINING AREA. PLEASE CALL TO DISCUSS
All Rough Inspection - Residential Failed 2/11/2016 02/11/2016
Misc
Corrective Action Required
02/10/2016
-INSTALL STRAPS AT GARAGE PORTAL PER PLAN AND NAIL SHEATHING 3" O.C. -INSTALL ANCHOR BOLTS IN GARAGE WITHIN 12" OF PLATE BREAKS. -REAR WALL BREAKFAST, REQUIRED TO HAVE A BRACED WALL PANEL MIN. 27 INCHES WIDE WITHIN 10 FEET OF THE CORNER, HAVE AN ENGINEER ADDRESS. -INSTALL HANGER FOR LVL OVER LIVING ROOM -HOOK BATH FAN VENTS -ANCHOR POSTS IN BASEMENT
Gas Piping Inspection - Residential Passed 02/11/2016
Gas Service Inspection - Residential Passed 02/11/2016
Electrical Service Inspection Passed 02/11/2016
All Rough Inspection - Residential Not Ready 2/16/2016 2/16/2016 02/16/2016
Misc
Corrective Action Required
02/11/2016
-INSTALL ANCHOR BOLTS IN GARAGE WITHIN 12" OF PLATE BREAKS. -REAR WALL BREAKFAST, REQUIRED TO HAVE A BRACED WALL PANEL MIN. 27 INCHES WIDE WITHIN 10 FEET OF THE CORNER, HAVE AN ENGINEER ADDRESS. -INSTALL HANGER FOR LVL OVER LIVING ROOM -HOOK BATH FAN VENTS -ANCHOR POSTS IN BASEMENT FRAMER STILL WORKING
Sewer Service Inspection - R Passed 2/18/2016 (9:30) 2/18/2016 02/18/2016
All Rough Inspection - Residential Failed 02/18/2016
Misc
Corrective Action Required
02/16/2016
-ANCHOR POSTS IN BASEMENT OKAY TO INSULATE
Water Service Inspection - R Passed 2/19/2016 2/19/2016 02/19/2016
All Rough Inspection - Residential Passed 2/19/2016 2/19/2016 02/19/2016
Misc
Resolved
02/19/2016
-ANCHOR POSTS IN BASEMENT OKAY TO INSULATE
Suspended Slab Inspection Passed 4/20/2016 (1:15) 4/20/2016 04/20/2016
Piers/Caissons Inspection - Residential Passed 4/22/2016 4/22/2016 04/22/2016
Driveway Inspection Partial 4/22/2016 04/22/2016
PW-Misc
Corrective Action Required
04/22/2016
There are not any curb cuts or survey stakes to measure from to be sure that the driveway approach is formed at least 1' from the property line. I informed Bill Kenney of this and he will look into it and call for a re-inspection.
Driveway Inspection Failed 4/29/2016 04/29/2016
PW-Misc
Corrective Action Required
04/22/2016
There are not any curb cuts or survey stakes to measure from to be sure that the driveway approach is formed at least 1' from the property line. I informed Bill Kenney of this and he will look into it and call for a re-inspection.
PW-Misc
Resolved
04/29/2016
Brice Lawson 04/29/2016 9:47 AM Brice Lawson 04/29/2016 9:34 AM Bill Kenney had the property line marked with a curb-cut approx. 12" to the east of the driveway and approx. 15" to the west of the driveway.
PW-Sidewalk does not meet ADA requirements
Corrective Action Required
04/29/2016
The sidewalk does not meet ADA guidelines. Brice Lawson 04/29/2016 9:47 A.M. The cross slope of the sidewalk through the driveway is over 2%. When checked with a level, the level reads 2.7%, 2.8%, 2.9%, etc. This does not meet the cross slope requirements and needs to be replaced.
Driveway Inspection Partial 5/6/2016 05/10/2016
PW-Misc
Corrective Action Required
04/29/2016
There are not any curb cuts or survey stakes to measure from to be sure that the driveway approach is formed at least 1' from the property line. I informed Bill Kenney of this and he will look into it and call for a re-inspection.
PW-Sidewalk does not meet ADA requirements
Corrective Action Required
04/29/2016
The sidewalk does not meet ADA guidelines. Brice Lawson 04/29/2016 9:47 A.M. The cross slope of the sidewalk through the driveway is over 2%. When checked with a level, the level reads 2.7%, 2.8%, 2.9%, etc. This does not meet the cross slope requirements and needs to be replaced.
Driveway Inspection Passed 5/10/2016 05/10/2016
PW-Misc
Resolved
01/17/2017
There are not any curb cuts or survey stakes to measure from to be sure that the driveway approach is formed at least 1' from the property line. I informed Bill Kenney of this and he will look into it and call for a re-inspection.
PW-Misc
Informational
04/29/2016
Brice Lawson 04/29/2016 9:34 AM Bill Kenney had the property line marked with a curb-cut approx. 12" to the east of the driveway and approx. 15" to the west of the driveway.
PW-Sidewalk does not meet ADA requirements
Resolved
05/10/2016
The sidewalk does not meet ADA guidelines. Brice Lawson 04/29/2016 9:38 AM The cross slope of the sidewalk through the driveway is over two percent. When ckecked with a level, the level had readings of 2.7%, 2.8%, 2.9%,etc. Brice Lawson 05/10/2016 1:26 PM The contractor used the same level on several driveways in this area and those driveways passed the inspectons.
Occupancy Inspection - Codes Residential Not Ready 5/20/2016 5/20/2016 05/20/2016
Misc
Corrective Action Required
05/20/2016
DENIED FOR LACK OF EROSION CONTROL AND MUD IN THE STREEET.
Occupancy Inspection - Codes Residential Failed 5/23/2016 5/23/2016 05/23/2016
Misc
Corrective Action Required
05/20/2016
-OPEN GROUND GARAGE EAST WALL RECEPTACLE -FIRE CAULK HOSE BIBB IN GARAGE -INSTALL SELF CLOSING DEVICE GARAGE DOOR TO HOUSE -INCOMPLETE DECK GAURDS AND STAIRS -LABEL ELECTRIC PANEL -TWO RECEPTACLES IN UNFINISHED BASEMENT AND 3 IN GARAGE NOT GFCI PROTECTED -TWO OPEN BOXES UNFINISHED BASEMENT CEILING -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS -RESTORE VEGETATION IN DISTURBED AREAS ON ADJOINING LOTS
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2016 5/26/2016 05/26/2016
Misc
Corrective Action Required
05/23/2016
-DECK STAIRS: INSTALL HANDRAIL, FLAT 2x6 TOO BIG, POUR DECK LANDING AT BOTTOM OF STAIRS, BLOCK RISORS ON STAIRS TO NOT ALLOW PASSAGE OF A 4" SPHERE. -TWO OPEN BOXES UNFINISHED BASEMENT CEILING -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS -RESTORE VEGETATION IN DISTURBED AREAS ON ADJOINING LOTS
Occupancy Inspection - Codes Residential Failed 7/1/2016 7/1/2016 07/01/2016
Misc
Corrective Action Required
05/26/2016
-DECK STAIRS: INSTALL HANDRAIL, FLAT 2x6 TOO BIG, POUR DECK LANDING AT BOTTOM OF STAIRS, BLOCK RISORS ON STAIRS TO NOT ALLOW PASSAGE OF A 4" SPHERE. -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS -RESTORE VEGETATION IN DISTURBED AREAS ON ADJOINING LOTS
Occupancy Inspection - Codes Residential Full C of O 07/08/2016
Misc
Resolved
07/08/2016
-DECK STAIRS: INSTALL HANDRAIL, FLAT 2x6 TOO BIG, POUR DECK LANDING AT BOTTOM OF STAIRS, BLOCK RISORS ON STAIRS TO NOT ALLOW PASSAGE OF A 4" SPHERE. -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS -RESTORE VEGETATION IN DISTURBED AREAS ON ADJOINING LOTS
Documents & Images
Date Uploaded File Type Document Name
10/21/2015 Letter Codes Building Permit
10/21/2015 Receipt Receipt for transaction: 2015-005864
10/21/2015 Letter Codes Building Permit
10/21/2015 Letter Codes Building Permit
10/21/2015 Letter Inspection Summary
10/21/2015 Plot Plan DOC102115-002
11/09/2015 Letter Inspection Summary
02/08/2016 Letter Inspection Summary
02/10/2016 Letter Inspection Summary
02/11/2016 Letter Inspection Summary
02/16/2016 Letter Inspection Summary
02/18/2016 Letter Inspection Summary
02/19/2016 Engineer Report/Study DOC021916
02/19/2016 Letter Inspection Summary
04/20/2016 Letter Inspection Summary
04/22/2016 Letter Inspection Summary
04/22/2016 Letter PW-Daily Inspection Summary
04/29/2016 Letter PW-Daily Inspection Summary
05/20/2016 Letter Inspection Summary
05/23/2016 Letter Inspection Summary
05/26/2016 Letter Codes Temporary Certificate of Occupancy
07/01/2016 Letter Inspection Summary
07/08/2016 Letter Field Certificate of Occupancy
07/11/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home