PRCOM20215283


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20215283
Building Permit - Commercial
Certificate of Occupancy
CHAPEL RIDGE TOWNHOMES LLC
NEW MULTI-FAMILY
NEW 5PLEX
10/08/2021
08/26/2022
06/21/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:4301 INDIAN CREEK PKWY, Phone:(913) 451-9390  
CHAPEL RIDGE TOWNHOMES LLC, Address:3701 NE AKIN DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/07/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $2,343.55 $2,343.55 Paid 08/24/2022
8331507-Sewer Connection Fee $1,650.00 $1,650.00 Paid 08/24/2022
7232302-Residential Excise Tax Fee $3,046.40 $3,046.40 Paid 08/24/2022
9110078-Valuation Fee for New Multi-Family $4,135.71 $4,135.71 Paid 08/24/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 9/8/2022 (2:30) 9/8/2022 09/08/2022
Underslab Plumbing Inspection - Commercial Passed 9/16/2022 9/16/2022 09/16/2022
Rated Assembly Inspection Partial 12/5/2022 12/5/2022 12/05/2022
Misc
Corrective Action Required
12/05/2022
Attic firewall-1st layer OK
Gas Service Inspection - Commercial Failed 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
01/17/2023
-Not ready
Electrical Service Inspection Passed 1/17/2023 1/17/2023 01/17/2023
All Rough Inspection - Commercial Failed 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
01/17/2023
UNIT A: -Shim gap at stoop roof beam support at garage wall -Bond gas piping -Fb wall plate penetrations throughout; Fb half bathroom wall -Protect wiring within six ft of attic access -Protect laundry plumbing; fully nail stud shoe UNIT B: -Fb wall plate penetrations throughout -Complete electrical to rear bathroom receptacle -Support vent in attic per code UNIT C: -Fb wall plate penetrations throughout; Fb half bathroom wall -Support plumbing above kitchen -Support vent in attic per code UNIT D: -Fb wall plate penetrations throughout; Fb half bathroom wall -Protect plumbing at half bathroom/kitchen wall -Support plumbing above kitchen -Strap top plates at AC line; protect AC line -Reinstall LIB strap at master bathroom -Support vent in attic per code UNIT E: -Shim gap at stoop roof beam support at garage wall -Fb wall plate penetrations throughout; Fb half bathroom wall -Reinstall LIB strap at master bedroom -Provide insulation shield for b-vent to insulation level -Strap wall top plates at rear bedroom closet **DO NOT INSULATE
All Rough Inspection - Commercial Failed 1/19/2023 1/19/2023 01/19/2023
Misc
Corrective Action Required
01/17/2023
UNIT A: -Fully nail stud shoe UNIT B: -Support vent in attic per code -Roof leak at 3” vent roof flashing above rear bathroom UNIT C: -Support plumbing above kitchen -Support vent in attic per code UNIT D: -Support plumbing above kitchen -Support vent in attic per code UNIT E: **OK TO INSULATE
Gas Service Inspection - Commercial Failed 1/19/2023 1/19/2023 01/19/2023
Misc
Corrective Action Required
01/17/2023
-Unit A, provide min 10 psi gas test pressure
Gas Service Inspection - Commercial Failed 1/24/2023 1/24/2023 01/24/2023
Misc
Corrective Action Required
01/19/2023
-Unit A, provide min 10 psi gas test pressure
All Rough Inspection - Commercial Failed 1/24/2023 1/24/2023 01/24/2023
Misc
Corrective Action Required
01/19/2023
UNIT A: UNIT B: -Support 3” vent in attic per code UNIT C: UNIT D: UNIT E:
Rated Assembly Inspection Partial 2/3/2023 2/3/2023 02/03/2023
Misc
Corrective Action Required
12/05/2022
Attic firewall-2nd layer OK Dwelling firewall-1st layer ok
All Rough Inspection - Commercial Passed 2/8/2023 2/8/2023 02/08/2023
Misc
Resolved
02/08/2023
UNIT A: UNIT B: -Support 3” vent in attic per code UNIT C: UNIT D: UNIT E:
Gas Service Inspection - Commercial Passed 2/8/2023 2/8/2023 02/08/2023
Misc
Resolved
02/08/2023
-Unit A, provide min 10 psi gas test pressure
Rated Assembly Inspection Passed 2/15/2023 2/15/2023 02/15/2023
Misc
Resolved
02/15/2023
Attic firewall-2nd layer OK Dwelling firewall-1st layer ok
Occupancy Inspection - Codes Commercial Failed 5/15/2023 5/15/2023 05/15/2023
Misc
Corrective Action Required
05/15/2023
EXTERIOR: -Exterior not completed at this time UNIT A: -Master bedroom smoke alarm not interconnected -Install connector at NM entry into furnace UNIT B: -Install switch cover plate under kitchen island -Tighten laundry receptacle -Install connector at NM entry into furnace UNIT C: -Install furnace switch cover plate -Install connector at NM entry into furnace UNIT D: -Replace broken window -Garage light not working -Install connector at NM entry into furnace UNIT E: -Install kitchen island receptacle cover plate -Install connector at NM entry into furnace
Occupancy Inspection - Codes Commercial Ready for Temp CO 5/16/2023 5/16/2023 05/16/2023
Misc
Corrective Action Required
05/15/2023
EXTERIOR: -Exterior not completed at this time UNIT E: -Install kitchen island receptacle cover plate -Install connector at NM entry into furnace **TCO APPROVED FOR UNITS A TO D
Occupancy Inspection - Codes Commercial Failed 5/17/2023 5/17/2023 05/17/2023
Misc
Corrective Action Required
05/16/2023
EXTERIOR: -Exterior not completed at this time -PAY ALL FEES BEFORE ANY OCCUPANCY IS ISSUED **TCO APPROVED FOR UNITS A TO E
Occupancy Inspection - Codes Commercial Full C of O 6/21/2023 06/21/2023
Misc
Resolved
06/21/2023
EXTERIOR: -Exterior not completed at this time -PAY ALL FEES BEFORE ANY OCCUPANCY IS ISSUED **TCO APPROVED FOR UNITS A TO E
Documents & Images
Date Uploaded File Type Document Name
08/24/2022 Receipt Receipt for transaction:2022-006945
08/26/2022 Letter DS Building Permit
09/08/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
12/05/2022 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/19/2023 Letter INSPECTION SUMMARY
01/19/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
02/03/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/17/2023 Letter INSPECTION SUMMARY
06/02/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/02/2023 Receipt Receipt for transaction:2023-003915
06/21/2023 Letter Codes Final Certificate of Occupancy
06/21/2023 Letter Field Certificate of Occupancy
06/21/2023 Letter INSPECTION SUMMARY
12/20/2023 Codes Temporary Certificate of Occupancy222
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home