Summary
PRRES20151618
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME WITH COVERED DECK
07/20/2015
07/23/2015
01/17/2016
01/29/2016
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/27/2015 07/23/2015
James Fletchall
Residential Plan Review Approved 07/27/2015 07/23/2015
Tara Mitchell
Plot Plan Review Rejected 07/22/2015 07/23/2015
James Fletchall
Plot Plan Review (P&D) Approved 07/22/2015 07/22/2015
Ron Seyl
Residential Plan Review Rejected 07/22/2015 07/21/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,401.95 $1,401.95 Paid 07/23/2015
Right of Way Permit Fee $75.00 $75.00 Paid 07/23/2015
8331507-Sewer Connection Fee $690.00 $690.00 Paid 07/23/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 07/23/2015
Water Meter Fee $377.18 $377.18 Paid 07/23/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/29/2015 (11:30) 7/29/2015 at 12:00 AM 07/29/2015
Footing Inspection - Residential Failed 08/03/2015
Misc
Corrective Action Required
08/03/2015
REBAR DOES NOT HAVE THE REQUIRED OVERLAP AT CORNERS. DO NOT POUR WITHOUT APPROVAL
Foundation Inspection - Residential Passed 08/03/2015
Misc
Resolved
08/03/2015
REBAR DOES NOT HAVE THE REQUIRED OVERLAP AT CORNERS. DO NOT POUR WITHOUT APPROVAL
Sewer Service Inspection - R Passed 8/13/2015 (10:45) 8/13/2015 at 12:00 AM 08/13/2015
Water Service Inspection - R Partial 8/17/2015 at 12:00 AM 08/13/2015
Water Service Inspection - R Passed 8/17/2015 (10:00) 8/17/2015 at 12:00 AM 08/17/2015
Underslab Plumbing Inspection - Residential Passed 8/17/2015 at 12:00 AM 08/17/2015
All Rough Inspection - Residential Failed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
Misc
Corrective Action Required
10/07/2015
-CORNER STUDS AT GARAGE PORTAL HAVE BEEN NOTCHED AT THE BASE FOR ANCHOR BOLTS. INSTALL ADDITIONAL STUDS. -FIREBLOCKING USED AT GARAGE FUR DOWN IS NOT 3/4". INSTALL ADDITIONAL FIREBLOCKING. -COMPLETE DRAFTSTOPPING FOR OPEN WEB FLOOR TRUSSES BY SEALING AROUND BY SEALING AROUND PENETRATIONS. -INSTALL SECURITY BLOCK REAR DOOR. -INSTALL INSULATION SHIELD AROUND B VENT AT FIRST FLOOR MECH CHASE. -SEAL LOW VOLTAGE PENETRATIONS BETWEEN FLOORS. -SECURE FIREPLACES TO FRAMES AND SET GAS LINE FOR SECOND FLOOR. -FLASH PLUMBING VENTS. -MASTER CLOSET AND LAUNDRY LIGHTING CONDUCTORS WITHIN 6 FEET OF ATTIC ACCESS REQUIRE RUNNING BOARDS. -PROTECT CONDUCTORS ABOVE MAIN PANEL. -FRONT PORCH FRAMING, DOUGLAS FIR IN CONTACT WITH CONCRETE. -BUILDING CLEANOUT LOCATED UNDER BASEMENT STAIR LANDING AND IS NOT ACCESSIBLE. OKAY TO INSULATE
Corrective Action Required
10/07/2015
Gas Service Inspection - Residential Failed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
G2417 INSPECTION, TESTING AND PURGING
Corrective Action Required
10/07/2015
NO TEST PRESSURE, 2ND FLOOR FIREPLACE NOT INSTALLED
Electrical Service Inspection Passed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
All Rough Inspection - Residential Failed 10/14/2015 (8:00 to 5:00) 10/14/2015 at 12:00 AM 10/14/2015
Misc
Corrective Action Required
10/07/2015
-COMPLETE DRAFTSTOPPING FOR OPEN WEB FLOOR TRUSSES BY SEALING AROUND BY SEALING AROUND PENETRATIONS. -INSTALL SECURITY BLOCK REAR DOOR. -SECURE FIREPLACES TO FRAMES OKAY TO INSULATE
Gas Service Inspection - Residential Passed 10/14/2015 at 12:00 AM 10/14/2015
G2417 INSPECTION, TESTING AND PURGING
Resolved
10/14/2015
NO TEST PRESSURE, 2ND FLOOR FIREPLACE NOT INSTALLED
All Rough Inspection - Residential Passed 10/15/2015 10/15/2015 at 12:00 AM 10/15/2015
Misc
Resolved
10/15/2015
-COMPLETE DRAFTSTOPPING FOR OPEN WEB FLOOR TRUSSES BY SEALING AROUND BY SEALING AROUND PENETRATIONS. -INSTALL SECURITY BLOCK REAR DOOR. -SECURE FIREPLACES TO FRAMES OKAY TO INSULATE
Driveway Inspection Passed 11/12/2015 at 12:00 AM 11/13/2015
Suspended Slab Inspection Passed 11/13/2015 (2:00) 11/13/2015 at 12:00 AM 11/13/2015
Occupancy Inspection - Codes Residential Not Ready 12/14/2015 12/14/2015 12/14/2015
Misc
Corrective Action Required
12/14/2015
THIS HOUSE ISN'T READY FOR FINAL INSPECTION. TOO MANY VIOLATIONS FOR INSPECTION
Occupancy Inspection - Codes Residential Not Ready 12/15/2015 12/15/2015
Misc
Corrective Action Required
12/14/2015
*****NOT A COMPLETE INSPECTION********** INSTALL SIDEWALK OR ESCROW PROVIDE GARAGE SEPARATION INSTALL SPRINKLER HEAD IN MECH ROOM OR INSTALL1/2 INCH GYP COMPLETE DECK
Occupancy Inspection - Codes Residential Temporary C of O 12/18/2015 12/18/2015
Misc
Corrective Action Required
12/15/2015
-SOUTH MASTER BATH WINDOW IS REQUIRED TO BE TEMPERED SAFETY GLASS -INSTALL SOD SPLASHBLOCKS
Occupancy Inspection - Codes Residential Temporary C of O 12/18/2015
Misc
Corrective Action Required
12/18/2015
-SOUTH MASTER BATH WINDOW IS REQUIRED TO BE TEMPERED SAFETY GLASS -INSTALL SOD SPLASHBLOCKS
Occupancy Inspection - Codes Residential Full C of O 01/29/2016
Misc
Resolved
01/29/2016
-SOUTH MASTER BATH WINDOW IS REQUIRED TO BE TEMPERED SAFETY GLASS -INSTALL SOD SPLASHBLOCKS
Sidewalk Inspection Passed 12/11/2015 at 12:00 AM 02/17/2016
PW-Sidewalk does not meet ADA requirements
Corrective Action Required
12/11/2015
The sidewalk does not meet ADA guidelines. Cross slope is over 2%. Left voicemail with Pat Cochran.
Sidewalk Inspection Passed 02/17/2016
PW-Sidewalk does not meet ADA requirements
Corrective Action Required
12/11/2015
The sidewalk does not meet ADA guidelines. Cross slope is over 2%. Left voicemail with Pat Cochran.
Sidewalk Inspection Passed 12/17/2015 02/17/2016
Documents & Images
Date Uploaded File Type Document Name
07/23/2015 Letter Codes Building Permit
07/23/2015 Receipt Receipt for transaction: 2015-004329
07/27/2015 Plot Plan DOC072715-009
07/29/2015 Letter Inspection Summary
08/03/2015 Letter Inspection Summary
08/03/2015 Letter Inspection Summary
08/03/2015 Letter Inspection Summary
08/13/2015 Letter Inspection Summary
08/17/2015 Letter Inspection Summary
10/07/2015 Letter Inspection Summary
10/14/2015 Letter Inspection Summary
10/15/2015 Letter Inspection Summary
11/13/2015 Letter Inspection Summary
12/11/2015 Letter PW-Daily Inspection Summary
12/14/2015 Letter Inspection Summary
12/15/2015 Letter Inspection Summary
12/18/2015 Letter Codes Temporary Certificate of Occupancy
12/18/2015 Letter Codes Temporary Certificate of Occupancy
01/29/2016 Letter Field Certificate of Occupancy
02/19/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home