Summary
PRRES20130943
Building Permit - Residential
Certificate of Occupancy
LENCIONI JAMES N & KAREN M TRUSTEE
NEW SINGLE FAMILY
HOUSE
05/17/2013
06/19/2013
11/12/2013
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
LENCIONI JAMES N & KAREN M TRUSTEE, Address:1101 SW WHISTLE DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/21/2013 06/06/2013
Codes Admin
Plot Plan Review (P&D) Approved 05/21/2013 06/04/2013
Jennifer Thompson
Plot Plan Review Approved 05/21/2013 05/23/2013
Gene Williams, P.E.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $900.38 $900.38 Paid 06/19/2013
$900.38
9110073-Right of Way Permit Fee $60.00 $60.00 Paid 06/19/2013
$60.00
8331401-Water Tap Fee $3,085.00 $3,085.00 Paid 06/19/2013
$3,085.00
8350015-Water Meter Fee $253.99 $253.99 Paid 06/19/2013
$253.99
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Passed 7/8/2013 (3:15) 7/8/2013 at 12:00 AM 07/08/2013
All Rough Inspection - Residential Failed 9/3/2013 9/3/2013 at 12:00 AM 09/03/2013
Misc
Corrective Action Required
09/03/2013
1. NAIL DBL TRUSS PER PLANS 2. INSTALL BRACED WALLS PER PLANS 3. INSTALL HURRICANE STRAPS 2ND FLOOR , FRON MSTR, ALL EXTERIO BEARING TRUSS 4. FIRESTOP MSTR TUB, INSTALL MSTR TUB, SOLID BLOCK REAR 2ST FLOOR CHASE BACK WALL. BUILD REAR N.E. CHASE GREAT ROOM, FIRESTOP LANDING FROM WALL, 5.ANCOR BSMT BEAM POST, ANCOR GARAGAE BEAM POST. 6. INSTALL GAS LINE 7. SUPPORT 2X10 AT STAIR WALL NEXT TO LVL 8. SUPPORT ALL LVL AND BEARING POINT WITH CORRECT NUMBER OF STUDS AS PER PLANS, BREAKFAST NOOK, DINNING ETC. 9. INSTALL DBL JOIST BSMT AS PER PLANS 10. FIRESTOP HEAT CHASE REAR CENTER BEDROOM CLOSET CHASE 11. SUPPORT DWV 48" OC.C, SUPPORT PEX PIPING IN WALL AT 36". 12.FLUE CLEARANCE TO PEX AND ROMEX. 13. GARAGE DOOR STRAPS 14. ROMEX 6' ATTICE ACCESS-PROTECT 15. JOIST HANGER NAILS 1ST FLOOR OVER BENCH HALL- DO NOT COVER
Electrical Service Inspection Passed 9/3/2013 at 12:00 AM 09/03/2013
All Rough Inspection - Residential Failed 9/6/2013 at 12:00 AM 09/06/2013
Misc
Corrective Action Required
09/03/2013
4. FIRESTOP MSTR TUB, SOLID BLOCK REAR 2ST FLOOR CHASE BACK WALL.FIRESTOP LANDING FROM WALL, 9. INSTALL DBL JOIST BSMT AS PER PLANS 13. GARAGE DOOR STRAPS 3rd CAR
All Rough Inspection - Residential Passed 9/10/2013 9/10/2013 at 12:00 AM 09/10/2013
Misc
Resolved
09/10/2013
4. FIRESTOP MSTR TUB, SOLID BLOCK REAR 2ST FLOOR CHASE BACK WALL.FIRESTOP LANDING FROM WALL, 9. INSTALL DBL JOIST BSMT AS PER PLANS 13. GARAGE DOOR STRAPS 3rd CAR DO NOT COVER
Gas Service Inspection - Residential Passed 9/12/2013 9/12/2013 at 12:00 AM 09/12/2013
Occupancy Inspection - Codes Residential Failed 11/6/2013 11/6/2013 at 12:00 AM 11/06/2013
Misc
Corrective Action Required
11/06/2013
1. EGRESS LADDER 2.ADJUST WATER HEATER FLUE FOR POSITIVE FALL 3. PROVIDE REPORT ON SEPTIC SYSTEM FROM THE COUNTY
Occupancy Inspection - Codes Residential Full C of O 11/12/2013 11/12/2013 at 12:00 AM 11/12/2013
Misc
Resolved
11/12/2013
3. PROVIDE REPORT ON SEPTIC SYSTEM FROM THE COUNTY
Plot Plan Inspection Passed 04/09/2014
Documents & Images
Date Uploaded File Type Document Name
06/19/2013 Plot Plan
06/19/2013 Letter Building Permit
07/08/2013 Letter Inspection Summary
09/03/2013 Letter Inspection Summary
09/06/2013 Letter Inspection Summary
09/10/2013 Letter Inspection Summary
09/12/2013 Letter Inspection Summary
09/26/2013 Letter DOC092613.pdf
11/06/2013 Letter Inspection Summary
11/12/2013 Letter Field Certificate of Occupancy
11/13/2013 Letter Codes Final Certificate of Occupancy
11/20/2013 Letter DOC112013-003.pdf
01/15/2014 Letter DOC011514-006.pdf
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home