Summary
PRCOM20161763
Building Permit - Commercial
Certificate of Occupancy
WBCMT 2006 C27 HIGHWAY 291 RETAIL LLC
CHANGE OF TENANT
CHANGE OF OCCUPANCY FOR NEW PERSONAL TRAINER GYM **plans are in plan review file
07/19/2016
07/26/2016
08/19/2016
Locations
Contacts
A-STRONG STOP LLC, Address:6970 E 47TH TERR, Phone:(417) 291-6652  
WBCMT 2006 C27 HIGHWAY 291 RETAIL LLC, Address:1601 WASHINGTON AVE STE 700  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 07/29/2016 07/25/2016
Joe Dir
Posting of occupant load
Corrective Action Required
07/25/2016

2006 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. POST THE OCCUPANT LOAD
Address numbers required
Corrective Action Required
07/25/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 310 ON THE EXTERIOR OF THE FRONT AND REAR DOORS IN A CONTRASTING COLOR OF THE BACKGROUND. (VERIIFED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
07/25/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE TWO 2A-10BC (5POUND) FIRE EXTINGUISHERS. (VERIFIED AT INSPECTION)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
07/25/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS ON A WALL CLOSE TO FRONT AND REAR EXITS WITH THE TOP OF THE EXTINGUISHER NO HIGHER THAN 60" OFF OF THE FLOOR. (VERIIFED AT INSPECTION)
Building Plan Review Approved 07/29/2016 07/20/2016
Joe Frogge
Licensed Contractors Approved 07/29/2016 07/19/2016
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $30.00 $30.00 Paid 07/26/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Commercial Temporary C of O 7/28/2016 7/28/2016 07/28/2016
Misc
Corrective Action Required
07/28/2016
ELECT RECEPT AT N WALL OF OFFICE NOT SECURED TO BOX. USE BOX EXTENDER DUE TO EXCESSIVE SET-BACK OF BOX.
Misc
Corrective Action Required
07/28/2016
AFFIX "NO SMOKING" STICKER TO PUBLIC ENTRANCE DOOR.
Misc
Corrective Action Required
07/28/2016
RESOLVE FIRE DEPARTMENT ISSUES.
Occupancy Inspection - Fire Temporary C of O 7/28/2016 07/28/2016
Occupancy Inspection - Codes Commercial Failed 8/17/2016 08/17/2016
Misc
Corrective Action Required
07/28/2016
ELECT RECEPT AT N WALL OF OFFICE NOT SECURED TO BOX. USE BOX EXTENDER DUE TO EXCESSIVE SET-BACK OF BOX.
Misc
Corrective Action Required
07/28/2016
AFFIX "NO SMOKING" STICKER TO PUBLIC ENTRANCE DOOR.
Misc
Resolved
08/17/2016
RESOLVE FIRE DEPARTMENT ISSUES.
Occupancy Inspection - Codes Commercial Full C of O 8/19/2016 08/19/2016
Misc
Resolved
08/19/2016
AFFIX "NO SMOKING" STICKER TO PUBLIC ENTRANCE DOOR.
Misc
Resolved
08/19/2016
ELECT RECEPT AT N WALL OF OFFICE NOT SECURED TO BOX. USE BOX EXTENDER DUE TO EXCESSIVE SET-BACK OF BOX.
Documents & Images
Date Uploaded File Type Document Name
07/22/2016 A Strong Indoor Air Quality Check
07/25/2016 Letter Fire Building Plan Review
07/26/2016 Letter Codes Plan Review Conditions
07/26/2016 Letter Codes Building Permit
07/26/2016 Receipt Receipt for transaction: 2016-004979
07/28/2016 Letter Codes Temporary Certificate of Occupancy
08/17/2016 Letter Inspection Summary
08/19/2016 Letter Field Certificate of Occupancy
08/22/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home