Permit Application Status

PRCOM20190666


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20190666
Building Permit - Commercial
Final Completion
B & D BUSINESS HOLDINGS LLC
NEW OTHER (COMMERCIAL)
MONUMENT SIGN WITH SOME ELECTRICAL
03/22/2019
03/22/2019
11/05/2019
Locations
Contacts
COLEMAN EQUIPMENT, Address:4101 NE LAKEWOOD WAY, Phone:(816) 254-5100  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
B & D BUSINESS HOLDINGS LLC, Address:24000 W 43RD STREET  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 03/22/2019 03/22/2019
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $90.00 $90.00 Paid 03/22/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Failed 4/5/2019 4/5/2019 at 9:40 AM 04/05/2019
Misc
Corrective Action Required
04/05/2019
NEED 16 #6 REBARS PERPENDICULAR TO LENGTH
Piers/Caissons Inspection - Commercial Passed 4/5/2019 at 1:45 PM 04/05/2019
Misc
Informational
04/05/2019
UFER WILL BE AVAILABLE FOR SERVICE GROUNDING
Underground Electrical Inspection - Commercial Passed 5/9/2019 5/9/2019 05/09/2019
Final Inspection - Commercial Passed 11/05/2019
Documents & Images
Date Uploaded File Type Document Name
03/22/2019 Receipt Receipt for transaction: 2019-001017
03/22/2019 Letter Codes Building Permit
03/29/2019 Engineer Report/Study DOC032619-03262019152751
04/05/2019 Letter INSPECTION SUMMARY
04/05/2019 Letter INSPECTION SUMMARY
05/09/2019 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home