Permit Application Status

PRCOM20200305


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20200305
Building Permit - Commercial
Certificate of Occupancy
LANGSFORD DEVELOPMENT INC
CHANGE OF TENANT
TENANT FINISH FOR COFFEE SHOP WITH CHILDRENS PLAY AREA AND PRE-PACKAGED FOODS **drawing is in plan review file
02/10/2020
02/28/2020
08/23/2020
04/10/2020
Locations
Contacts
LANGSFORD DEVELOPMENT INC, Address:616 SW 3RD ST  
PACT CONSTRUCTION SERVICES, Address:1280 NE DELTA SCHOOL RD, Phone:(816) 287-3030  
FUTUNE STOMES, Address:6800 NOLAND RD, Phone:(816) 519-5981  
THREE TRAILS HEATING COOLING, Address:13223 S 71 HWY, Phone:(816) 701-6377  
ECO ELECTRIC, Address:426 GRANITE DR, Phone:(816) 698-2887  
PROLINE PLUMBING, Address:2020 SW HUNTBROOK TER, Phone:(816) 442-9653  
JEREMY@PACTKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 02/27/2020 02/27/2020
Joe Frogge
Building Plan Review Approved with Conditions 03/05/2020 02/27/2020
Joe Frogge
Miscellaneous Correction
Corrective Action Required
02/27/2020

License tax A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 2/25/20 - acknowledged in letter
Health Dept Inspection
Corrective Action Required
02/27/2020

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 2/25/20 - acknowledged in letter
IBC 1004.9 Posting of occupant load
Corrective Action Required
02/27/2020

2018 IBC 1004.9 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Action required: Comment is for informational purposes. To be field verified. 2/25/20 - acknowledged in letter
Misc
Corrective Action Required
02/27/2020

Inadequate information to complete review. Action required: Provide complete MEP design that includes, but is not limited to: - - - Backflow prevention at required plumbing locations. 2/25/20 - acknowledged in letter. to be field verified - Indirect drains at required plumbing locations. 2/27/20 - field verify
IBC 1209.2 Finish materials
Corrective Action Required
02/27/2020

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) 1209.2.3 Showers. (see code for details) 1209.2.4 Waterproof joints. (see code for details) Action required: specify compliant materials at walls surrounding toilet and mop sink. 2/25/20 - acknowledged in letter. Field verify.
Fire Plan Review Approved with Conditions 03/05/2020 02/27/2020
Michael Weissenbach
Posting of occupant load
Corrective Action Required
02/27/2020

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post Occupant load sign at 91
Address numbers required
Corrective Action Required
02/27/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior doors
Portable fire extinguishers - conspicuous locations
Resolved
02/27/2020

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide one 2A10BC Fire Extinguisher
Panic and fire exit hardware
Corrective Action Required
02/27/2020

2018 IFC 1010.1.10 Panic and fire exit hardware. Doors serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock unless it is a panic hardware or fire exit hardware. (Verified At Inspection)
Building Plan Review Rejected 02/27/2020 02/25/2020
Joe Frogge
Miscellaneous Correction
Corrective Action Required
02/20/2020

License tax A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 2/25/20 - acknowledged in letter
Health Dept Review
Resolved
02/23/2020

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
02/20/2020

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 2/25/20 - acknowledged in letter
IBC 1004.9 Posting of occupant load
Corrective Action Required
02/20/2020

2018 IBC 1004.9 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Action required: Comment is for informational purposes. To be field verified. 2/25/20 - acknowledged in letter
Misc
Corrective Action Required
02/20/2020

Inadequate information to complete review. Action required: Provide complete MEP design that includes, but is not limited to: - Outdoor air calculations and method of delivery. 2/25/20 - Outdoor air calcs for white box space (as noted in letter) are different than those for an assembly occupancy. - - Backflow prevention at required plumbing locations. 2/25/20 - acknowledged in letter. to be field verified - Indirect drains at required plumbing locations. 2/25/20 - Sheet A1.2 specifically notes 3-compartment sink as direct connected.
IBC 1209.2 Finish materials
Corrective Action Required
02/20/2020

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) 1209.2.3 Showers. (see code for details) 1209.2.4 Waterproof joints. (see code for details) Action required: specify compliant materials at walls surrounding toilet and mop sink. 2/25/20 - acknowledged in letter. Field verify.
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Resolved
02/25/2020

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of coffee bar swing gate.
IBC 1005.7 Encroachment
Resolved
02/25/2020

2018 IBC 1005.7 Encroachment. Encroachments into the required means of egress width shall be in accordance with the provisions of this section. 1005.7.1 Doors. Doors, when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than one-half. (see code for exceptions) Action required: Modify design so that door out of existing toilet room does not block required exit.
Health Department Review Approved 02/23/2020
Joe Frogge
Fire Plan Review Approved with Conditions 02/27/2020 02/20/2020
Michael Weissenbach
Posting of occupant load
Corrective Action Required
02/20/2020

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post Occupant load sign at 91
Address numbers required
Corrective Action Required
02/20/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior doors
Portable fire extinguishers - conspicuous locations
Corrective Action Required
02/20/2020

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide one 2A10BC Fire Extinguisher
Panic and fire exit hardware
Corrective Action Required
02/20/2020

2018 IFC 1010.1.10 Panic and fire exit hardware. Doors serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock unless it is a panic hardware or fire exit hardware. (Verified At Inspection)
Illumination required
Resolved
02/20/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Action Required) Provide plan for emergency/exit lighting. Exterior emergency illumination required at both exits.
Licensed Contractors Approved 02/27/2020 02/20/2020
Joe Frogge
LC - General Contractor
Corrective Action Required
02/20/2020

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
02/20/2020

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Licensed Contractors Approved 02/21/2020 02/20/2020
Kim Brennan
LC - General Contractor
Corrective Action Required
02/12/2020

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
02/12/2020

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Building Plan Review Rejected 02/21/2020 02/12/2020
Joe Frogge
Miscellaneous Correction
Corrective Action Required
02/12/2020

License tax A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Health Dept Review
Corrective Action Required
02/12/2020

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
02/12/2020

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
IBC 1004.9 Posting of occupant load
Corrective Action Required
02/12/2020

2018 IBC 1004.9 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Action required: Comment is for informational purposes. To be field verified.
Misc
Corrective Action Required
02/12/2020

Inadequate information to complete review. Action required: Provide complete MEP design that includes, but is not limited to: - Outdoor air calculations and method of delivery. - Exit and emergency lighting. - Backflow prevention at required plumbing locations. - Indirect drains at required plumbing locations.
IBC 1209.2 Finish materials
Corrective Action Required
02/12/2020

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) 1209.2.3 Showers. (see code for details) 1209.2.4 Waterproof joints. (see code for details) Action required: specify compliant materials at walls surrounding toilet and mop sink.
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Corrective Action Required
02/12/2020

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of coffee bar swing gate.
IBC 1005.7 Encroachment
Corrective Action Required
02/12/2020

2018 IBC 1005.7 Encroachment. Encroachments into the required means of egress width shall be in accordance with the provisions of this section. 1005.7.1 Doors. Doors, when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than one-half. (see code for exceptions) Action required: Modify design so that door out of existing toilet room does not block required exit.
Fire Plan Review Rejected 02/21/2020 02/12/2020
Michael Weissenbach
Posting of occupant load
Corrective Action Required
02/12/2020

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post Occupant load sign at 91
Address numbers required
Corrective Action Required
02/12/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior doors
Portable fire extinguishers - conspicuous locations
Corrective Action Required
02/12/2020

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Action Required) Provide one 2A10BC Fire Extinguisher
Panic and fire exit hardware
Corrective Action Required
02/12/2020

2018 IFC 1010.1.10 Panic and fire exit hardware. Doors serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock unless it is a panic hardware or fire exit hardware. (Action Required) Provide panic hardware for existing storefront door.
Illumination required
Corrective Action Required
02/12/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Action Required) Provide plan for emergency/exit lighting. Exterior emergency illumination required at both exits.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $180.00 $180.00 Paid 02/28/2020
8331507-Sewer Connection Fee $150.00 $150.00 Paid 02/28/2020
7232302-Commercial Excise Tax Fee $24,517.50 $24,517.50 Paid 04/07/2020
$0.00
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Passed 3/3/2020 3/3/2020 at 3:05 PM 03/03/2020
Underslab Plumbing Inspection - Commercial Failed 3/9/2020 03/09/2020
Misc
Corrective Action Required
03/09/2020
gravel and bed all under slab plumbing and recall for inspection.
Underslab Plumbing Inspection - Commercial Passed 3/11/2020 03/11/2020
Misc
Corrective Action Required
03/09/2020
gravel and bed all under slab plumbing and recall for inspection.
Rough Electrical Inspection - Commercial Failed 3/19/2020 3/19/2020 03/19/2020
Misc
Corrective Action Required
03/19/2020
Conductors above drop ceiling shall be in MC Seal up ward penetrations
Rough Plumbing Inspection - Commercial Partial 3/19/2020 3/19/2020 03/19/2020
Misc
Informational
03/19/2020
Behind counter, restroom
Rough Electrical Inspection - Commercial Failed 3/20/2020 3/20/2020 03/20/2020
Misc
Corrective Action Required
03/19/2020
Conductors above drop ceiling shall be in MC check at above ceiling inspection
Occupancy Inspection - Fire Temporary C of O 3/30/2020 03/30/2020
Above Ceiling Inspection Passed 03/30/2020
Occupancy Inspection - Codes Commercial Failed 3/30/2020 3/30/2020 03/30/2020
Misc
Corrective Action Required
03/30/2020
- install vertical grab bar, TP,Mirror in rest room. -gfci outlets required left of sink and under counter at ice machine. - back flows on all hard piped fixtures to water piping. - License tax needs to be paid before TCO or COFO>
Occupancy Inspection - Fire Passed 3/31/2020 03/31/2020
Occupancy Inspection - Codes Commercial Failed 4/6/2020 4/6/2020 04/06/2020
Misc
Corrective Action Required
03/30/2020
- install vertical grab bar, TP,Mirror in rest room. -gfci outlets required left of sink and under counter at ice machine. - back flows on all hard piped fixtures to water piping. - License tax needs to be paid before TCO or COFO> No lock box code , tax not paid, no inspection
Occupancy Inspection - Codes Commercial Failed 4/7/2020 4/7/2020 04/07/2020
Misc
Corrective Action Required
04/06/2020
- Provide ADA compliant mirror. - License tax needs to be paid before TCO or COFO> No lock box code , tax not paid, no inspection
Occupancy Inspection - Codes Commercial Failed 4/8/2020 4/8/2020 04/08/2020
Misc
Corrective Action Required
04/07/2020
- License tax needs to be paid before TCO or COFO>
Occupancy Inspection - Codes Commercial Full C of O 4/13/2020 4/10/2020 04/10/2020
Misc
Resolved
04/10/2020
- License tax needs to be paid before TCO or COFO>
Documents & Images
Date Uploaded File Type Document Name
02/11/2020 LT info
02/12/2020 Letter Fire Building Plan Review
02/12/2020 cost eval
02/12/2020 Letter DS P/R Corrections Document
02/20/2020 Letter Fire Building Plan Review
02/23/2020 New Food Establishment Plan Review - Approved FTG 0001841
02/25/2020 Letter DS P/R Corrections Document
02/27/2020 Letter Fire Building Plan Review
02/27/2020 Letter License Tax Bill
02/28/2020 Receipt Receipt for transaction: 2020-000882
02/28/2020 Letter DS Building Permit
03/03/2020 Letter INSPECTION SUMMARY
03/09/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
03/19/2020 Letter INSPECTION SUMMARY
03/19/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter INSPECTION SUMMARY
04/07/2020 Receipt Receipt for transaction:2020-001425
04/10/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents