Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 09/02/2020 08/21/2020
Joe Frogge
IBC 1809.5 Frost protection - foundation
Corrective Action Required
08/21/2020

2018 IBC 1809.5 Frost protection. Except where otherwise protected from frost, foundations and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extending below the frost line of the locality; 2. Constructing in accordance with ASCE 32; or 3. Erecting on solid rock. (see code section for exceptions) Shallow foundations shall not bear on frozen soil unless such frozen condition is of a permanent character. Action required: Comment is for informational purposes. Minimum depth of piers is 36". To be verified in field.
Licensed Contractors Approved 09/02/2020 08/20/2020
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $135.00 $135.00 Paid 08/24/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Partial 9/2/2020 09/03/2020
Misc
Corrective Action Required
09/02/2020
Steve Thomas the the city contract
Underground Electrical Inspection - Commercial Partial 9/3/2020 09/03/2020
Misc
Informational
09/03/2020
- UNDERGROUND CONDUIT FROM EAST PICNIC SHELTER TO WEST PICNIC SHELTER -
Piers/Caissons Inspection - Commercial Partial 9/3/2020 (11:15) 9/3/2020 09/03/2020
Misc
Informational
09/03/2020
- EAST PICNIC SHELTER - - (4) 36 X 36 PIERS W/ (8) # 6 VERT BARS WRAPED WITH # 4 TIES 12 OC W/ 2 TIES IN TOP 5", DRIVEN GROUND ROD ON NE PIER -
Piers/Caissons Inspection - Commercial Passed 9/14/2020 09/14/2020
Misc
Informational
09/14/2020
- EAST PICNIC SHELTER - - (4) 36 X 36 PIERS W/ (8) # 6 VERT BARS WRAPED WITH # 4 TIES 12 OC W/ 2 TIES IN TOP 5", DRIVEN GROUND ROD ON NE PIER - - WEST PICNIC SHELTER - - (4) 36 X 36 PIERS W/ (8) #6 VERT BARS WRAPED W/ #4 TIES 12" OC W/ 2 TIES IN TOP 5" DRIVEN GROUND ROD IN NW PIER -
Footing Inspection - Commercial Passed 9/14/2020 (1:00) 9/14/2020 09/14/2020
Misc
Informational
09/14/2020
- USED DRILLED PIER FOOTING OPTION PER PLAN -
Investigation Inspection Complete 3/13/2021 03/15/2021
Misc
Informational
03/15/2021
- NO FINAL BUILDING INSPECTION PERFORMED - - EMAILED 180 DAY LETTER -
Underground Electrical Inspection - Commercial Passed 4/14/2022 04/14/2022
Misc
Informational
09/03/2020
- UNDERGROUND CONDUIT FROM EAST PICNIC SHELTER TO WEST PICNIC SHELTER -
Underslab Electrical Inspection - Commercial Passed 4/14/2022 04/14/2022
Rough Electrical Inspection - Commercial Passed 4/14/2022 04/14/2022
Retaining Wall Inspection Passed 4/14/2022 04/14/2022
Misc
Informational
09/03/2020
- EAST PICNIC SHELTER - - (4) 36 X 36 PIERS W/ (8) # 6 VERT BARS WRAPED WITH # 4 TIES 12 OC W/ 2 TIES IN TOP 5", DRIVEN GROUND ROD ON NE PIER -
Miscellaneous Inspection Passed 4/14/2022 04/14/2022
Misc
Corrective Action Required
09/03/2020
Steve Thomas the the city contract HE SHOULD CALL IN HIS INSPECTIONS THEN
Final Inspection - Commercial Passed 4/14/2022 04/14/2022
Verify Final Inspection (Final) Complete 4/14/2022 04/14/2022
Documents & Images
Date Uploaded File Type Document Name
08/19/2020 Application Form lowenstein permit application
08/21/2020 Email email from planner
08/21/2020 Engineer Report/Study 65979- CAL SEALED
08/21/2020 Approved Plans Approved plans
08/24/2020 Receipt Receipt for transaction: 2020-005591
08/24/2020 Letter DS Building Permit
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
02/01/2021 Letter Codes 140 Day Letter
03/15/2021 Letter Codes 180 Day Letter
09/17/2021 Letter Codes 180 Day Letter
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home