Summary
PRCOM20162403
Building Permit - Commercial
Certificate of Occupancy
LAW OFFICE OF CAMRON HOORFAR PC
CHANGE OF TENANT
TENANT FINISH FOR NEW LAW OFFICE structural repair permit: PRCOM20162474
09/20/2016
01/18/2017
04/03/2017
09/18/2018
Locations
Contacts
NOORY CONSTRUCTION, Address:816 OSAGE AVE, Phone:(913) 709-1642  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
NOORY CONSTRUCTION, Address:816 OSAGE AVE, Phone:(913) 709-1642  
NOORY CONSTRUCTION, Address:816 OSAGE AVE, Phone:(913) 709-1642  
CL ARCHITECTURE (CRAIG LUEBBERT), Address:396 SW WINTERGARDEN, Phone:(816) 536-3472  
LAW OFFICE OF CAMRON HOORFAR PC, Address:415 SW JEFFERSON ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 10/10/2016 04/20/2017
Joe Dir
Address numbers required
Corrective Action Required
04/20/2017

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 415 ON THE BUILDING IN A CONTRASTING COLOR TO THE BACKGROUND READABLE FROM THE ROADWAY (JEFFERSON ST.) (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
04/20/2017

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER FOR EACH LEVEL OF THE BUILDING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
04/20/2017

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS ON A NORMAL PATH OF TRAVEL WITH THE TOP OF THE EXTINGUISHER NO HIGHER THAN 60" OFF FINISH FLOOR. (VERIFIED AT INSPECTION)
Licensed Contractors Approved 10/03/2016 01/18/2017
Development Center
LC - General Contractor
Corrective Action Required
10/03/2016

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
10/03/2016

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Final Development Plan Review Approved 09/30/2016 12/02/2016
Joe Frogge
Fire Plan Review Approved with Conditions 10/10/2016 11/07/2016
Joe Dir
Address numbers required
Corrective Action Required
11/07/2016

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 415 ON THE BUILDING IN A CONTRASTING COLOR TO THE BACKGROUND READABLE FROM THE ROADWAY (JEFFERSON ST.) (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
11/07/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER FOR EACH LEVEL OF THE BUILDING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
11/07/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS ON A NORMAL PATH OF TRAVEL WITH THE TOP OF THE EXTINGUISHER NO HIGHER THAN 60" OFF FINISH FLOOR. (VERIFIED AT INSPECTION)
Building Plan Review Approved with Conditions 10/10/2016 11/02/2016
Joe Frogge
License Tax Application
Corrective Action Required
10/03/2016

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Final Development Plan
Resolved
12/02/2016

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes.
Misc
Resolved
11/02/2016

Unified Development Ordinance Article 7, Section 7.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened per referenced UDO section. 10/4/16 - wood is not an approvable material
Plan Submittal 2012 Codes
Resolved
10/04/2016

All plans submitted for review on or after January 1, 2014 shall be designed to the requirements of the 2012 International Building Code, 2012 International Mechanical Code, 2012 International Plumbing Code, 2012 International Fuel Gas Code, 2012 International Fire Code, 2011 National Electric Code and the ANSI A117.1-2009 as amended and adopted by the City of Lee’s Summit. Action required: Plans have been reviewed and will be inspected per the 2009 ICC/ANSI. (2003 cited on cover)
NEC - Receptacles - Other than dwelling units 210.8(B)
Resolved
10/04/2016

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel.(1) Bathrooms(2) Kitchens(3) Rooftops(4) Outdoors(5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink.(6) Indoor wet locations(7) Locker rooms with associated showering facilities(8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used.(refer to code for exceptions) Action required: Receptacles in basement to be GFCI protected. (masonry in contact with earth is considered a "wet location.")
Misc
Resolved
11/02/2016

Structural sheet S1 has been omitted from one of the submitted sets. Action required: Provide additional copy of sheet S1 complete with engineers signature and seal.
Fire Plan Review Approved with Conditions 10/10/2016 10/05/2016
Joe Dir
10/05/2016

Address numbers required
Corrective Action Required
10/03/2016

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 415 ON THE BUILDING IN A CONTRASTING COLOR TO THE BACKGROUND READABLE FROM THE ROADWAY (JEFFERSON ST.) (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
10/03/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER FOR EACH LEVEL OF THE BUILDING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
10/03/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS ON A NORMAL PATH OF TRAVEL WITH THE TOP OF THE EXTINGUISHER NO HIGHER THAN 60" OFF FINISH FLOOR. (VERIFIED AT INSPECTION)
Fire Plan Review Rejected 09/30/2016 09/22/2016
Joe Dir
Misc
Corrective Action Required
09/22/2016

Have all development plans approved before going forward with the project.
Address numbers required
Corrective Action Required
09/22/2016

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 415 ON THE BUILDING IN A CONTRASTING COLOR TO THE BACKGROUND READABLE FROM THE ROADWAY (JEFFERSON ST.) (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
09/22/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER FOR EACH LEVEL OF THE BUILDING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
09/22/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS ON A NORMAL PATH OF TRAVEL WITH THE TOP OF THE EXTINGUISHER NO HIGHER THAN 60" OFF FINISH FLOOR. (VERIFIED AT INSPECTION)
Building Plan Review Rejected 09/30/2016 09/21/2016
Joe Frogge
License Tax Application
Corrective Action Required
09/21/2016

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Final Development Plan
Corrective Action Required
09/21/2016

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes.
Misc
Corrective Action Required
09/21/2016

Unified Development Ordinance Article 7, Section 7.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened per referenced UDO section.
Plan Submittal 2012 Codes
Corrective Action Required
09/21/2016

All plans submitted for review on or after January 1, 2014 shall be designed to the requirements of the 2012 International Building Code, 2012 International Mechanical Code, 2012 International Plumbing Code, 2012 International Fuel Gas Code, 2012 International Fire Code, 2011 National Electric Code and the ANSI A117.1-2009 as amended and adopted by the City of Lee’s Summit. Action required: Plans have been reviewed and will be inspected per the 2009 ICC/ANSI. (2003 cited on cover)
NEC - Receptacles - Other than dwelling units 210.8(B)
Corrective Action Required
09/21/2016

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel.(1) Bathrooms(2) Kitchens(3) Rooftops(4) Outdoors(5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink.(6) Indoor wet locations(7) Locker rooms with associated showering facilities(8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used.(refer to code for exceptions) Action required: Receptacles in basement to be GFCI protected. (masonry in contact with earth is considered a "wet location.")
Licensed Contractors Rejected 09/30/2016 09/21/2016
Joe Frogge
LC - General Contractor
Corrective Action Required
09/21/2016

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
09/21/2016

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $183.83 $183.83 Paid 01/18/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Not Ready 3/29/2017 3/29/2017 03/29/2017
Misc
Corrective Action Required
03/29/2017
LSCO SEC 7-142; IBC 106: PERMIT DRAWING FOR REVISED UNDER-SLAB PLUMBING NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT PRINTS
Underslab Plumbing Inspection - Commercial Not Ready 4/24/2017 4/24/2017 04/24/2017
Misc
Corrective Action Required
03/29/2017
LSCO SEC 7-142; IBC 106: PERMIT DRAWING FOR REVISED UNDER-SLAB PLUMBING NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT PRINTS
Misc
Corrective Action Required
04/24/2017
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
All Rough Inspection - Commercial Partial 4/25/2017 04/25/2017
Misc
Corrective Action Required
04/25/2017
ROOF SHEATHING TO BE CUT TO FULL OPENING OF ROOF VENTS
Misc
Corrective Action Required
04/25/2017
NEC 250.148; IRC 3808.13 CONTINUITY OF BRANCH WIRING EQUIPMENT GROUNDING CONDUCTORS: WHEREVER >= 2 CABLES IN BOXES USE LISTED WIRE NUTS OR CRIMP CONNECTORS TO CREATE CONTINUITY. TWISTING ONLY OF GROUND CONDUCTORS IS NOT COMPLIANT CONNECTION.
Underslab Plumbing Inspection - Commercial Passed 4/25/2017 4/25/2017 04/25/2017
Misc
Resolved
04/25/2017
LSCO SEC 7-142; IBC 106: PERMIT DRAWING FOR REVISED UNDER-SLAB PLUMBING NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT PRINTS
Misc
Resolved
04/25/2017
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
All Rough Inspection - Commercial Failed 5/2/2017 5/2/2017 05/02/2017
Misc
Resolved
05/02/2017
ROOF SHEATHING TO BE CUT TO FULL OPENING OF ROOF VENTS
Misc
Resolved
05/02/2017
NEC 250.148; IRC 3808.13 CONTINUITY OF BRANCH WIRING EQUIPMENT GROUNDING CONDUCTORS: WHEREVER >= 2 CABLES IN BOXES USE LISTED WIRE NUTS OR CRIMP CONNECTORS TO CREATE CONTINUITY. TWISTING ONLY OF GROUND CONDUCTORS IS NOT COMPLIANT CONNECTION.
Misc
Corrective Action Required
05/02/2017
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
All Rough Inspection - Commercial Passed 5/4/2017 5/4/2017 05/04/2017
Misc
Resolved
05/04/2017
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Rough Electrical Inspection - Commercial Partial 5/17/2017 5/17/2017 05/17/2017
Misc
Partial Correction
05/17/2017
ELECTRICAL EQUIPMENT GROUNDS FOUND TIED THROUGH AT 1ST FLOOR BOXES. DRYWALL GAPS AROUND BOXES HAVE BEEN MUDDED FULL.
Rough Electrical Inspection - Commercial Passed 5/17/2017 10/18/2017
Misc
Resolved
10/18/2017
ELECTRICAL EQUIPMENT GROUNDS FOUND TIED THROUGH AT 1ST FLOOR BOXES. DRYWALL GAPS AROUND BOXES HAVE BEEN MUDDED FULL.
Occupancy Inspection - Water Utilities Passed 11/15/2017
Rough Electrical Inspection - Commercial Passed 11/27/2017 11/27/2017
Misc
Resolved
11/27/2017
ELECTRICAL EQUIPMENT GROUNDS FOUND TIED THROUGH AT 1ST FLOOR BOXES. DRYWALL GAPS AROUND BOXES HAVE BEEN MUDDED FULL.
Occupancy Inspection - Fire Temporary C of O 11/30/2017 11/30/2017
Occupancy Inspection - Codes Commercial Failed 11/30/2017 11/30/2017 at 2:00 PM 11/30/2017
Misc
Corrective Action Required
11/30/2017
ELECT RECEPT AT PANEL MUST BE GFCI PROTECTED
Misc
Corrective Action Required
11/30/2017
ELECT RECEPT AT BREAK VANITY MUST BE GFCI
Misc
Corrective Action Required
11/30/2017
LABEL ALL BREAKERS AT PANEL
Misc
Corrective Action Required
11/30/2017
WATER CLOSET SEAT NOT COMMERCIAL OPEN FRONT TYPE
Misc
Corrective Action Required
11/30/2017
RESTROOM SINK HIGHER THAN 34" MAXIMUM HEIGHT
Misc
Corrective Action Required
11/30/2017
RESOLVE FIRE DEPT ISSUES
Misc
Corrective Action Required
11/30/2017
RESOLVE CIVIL SITE ISSUES
Misc
Corrective Action Required
11/30/2017
RESOLVE PLANNING ISSUES
Sidewalk Inspection Passed 12/01/2017
Driveway Inspection Partial 12/01/2017
Informational
12/01/2017
Contractor needs to grind down the lip at the alley driveway and sidewalk. Will report back when it is done.
Occupancy Inspection - Engineering Not Ready 12/01/2017
Informational
12/01/2017
A punch list has been generated in permit # PRPWFC20162840 for this site. Waiting till those items are fixed.
Occupancy Inspection - Planning Temporary C of O 12/01/2017
Corrective Action Required
12/01/2017
The bare dirt around the parking lot shall be sodded per the approved landscape plan.
Corrective Action Required
12/01/2017
10 trees are required to be planted on the site per the approved landscape plan.
Occupancy Inspection - Codes Commercial Not Ready 12/5/2017 12/5/2017 at 10:15 AM 12/05/2017
Misc
Corrective Action Required
11/30/2017
ELECT RECEPT AT PANEL MUST BE GFCI PROTECTED
Misc
Corrective Action Required
11/30/2017
ELECT RECEPT AT BREAK VANITY MUST BE GFCI
Misc
Corrective Action Required
11/30/2017
LABEL ALL BREAKERS AT PANEL
Misc
Corrective Action Required
11/30/2017
WATER CLOSET SEAT NOT COMMERCIAL OPEN FRONT TYPE
Misc
Corrective Action Required
11/30/2017
RESTROOM SINK HIGHER THAN 34" MAXIMUM HEIGHT
Misc
Corrective Action Required
11/30/2017
RESOLVE FIRE DEPT ISSUES
Misc
Corrective Action Required
11/30/2017
RESOLVE CIVIL SITE ISSUES
Misc
Corrective Action Required
11/30/2017
RESOLVE PLANNING ISSUES
Misc
Corrective Action Required
12/05/2017
PROVIDED LOCK BOX CODE DOES NOT WORK
Occupancy Inspection - Codes Commercial Partial 12/6/2017 at 10:45 AM 12/06/2017
Misc
Resolved
12/06/2017
ELECT RECEPT AT PANEL MUST BE GFCI PROTECTED
Misc
Resolved
12/06/2017
ELECT RECEPT AT BREAK VANITY MUST BE GFCI
Misc
Resolved
12/06/2017
LABEL ALL BREAKERS AT PANEL
Misc
Resolved
12/06/2017
WATER CLOSET SEAT NOT COMMERCIAL OPEN FRONT TYPE
Misc
Resolved
12/06/2017
RESTROOM SINK HIGHER THAN 34" MAXIMUM HEIGHT
Misc
Corrective Action Required
12/06/2017
RESOLVE FIRE DEPT ISSUES
Misc
Corrective Action Required
12/05/2017
RESOLVE CIVIL SITE ISSUES
Misc
Corrective Action Required
12/05/2017
RESOLVE PLANNING ISSUES
Misc
Resolved
12/06/2017
PROVIDED LOCK BOX CODE DOES NOT WORK
Occupancy Inspection - Fire Passed 12/6/2017 12/06/2017
Occupancy Inspection - Engineering Temporary C of O 4/10/2018 at 2:15 PM 04/10/2018
Corrective Action Required
04/10/2018
Jeremy Young 04/10/2018 2:21 PM The only item on the punch list is vegetation. The property needs at least 70% coverage over 90% of the affected area.
Occupancy Inspection - Planning Temporary C of O 4/10/2018 04/11/2018
Corrective Action Required
04/11/2018
LANDSCAPING. - The site is short 8 shrubs per the landscape plan. - The site has no trees planted. A minimum 10 trees are required per the approved plan.
Occupancy Inspection - Codes Commercial Failed 4/9/2018 4/11/2018 at 8:35 AM 04/11/2018
Misc
Resolved
04/06/2018
RESOLVE FIRE DEPT ISSUES
Misc
Corrective Action Required
05/08/2018
RESOLVE CIVIL SITE ISSUES
Misc
Corrective Action Required
12/06/2017
RESOLVE PLANNING ISSUES
Occupancy Inspection - Planning Temporary C of O 05/08/2018
Corrective Action Required
05/08/2018
LANDSCAPING. - The site is short 8 shrubs per the landscape plan. - The site has no trees planted. A minimum 10 trees are required per the approved plan. - The shrubs previously planted to screen the ground-mounted condenser have died. Remove and replace this required landscape screening.
Occupancy Inspection - Planning Failed 5/8/2018 05/08/2018
Miscellaneous Correction
Corrective Action Required
05/08/2018
LANDSCAPING. - The site is short 8 shrubs per the landscape plan. - The site has no trees planted. A minimum 10 trees are required per the approved plan. - The shrubs previously planted to screen the ground-mounted condenser have died. Remove and replace this required landscape screening.
Occupancy Inspection - Codes Commercial Failed 5/7/2018 5/7/2018 05/08/2018
Misc
Resolved
05/08/2018
RESOLVE CIVIL SITE ISSUES
Misc
Corrective Action Required
04/11/2018
RESOLVE PLANNING ISSUES
Occupancy Inspection - Codes Commercial Partial 9/18/2018 9/18/2018 at 10:15 AM 09/18/2018
Misc
Corrective Action Required
05/08/2018
RESOLVE PLANNING ISSUES
Occupancy Inspection - Planning Passed 09/18/2018
Miscellaneous Correction
Corrective Action Required
05/08/2018
LANDSCAPING. - The site is short 8 shrubs per the landscape plan. - The site has no trees planted. A minimum 10 trees are required per the approved plan. - The shrubs previously planted to screen the ground-mounted condenser have died. Remove and replace this required landscape screening.
Occupancy Inspection - Codes Commercial Full C of O 9/18/2018 09/18/2018
Misc
Resolved
09/18/2018
RESOLVE PLANNING ISSUES
Investigation Inspection Complete 09/20/2018
Documents & Images
Date Uploaded File Type Document Name
09/22/2016 Letter Fire Building Plan Review
09/22/2016 Letter Codes P/R Corrections Document
10/05/2016 Letter Fire Building Plan Review
10/05/2016 Letter Codes P/R Corrections Document
10/05/2016 Letter Codes P/R Corrections Document
11/07/2016 Letter Fire Building Plan Review
01/18/2017 Receipt Receipt for transaction: 2017-000164
01/18/2017 Letter Codes Plan Review Conditions
01/18/2017 Letter Codes Building Permit
04/20/2017 Letter Fire Building Plan Review
04/24/2017 Letter Inspection Summary
04/25/2017 Letter Inspection Summary
05/02/2017 Letter Inspection Summary
05/04/2017 Letter Inspection Summary
05/17/2017 Letter Inspection Summary
10/09/2017 Letter Inspection Summary
11/30/2017 Letter Inspection Summary
12/01/2017 Letter Inspection Summary
12/06/2017 Letter Inspection Summary
04/10/2018 Letter DE-Daily Inspection Summary
04/11/2018 Letter Inspection Summary
05/08/2018 Letter Inspection Summary
09/18/2018 Letter Field Certificate of Occupancy
09/19/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home