Summary
PRCOM20183019
Building Permit - Commercial
Certificate of Occupancy
RMT INVESTMENTS INC
CHANGE OF TENANT
TENANT FINISH FOR RETAIL SALES OF HEALTH PRODUCTS
09/07/2018
09/25/2018
03/16/2019
11/25/2018
Locations
Contacts
MID-AMERICA CONTRACTORS INC, Address:1400 IRON, Phone:(816) 221-4516  
MISSION PLUMBING, HEATING AND COOLING, Address:5725 NIEMAN RD STE C, Phone:(913) 631-6506  
H & S ELECTRIC, Address:4901 ANTIOCH RD, Phone:(913) 206-1486  
BNB DESIGNS ARCHITECTURE AND INTERIORS, Address:108 N NETTLETON AVE, Phone:(913) 422-5762  
RMT INVESTMENTS INC, Address:444 RIVERFRONT PLZ APT 604  
B & H PLUMBING LLC, Address:535 SOUTH WALNUT, Phone:(816) 646-7363  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 09/18/2018 09/24/2018
Development Center
LC - MEP Subs
Resolved
09/24/2018

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 09/25/2018 09/20/2018
Joe Dir
Address numbers required
Corrective Action Required
09/18/2018

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(verified at inspection) Address shall be readable from the roadway
Portable fire extinguishers - general
Corrective Action Required
09/18/2018

2012 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED:(veriifed at inspection) Provide a minimum of one 2A-10BC fire extingisher Fire extinguisher to be mounted on a wall close to an exit.
Building Plan Review Approved with Conditions 09/25/2018 09/19/2018
Joe Frogge
License Tax Application
Corrective Action Required
09/18/2018

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Code analysis required
Resolved
09/19/2018

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide occupant load in code analysis. We can add by hand if directed by architect. (28 by my calc)
Fire Plan Review Approved with Conditions 09/19/2018 09/17/2018
Joe Dir
Address numbers required
Corrective Action Required
09/17/2018

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(verified at inspection) Address shall be readable from the roadway
Portable fire extinguishers - general
Corrective Action Required
09/17/2018

2012 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED:(veriifed at inspection) Provide a minimum of one 2A-10BC fire extingisher Fire extinguisher to be mounted on a wall close to an exit.
Building Plan Review Rejected 09/19/2018 09/10/2018
Joe Frogge
License Tax Application
Corrective Action Required
09/10/2018

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Code analysis required
Corrective Action Required
09/10/2018

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide occupant load in code analysis. We can add by hand if directed by architect. (28 by my calc)
Licensed Contractors Rejected 09/19/2018 09/10/2018
Joe Frogge
LC - MEP Subs
Corrective Action Required
09/10/2018

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $104.00 $104.00 Paid 09/25/2018
8331507-Sewer Connection Fee $60.00 $60.00 Paid 09/25/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 9/28/2018 at 9:00 AM 09/28/2018
Underslab Plumbing Inspection - Commercial Passed 10/9/2018 10/9/2018 at 11:00 AM 10/09/2018
Above Ceiling Inspection Failed 10/22/2018 10/22/2018 at 2:55 PM 10/22/2018
Misc
Corrective Action Required
10/22/2018
UNTERMINATED MC CABLE AND NM CABLE -- DEMO OR ENCLOSE IN LISTED BOXES.
Misc
Corrective Action Required
10/22/2018
ELIMINATE UNNECESSARY LENGTH OF RESTROOM EXHAUST HOSE
Occupancy Inspection - Codes Commercial Temporary C of O 10/22/2018 10/22/2018 at 3:15 PM 10/22/2018
Misc
Corrective Action Required
10/22/2018
HEIGHT OF RESTROOM SINK > 34"
Misc
Corrective Action Required
10/22/2018
IBC 1210.1: SURFACE OF RESTROOM FLOOR MUST BE NON-ABSORBENT
Occupancy Inspection - Fire Passed 10/22/2018 10/22/2018
Occupancy Inspection - Codes Commercial Full C of O 10/25/2018 10/25/2018 10/25/2018
Misc
Resolved
10/25/2018
HEIGHT OF RESTROOM SINK > 34"
Misc
Resolved
10/25/2018
IBC 1210.1: SURFACE OF RESTROOM FLOOR MUST BE NON-ABSORBENT
Documents & Images
Date Uploaded File Type Document Name
09/07/2018 Re Fwd updated drawings 419 ward
09/07/2018 Re Fwd updated drawings 419 ward
09/17/2018 Letter Fire Building Plan Review
09/17/2018 Letter Codes P/R Corrections Document
09/20/2018 Letter Fire Building Plan Review
09/24/2018 Letter Codes Plan Review Conditions
09/25/2018 Receipt Receipt for transaction: 2018-006530
09/25/2018 Letter Codes Building Permit
09/28/2018 Letter Inspection Summary
10/01/2018 Drinking fountain
10/09/2018 Letter Inspection Summary
10/22/2018 Letter Codes Temporary Certificate of Occupancy
10/25/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home