Permit Application Status

PRCOM20243058


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20243058
Building Permit - Commercial
Certificate of Occupancy
SOUTHPORT BUSINESS CENTER LLC
CHANGE OF TENANT
TENANT FINISH FOR MARKETING COMPANY
06/13/2024
07/10/2024
08/30/2024
Locations
Contacts
SOUTHPORT BUSINESS CENTER LLC, Address:1485 SW MARKET ST  
DEAN KIRBY, Address:DKIRBY@DLKIRBY.COM, Phone:(816) 365-0605  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
WESTCO ELECTRICAL SERVICES, Address:P O BOX 93, Phone:(816) 343-8779  
D.L. Kirby & Company, Address:517 SE 2ND ST STE A, Phone:(816) 365-0605  
The Hive Design Collaborative, Address:1617 Walnut St, Phone:(816) 581-6363  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/25/2024 07/03/2024
Joe Frogge
LC - MEP Subs
Resolved
07/03/2024

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. (LRW not currently licensed with us)
Building Plan Review Approved 06/25/2024 07/03/2024
Joe Frogge
IPC 403.1 Minimum number of fixtures
Resolved
07/03/2024

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide service/mop sink.
IBC 1209.2 Finish materials
Resolved
07/03/2024

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finish material at walls adjacent to water closet and mop sink. If paint is used it must be epoxy based.
Fire Plan Review Approved with Conditions 06/25/2024 07/03/2024
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
07/03/2024

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher in the space. Verified at inspection.
Miscellaneous Correction
Corrective Action Required
07/03/2024

The Code Review shows the building has a fire alarm system. If correct, provide pmodification plans for review and approval.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $360.00 $360.00 Paid 07/03/2024
$8,415.00
7232302-Commercial License Tax Fee $4,207.50 $4,207.50 Paid 06/13/2024
$4,207.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 7/16/2024 7/16/2024 07/16/2024
Above Ceiling Inspection Passed 8/26/2024 08/26/2024
Occupancy Inspection - Codes Commercial Full C of O 8/30/2024 8/30/2024 08/30/2024
Occupancy Inspection - Fire Passed 8/30/2024 8/30/2024 08/30/2024
Documents & Images
Date Uploaded File Type Document Name
06/13/2024 Application Form APPLICATION
06/13/2024 Plans 240530 Safire - Permit CD
06/13/2024 Letter License Tax Bill
07/03/2024 Approved Plans Approved building plans
07/03/2024 Email Safire Building Permit PRCOM20243058
07/03/2024 Receipt Receipt for transaction:2024-005510
07/10/2024 Letter DS Building Permit
07/16/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter Codes Final Certificate of Occupancy
08/30/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: