Permit Application Status

PRRES20151238


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20151238
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE W/ COVERED PATIO - 2 STORY - FINISHED BASEMENT *ROOF TRUSSES
06/02/2015
06/15/2015
11/29/2015
03/22/2018
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 06/11/2015 06/12/2015
Ron Seyl
Plot Plan Review Approved 06/15/2015 06/12/2015
James Fletchall
Plot Plan Review Rejected 06/04/2015 06/11/2015
James Fletchall
Plot Plan Review (P&D) Rejected 06/04/2015 06/09/2015
Ron Seyl
Residential Plan Review Approved 06/09/2015 06/05/2015
Tara Mitchell
Residential Plan Review Rejected 06/04/2015 06/02/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,317.20 $1,317.20 Paid 06/15/2015
Right of Way Permit Fee $75.00 $75.00 Paid 06/15/2015
8331507-Sewer Connection Fee $690.00 $690.00 Paid 06/15/2015
Water Tap Fee $3,198.00 $3,198.00 Paid 06/15/2015
Water Meter Fee $354.05 $354.05 Paid 06/15/2015
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 09/24/2015
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 09/25/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/25/2015 (8:30) 6/25/2015 at 12:00 AM 06/25/2015
Sewer Service Inspection - R Passed 7/16/2015 at 12:00 AM 07/16/2015
Underslab Plumbing Inspection - Residential Passed 7/16/2015 7/16/2015 at 12:00 AM 07/16/2015
Water Service Inspection - R Partial 7/17/2015 (10:45) 7/17/2015 at 12:00 AM 07/16/2015
Water Service Inspection - R Passed 7/17/2015 (10:45) 7/17/2015 at 12:00 AM 07/17/2015
All Rough Inspection - Residential Not Ready 9/8/2015 9/8/2015 at 12:00 AM 09/08/2015
Misc
Corrective Action Required
09/08/2015
REQUESTED INSPECTION DENIED FOR THE FOLLOWING REASONS: 1. SUB-CONTRACTORS LISTED ON THE PERMIT ARE NOT CORRECT. 2. NO PLANS ON SITE FOR INSPECTION. 3. DEFICIANT EROSION CONTROL IN THE FRONT AND MUD IN THE STREET.
All Rough Inspection - Residential Failed 9/9/2015 at 12:00 AM 09/09/2015
Misc
Resolved
09/09/2015
REQUESTED INSPECTION DENIED FOR THE FOLLOWING REASONS: 1. SUB-CONTRACTORS LISTED ON THE PERMIT ARE NOT CORRECT. 2. NO PLANS ON SITE FOR INSPECTION. 3. DEFICIANT EROSION CONTROL IN THE FRONT AND MUD IN THE STREET.
Misc
Corrective Action Required
09/09/2015
-FIREBLOCK FIRESTOP FUR OUTS, TUB TRAPS -BEARING STUDS DRILLED MORE 40% REQUIRE STUD SHOES -TOP PLATES DRILL MORE THAN 50% REQUIRE STRAPS WITH 4 NAILS EACH SIDE -NOTCH IN THE MIDDLE THIRD OF JOIST SPAN 1st FLOOR NW BED -GARAGE, INSTALL PLATE BOLTS PER PORTAL DETAIL AND WITHIN 12" OF END OF A PLATE SECTION -INSTALL 1000 lb. STRAPS GARAGE PORTAL PER DETAIL -PROTECT 10 GUAGE CONDUCTOR WEST WALL GARAGE AT I BEAM STUD SUPPORT -REAR WALL DINING ROOM, NOT BUILT PER DETAIL, HEADER NOT EXTENDED TO CORNERS, straps ETC. HAVE ENGINEER ADDRESS -HAVE ENGINEER ADDRESS CORNER STUD FRAMING AT FOYER. STUDS CUT FOR FRONT PORCH HEADER, NOT ENOUGH CORNER STUD CONNECTION -VENT BASEMENT WET BAR DO NOT INSULATE
Corrective Action Required
09/09/2015
Gas Piping Inspection - Residential Passed 09/09/2015
Gas Service Inspection - Residential Passed 09/09/2015
Electrical Service Inspection Passed 09/09/2015
Misc
Corrective Action Required
09/09/2015
GROUNDING CONDUCTOR NOT CONNECTED TO UFFER GROUND
All Rough Inspection - Residential Failed 9/14/2015 9/14/2015 at 12:00 AM 09/14/2015
Misc
Corrective Action Required
09/09/2015
-FIREBLOCK FIRESTOP FUR OUTS, TUB TRAPS OKAY INSULATE
All Rough Inspection - Residential Failed 9/23/2015 9/23/2015 at 12:00 AM 09/23/2015
Misc
Corrective Action Required
09/14/2015
-FIREBLOCK FIRESTOP FUR OUTS, TUB TRAPS FUR OUTS 1ST FLOOR STILL HAVE NO FIRESTOPPING. CAN NOT SEE TUB TRAPS DUE TO THE GYP ON THE LID RE-INSPECTION FEE
All Rough Inspection - Residential Failed 9/25/2015 9/25/2015 at 12:00 AM 09/25/2015
Misc
Corrective Action Required
09/23/2015
-FIREBLOCK FIRESTOP FUR OUTS, TUB TRAPS FUR OUTS 1ST FLOOR STILL HAVE NO FIRESTOPPING. CAN NOT SEE TUB TRAPS DUE TO THE GYP ON THE LID ****25-SEPT-RE-INSPECTION FEE ASSESSED FOR NO ACCESS. PLEASE LEAVE THE ACCESS CODE SO AN INSPECTOR CAN INSPECT
All Rough Inspection - Residential Passed 9/28/2015 at 12:00 AM 09/28/2015
Misc
Resolved
09/28/2015
-FIREBLOCK FIRESTOP FUR OUTS, TUB TRAPS FUR OUTS 1ST FLOOR STILL HAVE NO FIRESTOPPING. CAN NOT SEE TUB TRAPS DUE TO THE GYP ON THE LID ****25-SEPT-RE-INSPECTION FEE ASSESSED FOR NO ACCESS. PLEASE LEAVE THE ACCESS CODE SO AN INSPECTOR CAN INSPECT
Driveway Inspection Passed 10/2/2015 at 12:00 AM 10/12/2015
Occupancy Inspection - Codes Residential Failed 12/17/2015 12/17/2015 12/17/2015
Misc
Corrective Action Required
12/17/2015
-REMOVE ACCESS PANEL UNDER BASEMENT STAIRS, MAKE SURE THAT UNDER STAIRS AND WALLS ARE PROTECTED WITH 1/2 ROCK -INSTALL SECURITY SCREWS REAR DOOR. GARAGE WILL NEED INSPECTED AFTER IT IS RE ESTABLISHED.
Occupancy Inspection - Codes Residential Failed 2/17/2016 2/17/2016 02/17/2016
Misc
Corrective Action Required
12/17/2015
-NO RECORD OF SIDEWALK INSPECTION FROM PUBLIC WORKS. -INSTALL SECURITY SCREWS REAR DOOR. GARAGE WILL NEED INSPECTED AFTER IT IS RE ESTABLISHED.
Investigation Inspection Complete 8/15/2016 08/15/2016
Investigation Inspection Complete 2/11/2017 03/21/2018
Plot Plan Inspection Passed 3/22/2018 3/22/2018 03/22/2018
Occupancy Inspection - Codes Residential Full C of O 3/22/2018 3/22/2018 03/22/2018
Misc
Resolved
03/22/2018
- - GARAGE WILL NEED INSPECTED AFTER IT IS RE ESTABLISHED.
Documents & Images
Date Uploaded File Type Document Name
06/15/2015 Receipt Receipt for transaction: 2015-002878
06/15/2015 Letter Codes Building Permit
06/15/2015 Plot Plan DOC061515-009
06/25/2015 Letter Inspection Summary
07/16/2015 Letter Inspection Summary
07/17/2015 Letter Inspection Summary
09/08/2015 Letter Inspection Summary
09/09/2015 Letter Inspection Summary
09/14/2015 Engineer Report/Study 265 SW Coyle Dr Lot 108 Mill Creek
09/14/2015 Letter Inspection Summary
09/23/2015 Letter Inspection Summary
09/23/2015 Letter Re-Inspection Fee
09/24/2015 Receipt Receipt for transaction: 2015-005507
09/25/2015 Letter Re-Inspection Fee
09/25/2015 Letter Inspection Summary
09/25/2015 Receipt Receipt for transaction: 2015-005521
09/28/2015 Letter Inspection Summary
12/17/2015 Letter Inspection Summary
02/17/2016 Letter Inspection Summary
03/22/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home