Summary
PRCOM20191742
Building Permit - Commercial
Certificate of Occupancy
PINE TREE PLAZA LLC
CHANGE OF TENANT
TENANT FINISH FOR TEACHING COMPUTER CLASSES
07/02/2019
07/18/2019
01/06/2020
08/22/2019
Locations
Contacts
MUDLOFF CONSTRUCTION LLC, Address:1917 E SPRUCE ST, Phone:(913) 393-0737  
JOE STEWART ARCHITECT, Address:4731 NORTH CLEVELAND AVE, Phone:(816) 830-2754  
TOP NOTCH INC, Address:23754 W 82ND TERR, Phone:(913) 441-8900  
LAKE ELECTRIC LLC, Address:1917 SPRUCE ST, Phone:(913) 490-8377  
TRADEMARK PLUMBING LLC, Address:611 NW 105TH RD, Phone:(816) 824-5846  
  
PINE TREE PLAZA LLC, Address:601 E SOUTH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved 07/17/2019 07/17/2019
Joe Frogge
Bldg - Premises identification/address 501.2
Resolved
07/15/2019

2012 IBC 501.2 – Premises identification. New and existing buildings shall have approved numbers or letters. Each character shall not be less than 3 inches high with a minimum stroke width of 0.5 inch. They should be installed on a contrasting background and be plainly legible and visible from the street or road fronting the property. When required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers and letters shall be Arabic numbers or alphabetical letters. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address numbers shall be maintained. In multi-tenant commercial buildings where tenants have multiple entrances located on different sides of the building, each door shall be addressed. Address characters shall be capable of being illuminated by an internal or external lighting source. Action required: Update records to show correct address which is 314 SW Blue Pkwy.
Bldg - Toilet room wall finish 1210.2.2
Resolved
07/15/2019

1209.2.2 Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and Actions required: - Specify compliant wall finish materials at mop sink. - Raise tile around water closets to 48" at details on sheets A2 & A4.
Licensed Contractors Rejected 07/17/2019 07/15/2019
Joe Frogge
LC - MEP Subs
Resolved
07/17/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 7/15/19 - acknowledged in letter
Fire Plan Review Approved with Conditions 07/17/2019 07/11/2019
Michael Weissenbach
Address numbers required
Corrective Action Required
07/10/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address front and back doors 314
Portable fire extinguishers - conspicuous locations
Corrective Action Required
07/10/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide one 2A10BC Extiguisher
Door operations
Corrective Action Required
07/10/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (Verified At Inspection)
Building Plan Review Rejected 07/15/2019 07/10/2019
Joe Frogge
Bldg - Premises identification/address 501.2
Corrective Action Required
07/10/2019

2012 IBC 501.2 – Premises identification. New and existing buildings shall have approved numbers or letters. Each character shall not be less than 3 inches high with a minimum stroke width of 0.5 inch. They should be installed on a contrasting background and be plainly legible and visible from the street or road fronting the property. When required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers and letters shall be Arabic numbers or alphabetical letters. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address numbers shall be maintained. In multi-tenant commercial buildings where tenants have multiple entrances located on different sides of the building, each door shall be addressed. Address characters shall be capable of being illuminated by an internal or external lighting source. Action required: Update records to show correct address which is 314 SW Blue Pkwy.
Bldg - Toilet room wall finish 1210.2.2
Corrective Action Required
07/10/2019

1209.2.2 Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and Actions required: - Specify compliant wall finish materials at mop sink. - Raise tile around water closets to 48" at details on sheets A2 & A4.
Licensed Contractors Rejected 07/10/2019
Joe Frogge
LC - MEP Subs
Resolved
07/17/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 07/15/2019 07/08/2019
Michael Weissenbach
Address numbers required
Corrective Action Required
07/08/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address front and back doors 314
Portable fire extinguishers - conspicuous locations
Corrective Action Required
07/08/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide one 2A10BC Extiguisher
Door operations
Corrective Action Required
07/08/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (Verified At Inspection)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $385.60 $385.60 Paid 07/18/2019
$0.00
8331507-Sewer Connection Fee $60.00 $60.00 Paid 07/18/2019
7232302-Commercial License Tax Fee $3,630.00 $3,630.00 Paid 07/02/2019
$3,630.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Electrical Inspection - Commercial Passed 7/19/2019 at 9:10 AM 07/19/2019
Underslab Plumbing Inspection - Commercial Passed 7/19/2019 at 9:00 AM 07/19/2019
Occupancy Inspection - Fire Partial 7/25/2019 at 9:20 AM 07/25/2019
Misc
Partial Correction
07/25/2019
OK TO COVER NEW AND MODIFIED WALLS AT [101]/[102] EXCEPT AT NW CORNER WHERE PVC PLUMBING PIPE IS NOT PROTECTED PER IPC 305.8. BOCA PLATE REQUIRED. MODIFIED WALL AT DRINKING FOUNTAIN LOCATION NOT APPROVED TO COVER. PVC PLUMBING PIPE IS NOT PROTECTED PER IPC 305.8. SHIELD PLATES & BOCA PLATE REQUIRED.
In-wall Inspection Partial 7/26/2019 7/26/2019 at 7:05 AM 07/26/2019
Misc
Partial Correction
07/25/2019
OK TO COVER NEW AND MODIFIED WALLS AT [101]/[102] EXCEPT AT NW CORNER WHERE PVC PLUMBING PIPE IS NOT PROTECTED PER IPC 305.8. BOCA PLATE REQUIRED.
In-wall Inspection Not Ready 7/29/2019 7/29/2019 at 7:10 AM 07/29/2019
Misc
Partial Correction
07/26/2019
STILL NO BOCA PLATE TO PROTECT PVC PLUMBING PIPE PER IPC 305.8. AT NW CORNER. NOT READY FOR INSPECTION. EXTRA INSPECTION FEE ASSESSED.
In-wall Inspection Passed 7/30/2019 7/30/2019 at 7:00 AM 07/30/2019
Misc
Resolved
07/30/2019
OK TO COVER NEW AND MODIFIED WALLS INCLUDING AT NW CORNER.
Above Ceiling Inspection Failed 8/9/2019 8/9/2019 at 1:20 PM 08/09/2019
Misc
Corrective Action Required
08/09/2019
ELECTRICIANS WORKING ABOVE CEILING. NOT READY FOR INSPECTION.
Above Ceiling Inspection Failed 8/12/2019 8/12/2019 at 1:55 PM 08/12/2019
Misc
Corrective Action Required
08/09/2019
SUPPORT OF FLEXIBLE HVAC DUCT AND CONNECTORS TO STRUCTURE: SUPPORT AT 5' MAXIMUM INTERVALS WITH MIN 1-1/2" WIDE STRAPS, PER SMACNA, AIR DIFFUSION COUNCIL AND MANUFACTURERS INSTRUCTIONS.
Misc
Corrective Action Required
08/12/2019
PIPE PLUMBING FIXTURE VENTS TO VENT STACK
Misc
Corrective Action Required
08/12/2019
OK TO PLACE CEILING BORDER TILES <24"
Above Ceiling Inspection Failed 8/13/2019 8/13/2019 at 9:50 AM 08/13/2019
Misc
Corrective Action Required
08/12/2019
SUPPORT OF FLEXIBLE HVAC DUCT AND CONNECTORS TO STRUCTURE: SUPPORT AT 5' MAXIMUM INTERVALS WITH MIN 1-1/2" WIDE STRAPS, PER SMACNA, AIR DIFFUSION COUNCIL AND MANUFACTURERS INSTRUCTIONS.
Misc
Resolved
08/13/2019
PIPE PLUMBING FIXTURE VENTS TO VENT STACK
Misc
Corrective Action Required
08/12/2019
OK TO PLACE CEILING BORDER TILES <24"
Above Ceiling Inspection Passed 8/19/2019 8/19/2019 08/19/2019
Misc
Resolved
08/19/2019
SUPPORT OF FLEXIBLE HVAC DUCT AND CONNECTORS TO STRUCTURE: SUPPORT AT 5' MAXIMUM INTERVALS WITH MIN 1-1/2" WIDE STRAPS, PER SMACNA, AIR DIFFUSION COUNCIL AND MANUFACTURERS INSTRUCTIONS.
Misc
Resolved
08/19/2019
OK TO PLACE CEILING BORDER TILES <24"
Occupancy Inspection - Fire Passed 8/22/2019 08/22/2019
Misc
Partial Correction
08/22/2019
OK TO COVER NEW AND MODIFIED WALLS AT [101]/[102] EXCEPT AT NW CORNER WHERE PVC PLUMBING PIPE IS NOT PROTECTED PER IPC 305.8. BOCA PLATE REQUIRED. MODIFIED WALL AT DRINKING FOUNTAIN LOCATION NOT APPROVED TO COVER. PVC PLUMBING PIPE IS NOT PROTECTED PER IPC 305.8. SHIELD PLATES & BOCA PLATE REQUIRED.
Occupancy Inspection - Codes Commercial Full C of O 8/22/2019 8/22/2019 at 8:45 AM 08/22/2019
Documents & Images
Date Uploaded File Type Document Name
07/02/2019 Letter License Tax Bill
07/02/2019 RE lt question - prcom20191742
07/08/2019 Letter Fire Building Plan Review
07/10/2019 Letter DS P/R Corrections Document
07/11/2019 Letter Fire Building Plan Review
07/17/2019 Letter Codes Plan Review Conditions
07/18/2019 Receipt Receipt for transaction: 2019-004898
07/18/2019 Letter DS Building Permit
07/19/2019 Letter INSPECTION SUMMARY
07/20/2019 Letter INSPECTION SUMMARY
07/25/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/30/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
08/19/2019 Letter INSPECTION SUMMARY
08/22/2019 Letter Field Certificate of Occupancy
08/26/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home