Summary
PRCOM20174048
Building Permit - Commercial
Certificate of Occupancy
TI SUMMIT CREST PLAZA LLC
CHANGE OF TENANT
TENANT FINISH FOR RETAIL PHONE STORE - NO CONSTRUCTION OTHER THAN ELECTRICAL
12/15/2017
12/20/2017
01/30/2018
Locations
Contacts
CRICKET WIRELESS, Address:P O BOX 814545, Phone:(816) 367-0579  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
TI SUMMIT CREST PLAZA LLC, Address:7611 STATE LINE RD STE 301  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 12/29/2017 12/18/2017
Joe Dir
Address numbers required
Corrective Action Required
12/18/2017

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:(veriifed at inspection) Addressing shall be readable from the roadway.
Portable fire extinguishers - general
Corrective Action Required
12/18/2017

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED:(veriifed at inspection) Provide one 2A-10BC fire extinguisher. the fire extinguisher is to be mounted on a normal path of travel cloe to an exit.
Building Plan Review Approved with Conditions 12/29/2017 12/15/2017
Joe Frogge
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Corrective Action Required
12/15/2017

2012 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required: At least 36" of sales counter to be maximum 36" high. To be field verified.
Licensed Contractors Approved 12/15/2017 12/15/2017
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $102.13 $102.13 Paid 12/20/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Fire Passed 12/28/2017 12/28/2017
Occupancy Inspection - Codes Commercial Failed 12/28/2017 12/28/2017 at 2:25 PM 12/28/2017
Misc
Corrective Action Required
12/28/2017
APPARENT OPEN NUETRAL CONNECTION AT FOURPLEX ELECT RECEPTACLE AT POINT-OF-SERVICE COUNTER SOUTH END. BOX AT FOURPLEX ELECT RECEPT AT STORAGE RM NORTH WALL NOT SOLID TO FRAMING + SPACERS REQUIRED BEHIND YOKES FOR SOLID MOUNTING.
Misc
Corrective Action Required
12/28/2017
IBC 1210.1: SURFACE OF RESTROOM FLOOR / WALL SURFACE TO 48" A.F.F WITHIN 24" OF WATER CLOSET OR URINAL AND TO 6" A.F.F. PERIMETER OF ROOM: MUST BE NON-ABSORBENT, SMOOTH. PROVIDED MANUFACTURER'S LITERATURE FOR VERIFICATION.
Misc
Corrective Action Required
12/28/2017
ANSI 603.3 MOUNTING OF MIRRORS AT ACCESSIBLE RESTROOMS: SET BOTTOM OF VIEWING SURFACE <= 40" AFF.
Misc
Corrective Action Required
12/28/2017
IPC 420.3: WATER CLOSET SEAT(S) MUST BE COMMERCIAL TYPE WITH OPEN FRONT.
Misc
Informational
12/28/2017
GRAB BARS IN RESTROOM SAID TO HAVE BEEN EXISTING -- INSTALLED BY OTHERS. NON-COMPLIANT. NOT FAILED, BUT SUBJECT TO ADA COMPLAINT IF LEFT AS-IS.
Occupancy Inspection - Codes Commercial Full C of O 1/30/2018 1/30/2018 at 11:30 AM 01/30/2018
Misc
Resolved
01/30/2018
APPARENT OPEN NUETRAL CONNECTION AT FOURPLEX ELECT RECEPTACLE AT POINT-OF-SERVICE COUNTER SOUTH END. BOX AT FOURPLEX ELECT RECEPT AT STORAGE RM NORTH WALL NOT SOLID TO FRAMING + SPACERS REQUIRED BEHIND YOKES FOR SOLID MOUNTING.
Misc
Resolved
01/30/2018
IBC 1210.1: SURFACE OF RESTROOM FLOOR / WALL SURFACE TO 48" A.F.F WITHIN 24" OF WATER CLOSET OR URINAL AND TO 6" A.F.F. PERIMETER OF ROOM: MUST BE NON-ABSORBENT, SMOOTH. PROVIDED MANUFACTURER'S LITERATURE FOR VERIFICATION.
Misc
Resolved
01/30/2018
ANSI 603.3 MOUNTING OF MIRRORS AT ACCESSIBLE RESTROOMS: SET BOTTOM OF VIEWING SURFACE <= 40" AFF.
Misc
Resolved
01/30/2018
IPC 420.3: WATER CLOSET SEAT(S) MUST BE COMMERCIAL TYPE WITH OPEN FRONT.
Misc
Resolved
01/30/2018
GRAB BARS IN RESTROOM SAID TO HAVE BEEN EXISTING -- INSTALLED BY OTHERS. NON-COMPLIANT. NOT FAILED, BUT SUBJECT TO ADA COMPLAINT IF LEFT AS-IS.
Documents & Images
Date Uploaded File Type Document Name
12/18/2017 Letter Fire Building Plan Review
12/18/2017 Letter Codes Plan Review Conditions
12/20/2017 Receipt Receipt for transaction: 2017-007724
12/20/2017 Letter Codes Building Permit
12/28/2017 Letter Inspection Summary
01/30/2018 Letter Field Certificate of Occupancy
01/31/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home