Permit Application Status

PRRES20121444


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20121444
Building Permit - Residential
Certificate of Occupancy
ROBERT D REED
REPAIR REPLACE UPGRADE
MOVE METER CAN FROM POLE TO EXTERIOR OF HOUSE UPGRADE ELECTRICAL OUTLETS ON THE INTERIOR OF HOUSE
06/26/2012
06/26/2012
03/18/2013
Locations
Contacts
ROBERT D REED, Address:713 NW BLACK TWIG , Phone:(816) 305-1556  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/26/2012
Codes Admin
True
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Repair/Replace/Upgrade $30.00 $30.00 Paid 06/26/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 7/3/2012 (8:00 to 5:00) 7/3/2012 at 12:00 AM 07/03/2012
Misc
Corrective Action Required
07/03/2012
ANIT-OXIDIZING COMPOUND REQUIRED AT TERMINATIONS OF ALUMINUM CONDUCTORS
Misc
Corrective Action Required
07/03/2012
NEC 110 - 26 (a) (b); IRC 3305.1: DEDICATED WORKING/CLEAR SPACE AT ELECTRICAL EQUIPMENT MUST BE WIDTH OF EQPMT OR 30" BY 36" DEEP
Misc
Corrective Action Required
07/03/2012
NEC 250; IRC E3510.1. SERVICE ENCLOSURES & EQUIPMENT MUST BE BONDED
Electrical Service Inspection Passed 7/5/2012 at 12:00 AM 07/05/2012
Misc
Resolved
07/05/2012
ANIT-OXIDIZING COMPOUND REQUIRED AT TERMINATIONS OF ALUMINUM CONDUCTORS
Misc
Resolved
07/05/2012
NEC 110 - 26 (a) (b); IRC 3305.1: DEDICATED WORKING/CLEAR SPACE AT ELECTRICAL EQUIPMENT MUST BE WIDTH OF EQPMT OR 30" BY 36" DEEP
Misc
Resolved
07/05/2012
NEC 250; IRC E3510.1. SERVICE ENCLOSURES & EQUIPMENT MUST BE BONDED
All Rough Inspection - Residential Not Ready 7/10/2012 at 12:00 AM 07/10/2012
Misc
Corrective Action Required
07/10/2012
COURTESY WALK-THROUGH WITH P.H. IN ADVANCE OF ROUGH-IN INSPECTION
All Rough Inspection - Residential Failed 8/8/2012 8/8/2012 at 12:00 AM 08/08/2012
Misc
Corrective Action Required
07/10/2012
OK TO COVER FOLLOWING WALLS/CEILINGS: SHOWER WALLS ONLY AT BATHROOM
Misc
Corrective Action Required
08/08/2012
STRUCTURE AND OTHER SYSTEMS AT GARAGE AND CRAWL SPACE TO SUBJECT TO APPROVAL WHEN ACCESSIBLE AT OR BEFORE FINAL INSPECTION. NOTED THAT EXISTING OPEN ELECTRICAL SPLICES AT ATTIC HAVE BEEN ENCLOSED IN NEW JUNCTION BOXES.
Misc
Corrective Action Required
08/08/2012
ISOLATE NEUTRAL AND EQUIPMENT GROUND WIRE TERMINATIONS AT ELECTRICAL PANEL
Misc
Corrective Action Required
08/08/2012
SECURE NM ELECTRICAL CABLE TO STRUCTURE AT MAX 4.5' INTERVALS
Misc
Corrective Action Required
08/08/2012
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL
Misc
Corrective Action Required
08/08/2012
IRC R502.13; R602.8: FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN TOP & BOTTOM PLATES, HOLES IN FLOOR INCLUDING AT TUB, SHOWER, ETC
Misc
Corrective Action Required
08/08/2012
ALL SYSTEMS ROUGH-IN AT BATHROOM IN PROGRESS. SUBJECT TO APPROVAL WHEN COMPLETED. SHOWER WALLS OK TO COVER.
All Rough Inspection - Residential Partial 8/9/2012 8/9/2012 at 12:00 AM 08/09/2012
Misc
Partial Correction
08/09/2012
OK TO COVER WALLS & CEILINGS EXCEPT AT GARAGE
Misc
Corrective Action Required
08/08/2012
STRUCTURE AND OTHER SYSTEMS AT GARAGE AND CRAWL SPACE TO SUBJECT TO APPROVAL WHEN ACCESSIBLE AT OR BEFORE FINAL INSPECTION. NOTED THAT EXISTING OPEN ELECTRICAL SPLICES AT ATTIC HAVE BEEN ENCLOSED IN NEW JUNCTION BOXES.
Misc
Resolved
08/09/2012
ISOLATE NEUTRAL AND EQUIPMENT GROUND WIRE TERMINATIONS AT ELECTRICAL PANEL
Misc
Resolved
08/09/2012
SECURE NM ELECTRICAL CABLE TO STRUCTURE AT MAX 4.5' INTERVALS
Misc
Resolved
08/09/2012
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL
Misc
Resolved
08/09/2012
IRC R502.13; R602.8: FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN TOP & BOTTOM PLATES, HOLES IN FLOOR INCLUDING AT TUB, SHOWER, ETC
Misc
Resolved
08/09/2012
ALL SYSTEMS ROUGH-IN AT BATHROOM IN PROGRESS. SUBJECT TO APPROVAL WHEN COMPLETED. SRESHOWER WALLS OK TO COVER.
All Rough Inspection - Residential Partial 8/16/2012 at 12:00 AM 08/16/2012
Misc
Partial Correction
08/09/2012
OK TO COVER WALLS & CEILINGS EXCEPT AT GARAGE
Misc
Corrective Action Required
08/09/2012
STRUCTURE AND OTHER SYSTEMS AT GARAGE AND CRAWL SPACE TO SUBJECT TO APPROVAL WHEN ACCESSIBLE AT OR BEFORE FINAL INSPECTION. NOTED THAT EXISTING OPEN ELECTRICAL SPLICES AT ATTIC HAVE BEEN ENCLOSED IN NEW JUNCTION BOXES.
Misc
Corrective Action Required
08/16/2012
PARTIAL FINAL TO BE REQUESTED AFTER GWB IS HUNG SO ELECT RECEPTS CAN BE TESTED BEFORE PERMANENT USE
Occupancy Inspection - Codes Residential Failed 10/9/2012 at 12:00 AM 10/09/2012
Misc
Resolved
10/09/2012
ANIT-OXIDIZING COMPOUND REQUIRED AT TERMINATIONS OF ALUMINUM CONDUCTORS
Misc
Resolved
10/09/2012
NEC 110 - 26 (a) (b); IRC 3305.1: DEDICATED WORKING/CLEAR SPACE AT ELECTRICAL EQUIPMENT MUST BE WIDTH OF EQPMT OR 30" BY 36" DEEP
Misc
Resolved
10/09/2012
NEC 250; IRC E3510.1. SERVICE ENCLOSURES & EQUIPMENT MUST BE BONDED
Misc
Corrective Action Required
10/09/2012
COMPLETE INSTALLATION OF LIGHT FIXTURES & DEVICES
Misc
Corrective Action Required
10/09/2012
OPERABLE SMOKE ALARMS REQUIRED IN: - EACH BEDROOM - HALLWAY/ALCOVE ADJOINING BEDROOMS
Misc
Corrective Action Required
10/09/2012
NEC 210-52: ELECT RECEPTACLES AT KITCHEN COUNTERS MUST BE GFCI-PROTECTED
Misc
Corrective Action Required
10/09/2012
NEC 210-8; E3802.2: GFCI PROTECTION OF ELECTRICAL RECEPTACLES: DUPLEX ELECTRICAL RECEPTACLE AT CLOTHES WASHER NOT GFCI PROTECTED. IF NOT PROTECTED AND DESIGNATED AS "DEDICATED" FOR WASHER RECEPTACLE MUST BE SINGLE PLUG.
Misc
Corrective Action Required
10/09/2012
APPARENT HOT/GROUND REVERSE ON ELECT RECEPT AT LR W WALL @ S
Misc
Corrective Action Required
10/09/2012
APPARENT OPEN NEUTRAL ON ELECT RECEPT AT ALCOVE ADJOINING BEDROOMS
All Rough Inspection - Residential Passed 10/9/2012 at 12:00 AM 10/09/2012
Misc
Resolved
10/09/2012
OK TO COVER WALLS & CEILINGS EXCEPT AT GARAGE
Misc
Resolved
10/09/2012
STRUCTURE AND OTHER SYSTEMS AT GARAGE AND CRAWL SPACE TO SUBJECT TO APPROVAL WHEN ACCESSIBLE AT OR BEFORE FINAL INSPECTION. NOTED THAT EXISTING OPEN ELECTRICAL SPLICES AT ATTIC HAVE BEEN ENCLOSED IN NEW JUNCTION BOXES.
Misc
Resolved
10/09/2012
PARTIAL FINAL TO BE REQUESTED AFTER GWB IS HUNG SO ELECT RECEPTS CAN BE TESTED BEFORE PERMANENT USE
Occupancy Inspection - Codes Residential Full C of O 3/18/2013 at 12:00 AM 03/18/2013
Misc
Resolved
03/18/2013
COMPLETE INSTALLATION OF LIGHT FIXTURES & DEVICES
Misc
Resolved
03/18/2013
OPERABLE SMOKE ALARMS REQUIRED IN: - EACH BEDROOM - HALLWAY/ALCOVE ADJOINING BEDROOMS
Misc
Resolved
03/18/2013
NEC 210-52: ELECT RECEPTACLES AT KITCHEN COUNTERS MUST BE GFCI-PROTECTED
Misc
Resolved
03/18/2013
NEC 210-8; E3802.2: GFCI PROTECTION OF ELECTRICAL RECEPTACLES: DUPLEX ELECTRICAL RECEPTACLE AT CLOTHES WASHER NOT GFCI PROTECTED. IF NOT PROTECTED AND DESIGNATED AS "DEDICATED" FOR WASHER RECEPTACLE MUST BE SINGLE PLUG.
Misc
Resolved
03/18/2013
APPARENT HOT/GROUND REVERSE ON ELECT RECEPT AT LR W WALL @ S
Misc
Resolved
03/18/2013
APPARENT OPEN NEUTRAL ON ELECT RECEPT AT ALCOVE ADJOINING BEDROOMS
Documents & Images
Date Uploaded File Type Document Name
06/26/2012 Letter Building Permit
06/27/2012 Activity Document 20120627091447517.pdf
07/03/2012 Letter Inspection Summary
07/05/2012 Letter Inspection Summary
08/08/2012 Letter Inspection Summary
08/09/2012 Letter Inspection Summary
10/09/2012 Letter Inspection Summary
03/06/2013 Letter 140 Day Letter
03/18/2013 Letter Field Certificate of Occupancy
03/19/2013 Letter Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home