Permit Application Status

PRCOM20215272


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20215272
Building Permit - Commercial
Certificate of Occupancy
CHAPEL RIDGE TOWNHOMES LLC
NEW MULTI-FAMILY
NEW 4PLEX
10/08/2021
08/25/2022
06/19/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:4301 INDIAN CREEK PKWY, Phone:(913) 451-9390  
CHAPEL RIDGE TOWNHOMES LLC, Address:3701 NE AKIN DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/07/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $1,874.84 $1,874.84 Paid 08/24/2022
8331507-Sewer Connection Fee $1,320.00 $1,320.00 Paid 08/24/2022
7232302-Residential Excise Tax Fee $2,437.12 $2,437.12 Paid 08/24/2022
9110078-Valuation Fee for New 3 or 4 Family $2,251.12 $2,251.12 Paid 08/24/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rated Assembly Inspection Partial 10/26/2022 10/26/2022 10/26/2022
Misc
Corrective Action Required
10/26/2022
Attic separation wall-1st layer ok
Electrical Service Inspection Passed 12/6/2022 12/6/2022 12/06/2022
Gas Service Inspection - Commercial Passed 12/6/2022 12/06/2022
All Rough Inspection - Commercial Failed 12/6/2022 12/6/2022 12/06/2022
Misc
Corrective Action Required
12/06/2022
**For boxes other than Allied Moulded boxes, provide information for min separation UNIT A: -Vent all bathroom fans to outdoor -Strap top plate cut more than 50% and protect AC line at closet top wall plate -Nail together girder truss above master bedroom -Fb wall plate penetrations at master bathroom UNIT B: -Fill in gap at front door hinges per security code -Vent all bathroom fans to outdoor -Complete master shower plumbing -Protect AC line at living room top wall plate -Fb AC line penetration of bedroom bottom wall plate -Support for plumbing vent above laundry not attached to framing UNIT C: -Fill in gap at front door hinges per security code -Vent all bathroom fans to outdoor -Complete master shower plumbing -Support for plumbing vent above laundry not attached to framing -Support vent above master bathroom -Slope b-vent in attic min 1/4” per ft -Have truss engineer address fix for broken truss above master bedroom UNIT D: -Vent all bathroom fans to outdoor -Extend supply duct above kitchen to ceiling level -Protect wiring at stair wall -Strap top plate cut more than 50% and protect AC line at closet top wall plate -Seal at plumbing vent roof flashing -Nail together girder truss above master bedroom; fasten down girder truss to wall -Fb top wall plate penetrations in master bedroom and bathroom. I’m being doing a lot of this lately so I don’t have to write down. Please have the foaming guy be more attentive **OK TO INSULATE
Rated Assembly Inspection Partial 12/6/2022 12/06/2022
Misc
Corrective Action Required
10/26/2022
Attic separation wall-2nd layer ok
All Rough Inspection - Commercial Failed 12/20/2022 12/20/2022 12/20/2022
Misc
Corrective Action Required
12/06/2022
UNIT A: UNIT B: -Complete master shower plumbing -Support for plumbing vent above laundry not attached to framing UNIT C: -Complete master shower plumbing UNIT D: -Seal at plumbing vent roof flashing
All Rough Inspection - Commercial Passed 12/28/2022 12/28/2022 12/28/2022
Misc
Resolved
12/28/2022
UNIT A: UNIT B: -Complete master shower plumbing -Support for plumbing vent above laundry not attached to framing UNIT C: -Complete master shower plumbing UNIT D: -Seal at plumbing vent roof flashing
Rated Assembly Inspection Partial 1/9/2023 1/9/2023 01/09/2023
Misc
Corrective Action Required
12/06/2022
Attic separation wall-2nd layer ok Dwelling firewall- 1st layer ok **provide 2 layers of fire rock at attic separation wall above garage (B unit) ; close hole
Rated Assembly Inspection Passed 1/23/2023 1/23/2023 01/23/2023
Misc
Resolved
01/23/2023
Attic separation wall-2nd layer ok Dwelling firewall- 1st layer ok **provide 2 layers of fire rock at attic separation wall above garage (B unit) ; close hole
Occupancy Inspection - Codes Commercial Failed 4/28/2023 4/28/2023 04/28/2023
Misc
Corrective Action Required
04/28/2023
3679 NE Akin -check caulk/sealant at all exterior wall penetrations Unit A -breaker for disposal malfunctioning -breaker for island plugs malfunctioning Unit B -self closing hinges at garage door needs adjusted, doesn't close all the way Unit C -missing switch plate cover for garbage disposal Unit D -missing switch plate cover for garbage disposal -self closing hinges at garage door needs adjusted, doesn't close all the way
Occupancy Inspection - Codes Commercial Ready for Temp CO 5/1/2023 5/1/2023 05/01/2023
Misc
Corrective Action Required
04/28/2023
Exterior : -Check caulk/sealant at all exterior wall penetrations -Final grade, Sod, splash blocks
Occupancy Inspection - Codes Commercial Full C of O 6/19/2023 06/19/2023
Misc
Resolved
06/19/2023
Exterior : -Check caulk/sealant at all exterior wall penetrations -Final grade, Sod, splash blocks
Documents & Images
Date Uploaded File Type Document Name
08/24/2022 Receipt Receipt for transaction:2022-006945
08/25/2022 Letter DS Building Permit
10/26/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
12/28/2022 Letter INSPECTION SUMMARY
12/28/2022 Engineer Report/Study I55657730.220312-A repair for B2
01/09/2023 Letter INSPECTION SUMMARY
01/23/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
06/02/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/02/2023 Receipt Receipt for transaction:2023-003915
06/19/2023 Letter Codes Final Certificate of Occupancy
06/19/2023 Letter Field Certificate of Occupancy
12/20/2023 Codes Temporary Certificate of Occupancy213
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home