Summary
PRCOM20191196
Building Permit - Commercial
Certificate of Occupancy
DACUR INVESTMENT COMPANY INC
CHANGE OF TENANT
TENANT FINISH FOR SCRAPBOOKING AND FRAME SHOP
05/09/2019
05/23/2019
11/10/2019
06/19/2019
Locations
Contacts
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
D O G HOMES LLC, Address:1221 W 103RD ST #204, Phone:(816) 508-5007  
A3G , Address:15 SOUTH MAIN ST, Phone:(816) 581-6333  
AUTOMATED CONTROL SYSTEMS CORP, Address:5251 W 116TH PL, STE 200, Phone:(913) 248-8828  
N8'S ELECTRIC LLC, Address:39302 E US 50 HWY, Phone:(816) 809-3110  
MR PLUMBER INC, Address:3057 MERRIAM LANE, Phone:(913) 238-1498  
A3G , Address:15 SOUTH MAIN ST, Phone:(816) 581-6333  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 05/17/2019 05/22/2019
Joe Frogge
LC - MEP Subs
Resolved
05/22/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company name of licensed mechanical contractor. 5/20/19 - ACS does not have a LS business license
Fire Plan Review Approved with Conditions 05/24/2019 05/22/2019
Michael Weissenbach
Address numbers required
Corrective Action Required
05/14/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(verified at inspection) Numeric address of 198 shall be readable from roadway on front and rear doors.
Portable fire extinguishers - conspicuous locations
Corrective Action Required
05/14/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. ACTION REQUIRED:(verified at inspection) Relocate the fire extinguisher from current location shown on plans. Rear door will obstruct access when opened.
Misc
Resolved
05/22/2019

Frame shop ACTION REQUIRED: Provide information about the frame shop. Is the shop going to sell pre assembled frames? Are the frames pre finished? Is there going to be wood cutting and spray finishes involved?
Door operations
Corrective Action Required
05/14/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) No keyed locks on the egress side (interior) of an exit.
Miscellaneous Correction
Resolved
05/22/2019

Room use ACTION REQUIRED: Show on the plans the use of all rooms and ares of the business.
Posting of occupant load
Corrective Action Required
05/22/2019

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Action required) Post occupant load of 49 and maintain existing egresses.
Building Plan Review Approved with Conditions 05/24/2019 05/21/2019
Joe Frogge
Code analysis required
Resolved
05/21/2019

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Update code analysis. - - Recalculate occupant load at 1 person per 30sf 5/20/19 - Given that occupant load now exceeds 50, all doors must swing in direction of egress. Note: mercantile occupant load calculations are not required to be applied to the gross square footage. Each space can be evaluated separately which may reduce occ load enough to comply as is. - 5/21/19 - given the hybrid nature of this space we have agreed to allow a maximum posted occupant load of 49. IEBC says that alteration projects must maintain existing egress capacity which we have.
Plumb - Minimum number of fixtures 403.1
Resolved
05/20/2019

2018 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide drinking fountain or approved alternate.
Miscellaneous Correction
Corrective Action Required
05/14/2019

Inadequate information to complete review. Provide the following: - Mechanical design or detailed scope of work. 5/20/19 - acknowledged in letter, not yet provided - - Label all spaces to designate use 5/20/19 - provided, although with this new information we see that egress is being routed through a storage room which is only allowed if path is clearly allocated and labeled. - -
Building Plan Review Rejected 05/21/2019 05/14/2019
Joe Frogge
Code analysis required
Corrective Action Required
05/14/2019

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Update code analysis. - Application calls this space retail which is M - Recalculate occupant load at 1 person per 30sf - Clarify square feet. 2550 or 1994? Application forms conflict with code analysis.
Plumb - Minimum number of fixtures 403.1
Corrective Action Required
05/14/2019

2018 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide drinking fountain or approved alternate.
Miscellaneous Correction
Corrective Action Required
05/14/2019

Inadequate information to complete review. Provide the following: - Mechanical design or detailed scope of work. - Restroom exhaust fan. - Label all spaces to designate use - Shelving plan - Point of sale cabinetry details (to verify accessibility)
Licensed Contractors Rejected 05/21/2019 05/14/2019
Joe Frogge
LC - MEP Subs
Corrective Action Required
05/14/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company name of licensed mechanical contractor.
Fire Plan Review Rejected 05/21/2019 05/10/2019
Joe Dir
Address numbers required
Corrective Action Required
05/10/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(verified at inspection) Numeric address of 198 shall be readable from roadway on front and rear doors.
Portable fire extinguishers - conspicuous locations
Corrective Action Required
05/10/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. ACTION REQUIRED:(verified at inspection) Relocate the fire extinguisher from current location shown on plans. Rear door will obstruct access when opened.
Misc
Corrective Action Required
05/10/2019

Frame shop ACTION REQUIRED: Provide information about the frame shop. Is the shop going to sell pre assembled frames? Are the frames pre finished? Is there going to be wood cutting and spray finishes involved?
Door operations
Corrective Action Required
05/10/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) No keyed locks on the egress side (interior) of an exit.
Miscellaneous Correction
Corrective Action Required
05/10/2019

Room use ACTION REQUIRED: Show on the plans the use of all rooms and ares of the business.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $108.00 $108.00 Paid 05/23/2019
$4,800.00
8331507-Sewer Connection Fee $60.00 $60.00 Paid 05/23/2019
7232302-Commercial License Tax Fee $4,800.00 $4,800.00 Paid 05/22/2019
$4,800.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 6/3/2019 at 8:05 AM 06/03/2019
Above Ceiling Inspection Failed 6/3/2019 at 8:20 AM 06/03/2019
Misc
Corrective Action Required
06/03/2019
REMOVE ABANDONED CONDUIT SECURE MC CABLE W/I 12" OF BOXES SECURE BOXES TO STRUCTURE CLOSE ALL ACTIVE BOXES
Above Ceiling Inspection Passed 6/4/2019 6/4/2019 at 8:45 AM 06/04/2019
Misc
Resolved
06/04/2019
REMOVE ABANDONED CONDUIT SECURE MC CABLE W/I 12" OF BOXES SECURE BOXES TO STRUCTURE CLOSE ALL ACTIVE BOXES
Miscellaneous Inspection Partial 6/11/2019 06/11/2019
Miscellaneous Inspection Passed 6/18/2019 at 8:50 AM 06/18/2019
Occupancy Inspection - Codes Commercial Full C of O 6/19/2019 6/19/2019 at 10:00 AM 06/19/2019
Occupancy Inspection - Fire Passed 6/19/2019 06/19/2019
Documents & Images
Date Uploaded File Type Document Name
05/09/2019 Letter License Tax Bill
05/10/2019 Letter Fire Building Plan Review
05/14/2019 Letter DS P/R Corrections Document
05/21/2019 City Comments - Letter of Response 21 May 2019
05/22/2019 Letter Fire Building Plan Review
05/22/2019 Letter Codes Plan Review Conditions
05/23/2019 Receipt Receipt for transaction: 2019-002743
05/23/2019 Letter Codes Building Permit
06/03/2019 Letter INSPECTION SUMMARY
06/03/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/19/2019 Letter Field Certificate of Occupancy
06/20/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents