Permit Application Status

PRCOM20220891


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20220891
Building Permit - Commercial
Certificate of Occupancy
NEW MULTI-FAMILY
NEW 4 UNIT TOWNHOMES **Approved plans are in PRCOM20214607
03/10/2022
04/29/2022
07/28/2023
Locations
Contacts
BRINKMANN CONSTRUCTORS, Address:16650 CHESTERFIELD GROVE RD, Phone:(636) 537-9700  
nwintjen@brinkmannconstructors.com, Address:nwintjen@brinkmannconstructors.com  
ALDEN PLUMBING & MECHANICAL LLC, Address:5600 W 95TH ST STE307, Phone:(816) 666-8662  
KASA ELECTRIC LLC, Address:1206 NW VALLEY RIDGE DR, Phone:(816) 228-4886  
TRI Architects, Address:9812 Manchester rd, Phone:(314) 395-9750  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/29/2022
Joe Frogge
Building Plan Review Approved 04/29/2022
Joe Frogge
Licensed Contractors Approved 09/17/2021 03/10/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Multi-Family $5,496.86 $5,496.86 Paid 04/19/2022
8331507-Sewer Connection Fee $1,320.00 $1,320.00 Paid 04/19/2022
7232302-Residential License Tax Fee $2,437.12 $2,437.12 Paid 04/19/2022
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 04/19/2022
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 04/19/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/15/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/14/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/27/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 7/13/2022 (9:15) 7/13/2022 07/13/2022
Miscellaneous Correction
Corrective Action Required
07/13/2022
Building 1012-1018 North ,East, South sides are ready to pour
Footing Inspection - Commercial Partial 7/20/2022 (10:45) 7/20/2022 07/20/2022
Miscellaneous Correction
Corrective Action Required
07/13/2022
Building 1012-1018 Main building footings complete
Underslab Plumbing Inspection - Commercial Passed 8/10/2022 08/10/2022
Underslab Electrical Inspection - Commercial Passed 8/11/2022 8/11/2022 08/11/2022
Sewer Service Inspection Passed 08/31/2022
Misc
Informational
08/31/2022
Miller Plumbing installed sewer connection using SDR26 4” pipe and fittings going into 6” connection to 6” wye on main. 8/31/22 ES
Electrical Service Inspection Passed 11/23/2022 11/23/2022 11/23/2022
Misc
Informational
11/23/2022
OK TO RELEASE METERS FOR FOLLOWING UNITS UNIT 1012 UNIT 1014 UNIT 1016 UNIT 1018 1 HOUSE PANEL BLDG # 8
All Rough Inspection - Commercial Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
Protect dryer duct 2" below plate line throughout 1012-strap top plate at master 1014-dryer duct 1016-dryer duct 1018-Set screws at holddowns in master closet and back bed, seal fireblocking at ceiling line in master, provide bonding screw and jumper at exterior box
All Rough Inspection - Commercial Passed 12/1/2022 12/1/2022 12/01/2022
Misc
Resolved
12/01/2022
Protect dryer duct 2" below plate line throughout 1012-strap top plate at master 1014-dryer duct 1016-dryer duct 1018-Set screws at holddowns in master closet and back bed, seal fireblocking at ceiling line in master, provide bonding screw and jumper at exterior box
Occupancy Inspection - Codes Commercial Failed 4/17/2023 4/17/2023 04/17/2023
Misc
Corrective Action Required
04/17/2023
Complete final grade, sod, roof drainage and extensions 1014-Stair risers to be within 3/8” variance 1016-Stair risers to be within 3/8” variances exterior gfci not working 1018-Stair risers to be within 3/8” variance
Occupancy Inspection - Codes Commercial Ready for Temp CO 4/18/2023 4/18/2023 04/18/2023
Misc
Corrective Action Required
04/17/2023
Complete final grade, sod, roof drainage and extensions, recheck meters after final grade
Occupancy Inspection - Codes Commercial Ready for Temp CO 6/14/2023 06/14/2023
Misc
Corrective Action Required
04/18/2023
Complete final grade, sod, roof drainage and extensions, recheck meters after final grade
Occupancy Inspection - Codes Commercial Ready for Temp CO 7/14/2023 07/14/2023
Misc
Corrective Action Required
06/14/2023
Complete final grade, sod, roof drainage and extensions, recheck meters after final grade
Erosion Control Inspection Residential Passed 07/28/2023
Footing Inspection - Commercial Passed 07/28/2023
Miscellaneous Correction
Resolved
07/28/2023
Building 1012-1018 Main building footings complete
Rated Assembly Inspection Passed 07/28/2023
Rated Assembly Inspection Passed 07/28/2023
Erosion Control Inspection Residential Passed 07/28/2023
Water Service Inspection Passed 07/28/2023
Occupancy Inspection - Codes Commercial Full C of O 07/28/2023
Misc
Resolved
07/28/2023
Complete final grade, sod, roof drainage and extensions, recheck meters after final grade
Documents & Images
Date Uploaded File Type Document Name
04/19/2022 Receipt Receipt for transaction:2022-002185
04/29/2022 Letter DS Building Permit
06/01/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
11/23/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
05/15/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/15/2023 Receipt Receipt for transaction:2023-003300
06/14/2023 Substantial Completion and TCO Extension Request_prcom20220891 - 6_14_23
06/14/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/14/2023 Receipt Receipt for transaction:2023-004397
06/14/2023 Substantial Completion and TCO Extension Request_prcom20220891 - 6_14_23
07/27/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/27/2023 Receipt Receipt for transaction:2023-005857
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter Codes Final Certificate of Occupancy
07/28/2023 Letter Field Certificate of Occupancy
01/02/2024 Codes Temporary Certificate of Occupancy195
01/02/2024 Codes Temporary Certificate of Occupancy234
01/02/2024 Codes Temporary Certificate of Occupancy263
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home