Permit Application Status

PRRES20143054


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20143054
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - FINISHED WALKOUT *SEPTIC SYSTEM
10/29/2014
11/18/2014
04/27/2015
02/22/2016
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/20/2014 11/18/2014
Development Center
Plot Plan Review (P&D) Approved 10/31/2014 11/04/2014
Hector Soto Jr.
Plot Plan Review Approved 11/04/2014
Gene Williams, P.E.
Plot Plan Review Rejected 10/31/2014 10/31/2014
Gene Williams, P.E.
Misc
Corrective Action Required
10/31/2014

1. The right of way dimension must be provided. 2. The driveway portion from the edge of Pryor Rd. (i.e., the edge of pavement) to the right of way line must be constructed of 6” thick KCMMB mix concrete.
Residential Plan Review Rejected 10/31/2014 10/29/2014
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $958.92 $958.92 Paid 11/18/2014
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/18/2014
8331401-Water Tap Fee $3,198.00 $3,198.00 Paid 11/18/2014
8350015-Water Meter Fee $354.05 $354.05 Paid 11/18/2014
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/20/2014 (2:15) 11/20/2014 at 12:00 AM 11/20/2014
Underslab Plumbing Inspection - Residential Passed 12/2/2014 12/2/2014 at 12:00 AM 12/02/2014
Gas Service Inspection - Residential Failed 1/7/2015 1/7/2015 at 12:00 AM 01/07/2015
Misc
Corrective Action Required
01/07/2015
fireplace not installed - recall when firepalce and flue is set.
Gas Service Inspection - Residential Failed 1/20/2015 1/20/2015 at 12:00 AM 01/20/2015
Misc
Corrective Action Required
01/07/2015
fireplace not installed - recall when firepalce and flue is set. 2nd inspection- install gas lines to fireplaces pressure is ok
Electrical Service Inspection Failed 1/20/2015 1/20/2015 at 12:00 AM 01/20/2015
Misc
Corrective Action Required
01/20/2015
ground panels to water service
All Rough Inspection - Residential Failed 1/20/2015 1/20/2015 at 12:00 AM 01/20/2015
Misc
Corrective Action Required
01/20/2015
- firestop basement walls vertical to horizontal and every 10 horizontal, bath room, bedroom, all required locations - 1/2 plywood used as firestop 3/4" required - sub panel not isntalled in furance room? - solid block over i beams and bearing locations on all joist -strap garage door headers to top plates , braced wall requirement - plate bolts rear basement wall at door and garage door. - ground panel to water line - tempered window needed over stairs ok to insulate do not cover inspection items.
Water Service Inspection - R Partial 1/20/2015 (1:30) 1/20/2015 at 12:00 AM 01/20/2015
Water Service Inspection - R Passed 1/22/2015 (8:00) 1/22/2015 at 12:00 AM 01/22/2015
All Rough Inspection - Residential Passed 1/26/2015 1/26/2015 at 12:00 AM 01/26/2015
Misc
Resolved
01/26/2015
- firestop basement walls vertical to horizontal and every 10 horizontal, bath room, bedroom, all required locations - 1/2 plywood used as firestop 3/4" required - sub panel not isntalled in furance room? - solid block over i beams and bearing locations on all joist -strap garage door headers to top plates , braced wall requirement - plate bolts rear basement wall at door and garage door. - ground panel to water line ok to insulate do not cover inspection items.
Gas Service Inspection - Residential Passed 1/28/2015 1/28/2015 at 12:00 AM 01/28/2015
Misc
Resolved
01/28/2015
fireplace not installed - recall when firepalce and flue is set. 2nd inspection- install gas lines to fireplaces pressure is ok
Electrical Service Inspection Passed 1/28/2015 1/28/2015 at 12:00 AM 01/28/2015
Misc
Resolved
01/28/2015
ground panels to water service
Occupancy Inspection - Codes Residential Failed 6/2/2015 6/2/2015 at 12:00 AM 06/02/2015
Misc
Corrective Action Required
06/02/2015
- PROVIDE APPROVAL FROM JACKSON COUNTY ON SEPTIC SYSTEM - PROVIDE APPROVAL FROM PUBLIC WORKS ON DRIVE WAY APPROACH -LOCKOUTS ON HARD WIRED APPLIANCES -LABEL SMOKE DETECTOR BREAKER - FINAL GRADE, SEEDING, SOD EROSION CONTROL. - PROVIDE ADDRESS AT ROAD. -SEAL BOTTOM OF BOX OUT IN GARAGE WITH APROVED MATERIAL.
Occupancy Inspection - Codes Residential Temporary C of O 6/9/2015 6/9/2015 at 12:00 AM 06/09/2015
Misc
Corrective Action Required
06/02/2015
- PROVIDE APPROVAL FROM PUBLIC WORKS ON DRIVE WAY APPROACH - FINAL GRADE, SEEDING, SOD EROSION OK FOR TCO 60DAY
Driveway Inspection Partial 2/12/2016 at 8:33 AM 02/12/2016
PW-Misc
Informational
02/12/2016
Forms are set and subgrade is in place and compacted. Contractor cut a straight edge along asphalt where the drive meets the road to remove the loose asphalt.
Driveway Inspection Passed 2/17/2016 02/19/2016
PW-Misc
Informational
02/12/2016
Forms are set and subgrade is in place and compacted. Contractor cut a straight edge along asphalt where the drive meets the road to remove the loose asphalt.
PW-Misc
Informational
02/19/2016
The driveway approach has been installed and the forms have been removed.
Occupancy Inspection - Codes Residential Full C of O 02/22/2016
Misc
Resolved
02/22/2016
- PROVIDE APPROVAL FROM PUBLIC WORKS ON DRIVE WAY APPROACH - FINAL GRADE, SEEDING, SOD EROSION OK FOR TCO 60DAY
Documents & Images
Date Uploaded File Type Document Name
11/18/2014 Letter Codes Building Permit
11/18/2014 Receipt Receipt for transaction: 2014-002203
11/18/2014 Plot Plan DOC111814-001
11/20/2014 Letter Inspection Summary
12/02/2014 Letter Inspection Summary
01/07/2015 Letter Inspection Summary
01/20/2015 Letter Inspection Summary
01/20/2015 Letter Inspection Summary
01/20/2015 Letter Inspection Summary
01/22/2015 Letter Inspection Summary
01/26/2015 Letter Inspection Summary
01/28/2015 Letter Inspection Summary
06/02/2015 Letter Inspection Summary
06/09/2015 Letter Codes Temporary Certificate of Occupancy
06/12/2015 Letter DOC061215
02/12/2016 Letter PW-Daily Inspection Summary
02/22/2016 Letter Field Certificate of Occupancy
02/23/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home