Summary
PRCOM20190858
Building Permit - Commercial
Certificate of Occupancy
PINE TREE PLAZA LLC
CHANGE OF TENANT
CHANGE OF TENANT FOR DELIVERY AND CARRYOUT ONLY PIZZA ** Invite planner to final to verify screening
04/10/2019
06/14/2019
10/09/2019
12/18/2019
Locations
Contacts
PINE TREE PLAZA LLC, Address:601 E SOUTH ST  
LICKEL ARCHITECTURE, Address:14 WEST 3RD ST; SUITE 100, Phone:(816) 421-0707  
ALDEN PLUMBING & MECHANICAL LLC, Address:5600 W 95TH ST STE307, Phone:(816) 666-8662  
BROOKS ELECTRICAL, Address:1107 N 1712 RD, Phone:(785) 838-9040  
RODINA COMPANY INC, Address:1204 N 59TH ST, Phone:(913) 334-5336  
FRANK@LICKELARCHITECTURE.COM  
ADVANCED BUILDING SPECIALTIES INC, Address:213 S MAIN ST, Phone:(601) 582-2745  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 04/26/2019 06/14/2019
Joe Frogge
LC - General Contractor
Resolved
06/14/2019

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor. 4/26/19 - acknowledged
LC - MEP Subs
Resolved
06/14/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 4/26/19 - acknowledged
Fire Plan Review Approved with Conditions 05/03/2019 04/30/2019
Joe Frogge
Address numbers required
Corrective Action Required
04/26/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(Verified at inspection) Numeric address of 350 shall be readable from the roadway (Blue Parkway)
Installation acceptance testing
Corrective Action Required
04/26/2019

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. ACTION REQUIRED:(information purposes) Acceptance testing of the two Type-1 kitchen hood suppression systems is required prior to the final occupancy inspection. Contact the fire department to schedule testing.(816)969-1300
Portable fire extinguishers for commercial cooking equipment.
Resolved
04/29/2019

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. ACTION REQUIRED:(verified at inspection) Two K-class fire extinguishers are required. One for each kitchen hood. First K-class fire extinguisher location: Plan sheet A2, relocate the K-class exitnguisher located on the east kitchen wall by the pizza oven. The new location will be on the south kitchen wall under the two pull stations. Second K-class extinguisher location: Eliminate the B2-001 ABC extinguihser on the east kitchen wall by the R2-009 Beverage cooler, install a second K-class fire extinguisher in its place.
Portable fire extinguishers - general
Resolved
04/29/2019

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED:(verified at inspection) Square footage of the space only requires one 2A-10BC (ABC) fire extinguisher. Plan sheet A2: The B2-001 ABC fire extinguisher located by the rear exit is to remain in that location. Eliminate the B2-001 ABC fire extinguisher located on the east kitchen wall by the R2-009 beverage. cooler.
Door operations
Corrective Action Required
04/26/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) No keyed locks on the egress side (interior) of an exit.
Building Plan Review Approved with Conditions 05/03/2019 04/26/2019
Joe Frogge
Health Dept Inspection
Corrective Action Required
04/26/2019

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes only. 4/26/19 - acknowledged
Plan Submittal 2012 Codes
Resolved
04/26/2019

All plans submitted for review on or after April 1, 2019 shall be designed to the requirements of the 2018 International Building Code, 2018 International Mechanical Code, 2018 International Plumbing Code, 2018 International Fuel Gas Code, 2018 International Fire Code, 2017 National Electric Code and the ANSI A117.1-2017 as amended and adopted by the City of Lee’s Summit. Action required: Update code analysis, General Structural Notes, and Partition Wall Legend
Screening - Rooftop equipment
Corrective Action Required
04/26/2019

Unified Development Ordinance Article 7, Section 7.180.E Roof mounted equipment – All roof-mounted equipment shall be screened entirely from view by using parapet walls at the same height as the mechanical units. For additions to existing buildings that do not meet this standard, individual screens will be permitted, with the design subject to approval by the Director. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened from all 4 sides per referenced UDO section. 4/26/19 - acknowledged - field verify
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Corrective Action Required
04/26/2019

2018 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. ICC A117.1-2017 Section 904.3 Sales and Service Counters. Sales and service counters shall comply with Section 904.3.1 or 904.3.2. The accessible portion of the countertop shall extend the same depth as the sales and service countertop. 904.3.1 Parallel Approach. A portion of the counter surface 36 inches minimum in length and 36 inches maximum in height above the floor shall be provided. Where the counter surface is less than 36 inches in length the entire counter surface shall be 36 inches maximum in height above the floor. A clear floor space complying with Section 305, positioned for a parallel approach adjacent to the accessible counter, shall be provided. Action required: Point of sale counter top to be accessible. To be field verified. 4/26/19 - acknowledged - field verify
Building Plan Review Rejected 04/22/2019 04/12/2019
Joe Frogge
Health Dept Inspection
Corrective Action Required
04/10/2019

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes only.
Plan Submittal 2012 Codes
Corrective Action Required
04/12/2019

All plans submitted for review on or after April 1, 2019 shall be designed to the requirements of the 2018 International Building Code, 2018 International Mechanical Code, 2018 International Plumbing Code, 2018 International Fuel Gas Code, 2018 International Fire Code, 2017 National Electric Code and the ANSI A117.1-2017 as amended and adopted by the City of Lee’s Summit. Action required: Update code analysis, General Structural Notes, and Partition Wall Legend
Screening - Rooftop equipment
Corrective Action Required
04/12/2019

Unified Development Ordinance Article 7, Section 7.180.E Roof mounted equipment – All roof-mounted equipment shall be screened entirely from view by using parapet walls at the same height as the mechanical units. For additions to existing buildings that do not meet this standard, individual screens will be permitted, with the design subject to approval by the Director. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened from all 4 sides per referenced UDO section.
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Corrective Action Required
04/12/2019

2018 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. ICC A117.1-2017 Section 904.3 Sales and Service Counters. Sales and service counters shall comply with Section 904.3.1 or 904.3.2. The accessible portion of the countertop shall extend the same depth as the sales and service countertop. 904.3.1 Parallel Approach. A portion of the counter surface 36 inches minimum in length and 36 inches maximum in height above the floor shall be provided. Where the counter surface is less than 36 inches in length the entire counter surface shall be 36 inches maximum in height above the floor. A clear floor space complying with Section 305, positioned for a parallel approach adjacent to the accessible counter, shall be provided. Action required: Point of sale counter top to be accessible. To be field verified.
Fire Plan Review Approved with Conditions 04/22/2019 04/11/2019
Joe Dir
Address numbers required
Corrective Action Required
04/11/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(Verified at inspection) Numeric address of 350 shall be readable from the roadway (Blue Parkway)
Installation acceptance testing
Corrective Action Required
04/11/2019

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. ACTION REQUIRED:(information purposes) Acceptance testing of the two Type-1 kitchen hood suppression systems is required prior to the final occupancy inspection. Contact the fire department to schedule testing.(816)969-1300
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
04/11/2019

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. ACTION REQUIRED:(verified at inspection) Two K-class fire extinguishers are required. One for each kitchen hood. First K-class fire extinguisher location: Plan sheet A2, relocate the K-class exitnguisher located on the east kitchen wall by the pizza oven. The new location will be on the south kitchen wall under the two pull stations. Second K-class extinguisher location: Eliminate the B2-001 ABC extinguihser on the east kitchen wall by the R2-009 Beverage cooler, install a second K-class fire extinguisher in its place.
Portable fire extinguishers - general
Corrective Action Required
04/11/2019

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED:(verified at inspection) Square footage of the space only requires one 2A-10BC (ABC) fire extinguisher. Plan sheet A2: The B2-001 ABC fire extinguisher located by the rear exit is to remain in that location. Eliminate the B2-001 ABC fire extinguisher located on the east kitchen wall by the R2-009 beverage. cooler.
Door operations
Corrective Action Required
04/11/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) No keyed locks on the egress side (interior) of an exit.
Licensed Contractors Rejected 04/22/2019 04/10/2019
Joe Frogge
LC - General Contractor
Corrective Action Required
04/10/2019

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
04/10/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Health Department Review Approved 04/22/2019 04/10/2019
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $1,046.20 $1,046.20 Paid 06/14/2019
8331507-Sewer Connection Fee $120.00 $120.00 Paid 06/14/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 6/20/2019 6/20/2019 at 8:50 AM 06/20/2019
Misc
Partial Correction
06/20/2019
MAIN BUILDING DRAIN ONLY OK TO COVER WHEN READY.
Underslab Plumbing Inspection - Commercial Partial 6/20/2019 at 3:45 PM 06/20/2019
Misc
Partial Correction
06/20/2019
MAIN BUILDING DRAIN ONLY OK TO COVER WHEN READY.
Underslab Plumbing Inspection - Commercial Passed 6/21/2019 at 8:35 AM 06/21/2019
Misc
Resolved
06/21/2019
MAIN BUILDING DRAIN ONLY OK TO COVER WHEN READY.
In-wall Inspection Failed 6/26/2019 at 9:10 AM 06/26/2019
In-wall Inspection Partial 6/27/2019 6/27/2019 at 9:15 AM 06/27/2019
Misc
Partial Correction
06/27/2019
OK TO COVER WHEN READY LIGHT-GAUGE STEEL WALL FRAMING + IN-WALL SYSTEMS EXCEPT AT SHORT WALL YET TO BE BUILT AT WALK-IN FREEZER AND WEST WALL WHERE ELECTRICAL PANELS ARE LOCATED REMINDER -- NO CEILING TILE IS TO BE PLACED PRIOR TO ABOVE-CEILING INSPECTION AND APPROVAL EXCEPT THOSE FEW WHICH MAY BE NECESSARY FOR INSTALLATION OF ELECTRICAL OR OTHER DEVICES.
In-wall Inspection Partial 7/1/2019 7/1/2019 at 7:10 AM 07/01/2019
Misc
Partial Correction
06/27/2019
OK TO COVER WHEN READY LIGHT-GAUGE STEEL WALL FRAMING + IN-WALL SYSTEMS EXCEPT AT SHORT WALL YET TO BE BUILT AT WALK-IN FREEZER REMINDER -- NO CEILING TILE IS TO BE PLACED PRIOR TO ABOVE-CEILING INSPECTION AND APPROVAL EXCEPT THOSE FEW WHICH MAY BE NECESSARY FOR INSTALLATION OF ELECTRICAL OR OTHER DEVICES.
Gas Piping Inspection - Commercial Failed 7/19/2019 at 9:20 AM 07/19/2019
Misc
Corrective Action Required
07/19/2019
IFGC 408 GAS PIPING DRIP/DIRT LEG: MUST BE AT ELEVATION TO HAVE CAP REMOVED FOR CLEANING AND REPLACED. BOTTOM OF NIPPLE TO BE NO CLOSER TO ROOF THAN DEPTH OF CAP + 1/4".
Misc
Corrective Action Required
07/19/2019
IFGC 404.8: METALLIC PIPING EXPOSED TO WEATHER MUST BE PERMANENTLY PROTECTED WITH PAINT OR BY OTHER APPROVED MEANS. PAINT 100% OF STEEL PIPE INCLUDING AT SUPPORTS. SEE GAS PIPING AT METER AND ROOFTOP.
Gas Service Inspection - Commercial Passed 7/19/2019 7/19/2019 at 9:35 AM 07/19/2019
In-wall Inspection Passed 7/19/2019 7/19/2019 at 9:45 AM 07/19/2019
Misc
Resolved
07/19/2019
OK TO COVER WHEN READY LIGHT-GAUGE STEEL WALL FRAMING + IN-WALL SYSTEMS EXCEPT AT SHORT WALL YET TO BE BUILT AT WALK-IN FREEZER REMINDER -- NO CEILING TILE IS TO BE PLACED PRIOR TO ABOVE-CEILING INSPECTION AND APPROVAL EXCEPT THOSE FEW WHICH MAY BE NECESSARY FOR INSTALLATION OF ELECTRICAL OR OTHER DEVICES.
Above Ceiling Inspection Failed 7/30/2019 7/30/2019 at 7:10 AM 07/30/2019
Misc
Corrective Action Required
07/30/2019
NO READY PRE E.C. & J.B.
Hood/Duct Inspection Not Ready 8/2/2019 8/2/2019 at 1:15 PM 08/02/2019
Hood/Duct Inspection Partial 8/5/2019 8/5/2019 at 10:40 AM 08/05/2019
Misc
Partial Correction
08/05/2019
LIGHT TEST OF GREASE DUCT AT EAST AND WEST HOODS. DUCT WAS INSTALLED WITHOUT LIGHT TEST OF SHOP WELDS. NO HOLES FOUND ON DUCT AT EAST HOOD. AT WEST HOOD UPPER 36" WAS NOT ACCESSIBLE FOR LIGHT TEST. NO HOLES FOUND BELOW THAT ELEVATION.
Misc
Corrective Action Required
08/05/2019
IMC 507.16 COMMERCIAL KITCHEN GREASE HOOD PERFORMANCE TEST: NEBB-CERTIFIED REPORT REQUIRED TO BE SUBMITTED TO INSPECTOR WHEN EQUIPMENT IS OPERATIONAL AND BEFORE COMMERCIAL USE. SMOKE CAPTURE TEST TO BE CERTIFIED BY 3RD PARTY OR WITNESSED BY INSPECTOR BEFORE ANY USE IS APPROVED.
Above Ceiling Inspection Failed 8/7/2019 8/7/2019 at 7:05 AM 08/07/2019
Misc
Corrective Action Required
07/30/2019
REMOVE ALL ABANDONED MATERIAL: FRAMING MEMBERS; HANGERS; ETC
Misc
Corrective Action Required
08/07/2019
RESTORE MISSING OR DISPLACED WALL INSULATION
Misc
Corrective Action Required
08/07/2019
DISCONTINUOUS DUCTS AT NORTH WALL??
Misc
Corrective Action Required
08/07/2019
UNIDENTIFIED COPPER TUBE WITH PARTIAL INSULATION??
Misc
Corrective Action Required
08/07/2019
SECURE MC ELECTRICAL CABLE WITHIN 12" OF ENTRY TO BOXES WHEREVER POSSIBLE
Misc
Corrective Action Required
08/07/2019
1ST LAYER OF GREASE DUCT WRAP WAS COVERED BEFORE INSPECTION.
Hood/Duct Inspection Partial 8/8/2019 at 11:20 AM 08/08/2019
Misc
Partial Correction
08/05/2019
LIGHT TEST OF GREASE DUCT AT EAST AND WEST HOODS. DUCT WAS INSTALLED WITHOUT LIGHT TEST OF SHOP WELDS. NO HOLES FOUND ON DUCT AT EAST HOOD. AT WEST HOOD UPPER 36" WAS NOT ACCESSIBLE FOR LIGHT TEST. NO HOLES FOUND BELOW THAT ELEVATION. GREASE DUCT WRAP 1ST LAYER OK TO APPLY 2ND WRAP BOTH HOODS
Misc
Corrective Action Required
08/05/2019
IMC 507.16 COMMERCIAL KITCHEN GREASE HOOD PERFORMANCE TEST: NEBB-CERTIFIED REPORT REQUIRED TO BE SUBMITTED TO INSPECTOR WHEN EQUIPMENT IS OPERATIONAL AND BEFORE COMMERCIAL USE. SMOKE CAPTURE TEST TO BE CERTIFIED BY 3RD PARTY OR WITNESSED BY INSPECTOR BEFORE ANY USE IS APPROVED.
Above Ceiling Inspection Passed 8/8/2019 8/8/2019 at 11:00 AM 08/08/2019
Misc
Corrective Action Required
08/07/2019
REMOVE ALL ABANDONED MATERIAL: FRAMING MEMBERS; HANGERS; ETC
Misc
Corrective Action Required
08/07/2019
RESTORE MISSING OR DISPLACED WALL INSULATION
Misc
Corrective Action Required
08/07/2019
DISCONTINUOUS DUCTS AT NORTH WALL??
Misc
Corrective Action Required
08/07/2019
UNIDENTIFIED COPPER TUBE WITH PARTIAL INSULATION??
Misc
Corrective Action Required
08/07/2019
SECURE MC ELECTRICAL CABLE WITHIN 12" OF ENTRY TO BOXES WHEREVER POSSIBLE
Misc
Corrective Action Required
08/07/2019
1ST LAYER OF GREASE DUCT WRAP WAS COVERED BEFORE INSPECTION.
Hood/Duct Inspection Partial 8/9/2019 8/9/2019 at 1:00 PM 08/09/2019
Misc
Partial Correction
08/08/2019
LIGHT TEST OF GREASE DUCT AT EAST AND WEST HOODS. DUCT WAS INSTALLED WITHOUT LIGHT TEST OF SHOP WELDS. NO HOLES FOUND ON DUCT AT EAST HOOD. AT WEST HOOD UPPER 36" WAS NOT ACCESSIBLE FOR LIGHT TEST. NO HOLES FOUND BELOW THAT ELEVATION. GREASE DUCT WRAP 1ST LAYER OK TO APPLY 2ND WRAP BOTH HOODS; 2ND WRAP APPROVED AT BOTH HOODS
Misc
Corrective Action Required
08/08/2019
IMC 507.16 COMMERCIAL KITCHEN GREASE HOOD PERFORMANCE TEST: NEBB-CERTIFIED REPORT REQUIRED TO BE SUBMITTED TO INSPECTOR WHEN EQUIPMENT IS OPERATIONAL AND BEFORE COMMERCIAL USE. SMOKE CAPTURE TEST TO BE CERTIFIED BY 3RD PARTY OR WITNESSED BY INSPECTOR BEFORE ANY USE IS APPROVED.
Occupancy Inspection - Codes Commercial Failed 8/14/2019 8/14/2019 at 7:10 AM 08/14/2019
Gas Piping Inspection - Commercial Passed 8/14/2019 at 8:45 AM 08/14/2019
Misc
Resolved
08/14/2019
IFGC 408 GAS PIPING DRIP/DIRT LEG: MUST BE AT ELEVATION TO HAVE CAP REMOVED FOR CLEANING AND REPLACED. BOTTOM OF NIPPLE TO BE NO CLOSER TO ROOF THAN DEPTH OF CAP + 1/4".
Misc
Resolved
08/14/2019
IFGC 404.8: METALLIC PIPING EXPOSED TO WEATHER MUST BE PERMANENTLY PROTECTED WITH PAINT OR BY OTHER APPROVED MEANS. PAINT 100% OF STEEL PIPE INCLUDING AT SUPPORTS. SEE GAS PIPING AT METER AND ROOFTOP.
Occupancy Inspection - Codes Commercial Failed 8/14/2019 at 9:00 AM 08/14/2019
Misc
Corrective Action Required
08/14/2019
OBTAIN PLANNING DIVISION APPROVAL; SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENCY WITH THAT OF OF CENTER. OBTAIN FIRE DEPARTMENT APPROVAL
Misc
Corrective Action Required
08/14/2019
PERMANENT PANEL SCHEDULES REQUIRED
Misc
Corrective Action Required
08/14/2019
WEST ROOFTOP EXHAUST FAN: - NOT LABELED - NOT HINGED - NO GREASE PAN - EXPOSED WIRING
Misc
Corrective Action Required
08/14/2019
RTUs NOT LABELED
Misc
Corrective Action Required
08/14/2019
ROOFTOP ELECT RECEPT REQUIRED WITHIN 25' OF EACH UNIT
Misc
Corrective Action Required
08/14/2019
ELECTRICAL WHIP TO REFRIGERATION UNIT SHAL NOT LIE ON ROOF
Misc
Corrective Action Required
08/14/2019
IFGC 407; 415: PROTECTION OF ROOF MEMBRANE UNDER WOODEN PIPING SUPPORT BLOCKS AT ROOFTOP EQUIPMENT: APPLY SPECIFIED / APPROVED, ROOF-COMPATIBLE SLIP SHEET TO UNDERSIDE OF BLOCKS WITH METAL FASTENERS AT SIDES OF BLOCKS.
Misc
Corrective Action Required
08/14/2019
GREASE HOOD SYSTEM VELOCITY TEST REPORT NOT RECEIVED
Misc
Corrective Action Required
08/14/2019
LS CODE OF ORDINANCES 17-309: DISPLAY OF "NO SMOKING" SIGN(S) REQUIRED AT PUBLIC ENTRY(IES). SHALL BE CONSPICOUS AT EACH PUBLIC POINT OF ENTRY.
Misc
Corrective Action Required
08/14/2019
ROOFTOP CLEAR/CLEAN: REMOVE ALL DEBRIS AND UNUSED MATERIAL FROM ROOFTOP. LEAVE NO METAL ITEMS WHICH COULD DAMAGE ROOF SURFACE OR LOOSE MATERIAL WHICH COULD OBSTRUCT ROOF DRAINAGE.
Occupancy Inspection - Planning Temporary C of O 08/15/2019
Corrective Action Required
08/15/2019
Screening of new roof-top mechanical equipment shall be provided along the north side of the builidng at least equal to the height of the units.
Occupancy Inspection - Codes Commercial Failed 8/15/2019 8/15/2019 at 1:10 PM 08/15/2019
Misc
Corrective Action Required
08/14/2019
OBTAIN PLANNING DIVISION APPROVAL; SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENCY WITH THAT OF OF CENTER. OBTAIN FIRE DEPARTMENT APPROVAL
Misc
Corrective Action Required
08/14/2019
PANEL SCHEDULES ARE UNCLEAR. RE-DO AS DESCRIBED TO FRANK.
Misc
Resolved
08/15/2019
WEST ROOFTOP EXHAUST FAN: - NOT LABELED - NOT HINGED - NO GREASE PAN - EXPOSED WIRING
Misc
Resolved
08/15/2019
RTUs NOT LABELED
Misc
Resolved
08/15/2019
ROOFTOP ELECT RECEPT REQUIRED WITHIN 25' OF EACH UNIT
Misc
Resolved
08/15/2019
ELECTRICAL WHIP TO REFRIGERATION UNIT SHAL NOT LIE ON ROOF
Misc
Resolved
08/15/2019
IFGC 407; 415: PROTECTION OF ROOF MEMBRANE UNDER WOODEN PIPING SUPPORT BLOCKS AT ROOFTOP EQUIPMENT: APPLY SPECIFIED / APPROVED, ROOF-COMPATIBLE SLIP SHEET TO UNDERSIDE OF BLOCKS WITH METAL FASTENERS AT SIDES OF BLOCKS.
Misc
Resolved
08/15/2019
GREASE HOOD SYSTEM VELOCITY TEST REPORT NOT RECEIVED
Misc
Resolved
08/15/2019
LS CODE OF ORDINANCES 17-309: DISPLAY OF "NO SMOKING" SIGN(S) REQUIRED AT PUBLIC ENTRY(IES). SHALL BE CONSPICOUS AT EACH PUBLIC POINT OF ENTRY.
Misc
Resolved
08/15/2019
ROOFTOP CLEAR/CLEAN: REMOVE ALL DEBRIS AND UNUSED MATERIAL FROM ROOFTOP. LEAVE NO METAL ITEMS WHICH COULD DAMAGE ROOF SURFACE OR LOOSE MATERIAL WHICH COULD OBSTRUCT ROOF DRAINAGE.
Misc
Partial Correction
08/15/2019
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. STAFFING, TRAINING, FIXTURING, STOCKING OK. NO PUBLIC/CUSTOMERS/PATIENTS PRIOR TO APPROVAL.
Occupancy Inspection - Fire Failed 8/15/2019 08/15/2019
Occupancy Inspection - Fire Passed 8/16/2019 08/16/2019
Occupancy Inspection - Codes Commercial Partial 8/19/2019 8/19/2019 08/19/2019
Misc
Corrective Action Required
08/15/2019
OBTAIN PLANNING DIVISION APPROVAL SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENCY WITH THAT OF OF CENTER.
Misc
Resolved
08/19/2019
PANEL SCHEDULES ARE UNCLEAR. RE-DO AS DESCRIBED TO FRANK.
Misc
Partial Correction
08/15/2019
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. STAFFING, TRAINING, FIXTURING, STOCKING OK.
Occupancy Inspection - Codes Commercial Temporary C of O 8/20/2019 at 8:15 AM 08/20/2019
Misc
Corrective Action Required
08/19/2019
OBTAIN PLANNING DIVISION APPROVAL SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENT WITH THAT OF OF CENTER. PROVIDE REASONABLE PROPOSED TIMELINE FOR COMPLIANCE ON THIS ISSUE.
Misc
Resolved
08/20/2019
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. STAFFING, TRAINING, FIXTURING, STOCKING OK.
Hood/Duct Inspection Passed 09/05/2019
Misc
Resolved
09/05/2019
LIGHT TEST OF GREASE DUCT AT EAST AND WEST HOODS. DUCT WAS INSTALLED WITHOUT LIGHT TEST OF SHOP WELDS. NO HOLES FOUND ON DUCT AT EAST HOOD. AT WEST HOOD UPPER 36" WAS NOT ACCESSIBLE FOR LIGHT TEST. NO HOLES FOUND BELOW THAT ELEVATION. GREASE DUCT WRAP 1ST LAYER OK TO APPLY 2ND WRAP BOTH HOODS; 2ND WRAP APPROVED AT BOTH HOODS
Misc
Resolved
09/05/2019
IMC 507.16 COMMERCIAL KITCHEN GREASE HOOD PERFORMANCE TEST: NEBB-CERTIFIED REPORT REQUIRED TO BE SUBMITTED TO INSPECTOR WHEN EQUIPMENT IS OPERATIONAL AND BEFORE COMMERCIAL USE. SMOKE CAPTURE TEST TO BE CERTIFIED BY 3RD PARTY OR WITNESSED BY INSPECTOR BEFORE ANY USE IS APPROVED.
Occupancy Inspection - Codes Commercial Temporary C of O 9/16/2019 at 11:05 AM 09/16/2019
Misc
Corrective Action Required
08/20/2019
OBTAIN PLANNING DIVISION APPROVAL SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENT WITH THAT OF OF CENTER. PROVIDE REASONABLE PROPOSED TIMELINE FOR COMPLIANCE ON THIS ISSUE.
Occupancy Inspection - Codes Commercial Temporary C of O 9/30/2019 at 3:40 PM 09/30/2019
Misc
Corrective Action Required
09/16/2019
OBTAIN PLANNING DIVISION APPROVAL SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENT WITH THAT OF OF CENTER. PROVIDE REASONABLE PROPOSED TIMELINE FOR COMPLIANCE ON THIS ISSUE.
Occupancy Inspection - Water Utilities Passed 10/07/2019
Occupancy Inspection - Planning Passed 11/20/2019
Occupancy Inspection - Codes Commercial Full C of O 12/18/2019 at 10:15 AM 12/18/2019
Misc
Resolved
12/18/2019
OBTAIN PLANNING DIVISION APPROVAL SEE CITY REQUIREMENT FOR BUILDING EXTERIOR APPEARANCE CONSISTENT WITH THAT OF OF CENTER. PROVIDE REASONABLE PROPOSED TIMELINE FOR COMPLIANCE ON THIS ISSUE.
Documents & Images
Date Uploaded File Type Document Name
04/10/2019 health dept approval
04/11/2019 Letter Fire Building Plan Review
04/12/2019 Letter DS P/R Corrections Document
04/29/2019 Letter Fire Building Plan Review
06/14/2019 Letter Codes Plan Review Conditions
06/14/2019 Receipt Receipt for transaction: 2019-003720
06/14/2019 Letter Codes Building Permit
06/20/2019 Letter INSPECTION SUMMARY
06/21/2019 Letter INSPECTION SUMMARY
06/27/2019 Letter INSPECTION SUMMARY
07/01/2019 Letter INSPECTION SUMMARY
07/01/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
08/02/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
08/07/2019 Letter INSPECTION SUMMARY
08/08/2019 Letter INSPECTION SUMMARY
08/08/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
08/15/2019 Letter INSPECTION SUMMARY
08/19/2019 Letter INSPECTION SUMMARY
08/20/2019 Letter Codes Temporary Certificate of Occupancy
09/16/2019 Letter Codes Temporary Certificate of Occupancy
09/30/2019 Letter Codes Temporary Certificate of Occupancy
12/18/2019 Letter Field Certificate of Occupancy
12/20/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home