Summary
PRCOM20200319
Building Permit - Commercial
Final Completion
EVANS JOHN S & AR AM I LP
ALTERATION COMMERCIAL
FACADE REMODEL WITH LIGHTING **drawing is in plan review file
02/11/2020
02/19/2020
08/06/2020
Locations
Contacts
BUILDERS SCREEN AND ALUMINUM, Address:905 PETTY DR, Phone:(573) 374-4114  
NICKELL ELECTRIC COMPANY INC, Address:1606 MAIN ST, Phone:(816) 246-8797  
BSE STRUCTURAL ENGINEERS LLC, Address:11320 WEST 79TH ST, Phone:(913) 492-7400  
EVANS JOHN S & AR AM I LP, Address:208 SW ASPEN  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 02/24/2020 02/14/2020
Joe Frogge
Fire Plan Review Approved 02/24/2020 02/12/2020
Michael Weissenbach
Building Plan Review Approved 02/24/2020 02/12/2020
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $60.00 $60.00 Paid 02/19/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Electrical Inspection - Commercial Failed 7/23/2020 7/23/2020 at 2:40 PM 07/23/2020
Misc
Corrective Action Required
07/23/2020
THE WHOLE ELECTRICAL INSTALLATION (LIGHTS AND WIRING) IS ALREADY COVERED PRIOR TO INSPECTION. ALSO NEED PLAN ON SITE. I ATTEMPTED TO CONTACT KIM BUT UNSUCCESSFUL.
Final Electrical Inspection - Commercial Failed 7/28/2020 at 9:05 AM 07/28/2020
Misc
Corrective Action Required
07/23/2020
THE WHOLE ELECTRICAL INSTALLATION (LIGHTS AND WIRING) IS ALREADY COVERED PRIOR TO INSPECTION. ALSO NEED PLAN ON SITE. I ATTEMPTED TO CONTACT KIM BUT UNSUCCESSFUL.
Misc
Corrective Action Required
07/28/2020
-INSIDE COLUMN LIGHTED FACADE, SECURE MC CABLE WITHIN 12" OF J-BOX
Final Electrical Inspection - Commercial Passed 8/5/2020 8/5/2020 08/05/2020
Misc
Resolved
08/05/2020
THE WHOLE ELECTRICAL INSTALLATION (LIGHTS AND WIRING) IS ALREADY COVERED PRIOR TO INSPECTION. ALSO NEED PLAN ON SITE. I ATTEMPTED TO CONTACT KIM BUT UNSUCCESSFUL.
Misc
Resolved
08/05/2020
-INSIDE COLUMN LIGHTED FACADE, SECURE MC CABLE WITHIN 12" OF J-BOX
Documents & Images
Date Uploaded File Type Document Name
02/11/2020 Letter License Tax Not Applicable
02/12/2020 Letter Fire Building Plan Review
02/19/2020 Receipt Receipt for transaction: 2020-000694
02/19/2020 Letter DS Building Permit
07/23/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
08/05/2020 Letter Codes Plan Review Conditions
08/05/2020 Letter Codes 140 Day Letter
08/05/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home