Permit Application Status

PRRES20150974


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20150974
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE - UNFINISHED BASEMENT
05/07/2015
05/15/2015
11/04/2015
02/12/2016
Locations
Contacts
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 05/12/2015 05/15/2015
Tara Mitchell
Residential Plan Review Approved 05/19/2015 05/15/2015
Tara Mitchell
Plot Plan Review Approved 05/14/2015 05/14/2015
James Fletchall
Plot Plan Review Rejected 05/12/2015
James Fletchall
Plot Plan Review (P&D) Rejected 05/08/2015
Ron Seyl
Residential Plan Review Rejected 05/11/2015 05/08/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $614.90 $614.90 Paid 05/15/2015
Right of Way Permit Fee $75.00 $75.00 Paid 05/15/2015
8331507-Sewer Connection Fee $360.00 $360.00 Paid 05/15/2015
Water Tap Fee $3,198.00 $3,198.00 Paid 05/15/2015
Water Meter Fee $354.05 $354.05 Paid 05/15/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/21/2015 (3:30) 5/21/2015 at 12:00 AM 05/21/2015
Underslab Plumbing Inspection - Residential Passed 7/1/2015 7/1/2015 at 12:00 AM 06/30/2015
Sewer Service Inspection - R Passed 8/19/2015 (1:30) 8/19/2015 at 12:00 AM 08/19/2015
Water Service Inspection - R Passed 8/20/2015 (10:30) 8/20/2015 at 12:00 AM 08/20/2015
All Rough Inspection - Residential Not Ready 9/9/2015 9/9/2015 at 12:00 AM 09/09/2015
Misc
Corrective Action Required
09/09/2015
NEED APPROVED PLANS ON SITE FOR INSPECTION
All Rough Inspection - Residential Failed 9/11/2015 9/11/2015 at 12:00 AM 09/11/2015
Misc
Corrective Action Required
09/09/2015
-install 1000 lb. straps at garage portal per plan detail -nail exterior corner studs 12" o.c minimum -install 4 studs at point load for LVL in basement and 1st floor -walls taller than 10' must have studs from floor to ceiling without breaks Do not insulate
Gas Piping Inspection - Residential Passed 09/11/2015
Electrical Service Inspection Passed 09/11/2015
Gas Service Inspection - Residential Passed 09/11/2015
All Rough Inspection - Residential Passed 9/18/2015 9/18/2015 at 12:00 AM 09/18/2015
Misc
Resolved
09/18/2015
-install 1000 lb. straps at garage portal per plan detail -nail exterior corner studs 12" o.c minimum -install 4 studs at point load for LVL in basement and 1st floor -walls taller than 10' must have studs from floor to ceiling without breaks Do not insulate
Partial Correction
09/18/2015
APPROVED TO COVER PENDING ENGINEER REPORT
Driveway Inspection Passed 11/25/2015 at 10:50 AM 12/14/2015
Occupancy Inspection - Codes Residential Failed 1/26/2016 1/26/2016 01/26/2016
Misc
Corrective Action Required
01/26/2016
- PROVIDE SIDEWALK APPROVAL FROM PW -COMPLETE SOD AND GRADE - GUTTERS SPLASHBLOCKS DOWN SPOUTS -MISSING SPINDLES MAIN STAIRS - 1ST FLOOR TO LANDING, HAND/GUARD RAIL IS TOO LOW AT 32", MIN IS 34" FROM NOSING TO HANDRAIL -SECURE EGRESS LADDER - CUT DRAIN TILE IN WINDOW WELL - CUT OFF CLEAN OUT FRONT YARD FLUSH WITH GRADE - OBTAIN LAWN SPRINKLER PERMIT -CLEAN STREETS - REAR STEPS AT REAR DOOR ARE BUILT INCORRECTLY, RISE RUN AND UNTREATED LUMBER.
Sidewalk Inspection Passed 01/28/2016
Occupancy Inspection - Codes Residential Failed 1/29/2016 1/29/2016 01/29/2016
Misc
Corrective Action Required
01/26/2016
-INSTALL SPLASHBLOCKS 36 INCHES FROM FOUNDATION -MISSING SPINDLES MAIN STAIRS - OBTAIN LAWN SPRINKLER PERMIT
Occupancy Inspection - Codes Residential Temporary C of O 01/29/2016
Misc
Corrective Action Required
01/29/2016
-INSTALL SPLASHBLOCKS 36 INCHES FROM FOUNDATION - OBTAIN LAWN SPRINKLER PERMIT
Occupancy Inspection - Codes Residential Full C of O 02/12/2016
Misc
Resolved
02/12/2016
-INSTALL SPLASHBLOCKS 36 INCHES FROM FOUNDATION - OBTAIN LAWN SPRINKLER PERMIT
Documents & Images
Date Uploaded File Type Document Name
05/15/2015 Receipt Receipt for transaction: 2015-001321
05/15/2015 Letter Codes Building Permit
05/15/2015 Plot Plan DOC051515-007
06/30/2015 Letter Inspection Summary
08/19/2015 Letter Inspection Summary
08/20/2015 Letter Inspection Summary
09/09/2015 Letter Inspection Summary
09/11/2015 Letter Inspection Summary
09/18/2015 Letter Inspection Summary
01/15/2016 Engineer Report/Study 3345
01/26/2016 Letter Inspection Summary
01/29/2016 Letter Inspection Summary
01/29/2016 Letter Codes Temporary Certificate of Occupancy
02/12/2016 Letter Field Certificate of Occupancy
02/16/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: