Permit Application Status

PRCOM20143454


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20143454
Building Permit - Commercial
Final Completion
NEW RAY LLC
ALTERATION COMMERCIAL
INSTALL VENTLESS FRYER AND RELOCATE PIZZA OVEN
12/24/2014
04/17/2015
07/05/2015
02/04/2016
Locations
Contacts
ARNALDO ELECTRIC LLC, Address:719 KENSINGTON, Phone:(816) 510-0006  
NEW RAY LLC, Address:1317 SW MARKET ST, Phone:(816) 554-1170  
TOTAL HOME SERVICE, Address:3408 N 26TH ST, Phone:(816) 405-6924  
BETTER SERVICE INC, Address:4512 MAIN ENTRANCE DRIVE 3, Phone:(816) 744-4617 Ext:CELL  
MCGRATH HEATING & COOLING LLC, Address:250 S GEOSPACE DR, Phone:(816) 257-7377  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved 04/22/2015 04/17/2015
Joe Frogge
Misc 13
Resolved
04/17/2015

Electrical design. Action required: Provide electrical design or detailed scope of work from licensed electrical contractor. 4/17/15
Misc
Resolved
04/17/2015

2012 IMC 508.1 Makeup air. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied to the building from all sources shall be approximately equal to the amount of exhaust air for all exhaust systems for the building. The makeup air shall not reduce the effectiveness of the exhaust system. Makeup air shall be provided by gravity or mechanical means or both. Mechanical makeup air systems shall be automatically controlled to start and operate simultaneously with the exhaust system. Makeup air intake opening locations shall comply with Section 401.4. 508.1.1 Makeup air temperature. The temperature differential between makeup air and the air in the conditioned space shall not exceed 10degF except where the added heating and cooling loads of the makeup air do not exceed the capacity of the HVAC system. Action required: Provide makeup air system or demonstrate (in the form of a report from a licensed mechanical contractor) that existing HVAC system can support the added exhaust. 4/16/15 - provided
Misc 16
Resolved
04/15/2015

2012 IPC 802.1 Where required. Food-handling equipment and clear-water waste shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. All health-care related fixtures, devices and equipment shall discharge to the drainage system through an indirect waste pipe by means of an air gap in accordance with this chapter and section 713.3. Fixtures not required by this section to be indirectly connected shall be directly connected to the plumbing system in accordance with Chapter 7. Grease Interceptor 2012 IPC 1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the public sewer, the private sewage system or the sewage treatment plant or processes. Action required: At location that grease laden dishes, equipment, etc. are to be cleaned provide an indirect waste into an approved grease intercepting system. 4/15/15 - diagram provided
Fire Plan Review Approved with Conditions 04/22/2015 04/17/2015
Joe Frogge
Misc
Corrective Action Required
04/15/2015

904.11.5 Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving solid fuels or vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher in accordance with Section 904.11.5.1 or 904.11.5.2, as applicable. Action required-Provide a K class extinguisher with appropriate signage near the manual pull station for the fire suppression system. Verified at inspection.
Installation acceptance testing
Corrective Action Required
04/15/2015

IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Call (816) 969-1300 to schedule testing after installation is approved.
Misc
Corrective Action Required
04/15/2015

For information only- 904.11.6.2 Extinguishing system service. Automatic fire-extinguishing systems shall be serviced at least every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion.
Misc
Corrective Action Required
04/15/2015

For information ony- All conditions in the store are subject to inspection folowing relocation and installation of the oven and fryer.
Licensed Contractors Approved 04/15/2015 04/17/2015
Joe Frogge
LC - MEP Subs
Resolved
04/15/2015

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of Mechanical and Electrical contractors.
Health Department Review Approved 01/08/2015 01/06/2015
Joe Frogge
Building Plan Review Rejected 01/08/2015 01/06/2015
Joe Frogge
Misc 16
Corrective Action Required
01/06/2015

2012 IPC 802.1 Where required. Food-handling equipment and clear-water waste shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. All health-care related fixtures, devices and equipment shall discharge to the drainage system through an indirect waste pipe by means of an air gap in accordance with this chapter and section 713.3. Fixtures not required by this section to be indirectly connected shall be directly connected to the plumbing system in accordance with Chapter 7. Grease Interceptor 2012 IPC 1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the public sewer, the private sewage system or the sewage treatment plant or processes. Action required: At location that grease laden dishes, equipment, etc. are to be cleaned provide an indirect waste into an approved grease intercepting system.
Misc
Corrective Action Required
01/06/2015

2012 IMC 508.1 Makeup air. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied to the building from all sources shall be approximately equal to the amount of exhaust air for all exhaust systems for the building. The makeup air shall not reduce the effectiveness of the exhaust system. Makeup air shall be provided by gravity or mechanical means or both. Mechanical makeup air systems shall be automatically controlled to start and operate simultaneously with the exhaust system. Makeup air intake opening locations shall comply with Section 401.4. 508.1.1 Makeup air temperature. The temperature differential between makeup air and the air in the conditioned space shall not exceed 10degF except where the added heating and cooling loads of the makeup air do not exceed the capacity of the HVAC system. Action required: Provide makeup air system or demonstrate (in the form of a report from a licensed mechanical contractor) that existing HVAC system can support the added exhaust.
Misc 13
Corrective Action Required
01/06/2015

Electrical design. Action required: Provide electrical design or detailed scope of work from licensed electrical contractor.
Licensed Contractors Rejected 01/08/2015 01/06/2015
Joe Frogge
LC - MEP Subs
Corrective Action Required
01/06/2015

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of Mechanical and Electrical contractors.
Fire Plan Review Approved with Conditions 01/06/2015 01/02/2015
Jim Eden
Misc
Resolved
01/02/2015

904.11 Commercial cooking systems. The automatic fire-extinguishing system for commercial cooking systems shall be of a type recognized for protection of commercial cooking equipment and exhaust systems of the type and arrangement protected. Preengineered automatic dry- and wet-chemical extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application. Other types of automatic fire-extinguishing systems shall be listed and labeled for specific use as protection for commercial cooking operations. The system shall be installed in accordance with this code, its listing and the manufacturer’s installation instructions. Automatic fire-extinguishing systems of the following types shall be installed in accordance with the referenced standard indicated, as follows: 1. Carbon dioxide extinguishing systems, NFPA 12. 2. Automatic sprinkler systems, NFPA 13. 3. Foam-water sprinkler system or foam-water spray systems, NFPA 16. 4. Dry-chemical extinguishing systems, NFPA 17. 5. Wet-chemical extinguishing systems, NFPA 17A. Exception: Factory-built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed, labeled and installed in accordance with Section 304.1 of the International Mechanical Code. Action required- Provide information on the appliance and fire protection system.
Misc
Corrective Action Required
01/02/2015

904.11.5 Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving solid fuels or vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher in accordance with Section 904.11.5.1 or 904.11.5.2, as applicable. Action required-Provide a K class extinguisher with appropriate signage near the manual pull station for the fire suppression system. Verified at inspection.
Installation acceptance testing
Corrective Action Required
01/02/2015

IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Call (816) 969-1300 to schedule testing after installation is approved.
Misc
Corrective Action Required
01/02/2015

For information only- 904.11.6.2 Extinguishing system service. Automatic fire-extinguishing systems shall be serviced at least every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion.
Misc
Corrective Action Required
01/02/2015

For information ony- All conditions in the store are subject to inspection folowing relocation and installation of the oven and fryer.
Fire Plan Review Rejected 01/08/2015 12/29/2014
Jim Eden
Misc
Corrective Action Required
12/29/2014

904.11 Commercial cooking systems. The automatic fire-extinguishing system for commercial cooking systems shall be of a type recognized for protection of commercial cooking equipment and exhaust systems of the type and arrangement protected. Preengineered automatic dry- and wet-chemical extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application. Other types of automatic fire-extinguishing systems shall be listed and labeled for specific use as protection for commercial cooking operations. The system shall be installed in accordance with this code, its listing and the manufacturer’s installation instructions. Automatic fire-extinguishing systems of the following types shall be installed in accordance with the referenced standard indicated, as follows: 1. Carbon dioxide extinguishing systems, NFPA 12. 2. Automatic sprinkler systems, NFPA 13. 3. Foam-water sprinkler system or foam-water spray systems, NFPA 16. 4. Dry-chemical extinguishing systems, NFPA 17. 5. Wet-chemical extinguishing systems, NFPA 17A. Exception: Factory-built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed, labeled and installed in accordance with Section 304.1 of the International Mechanical Code. Action required- Provide information on the appliance and fire protection system.
Misc
Corrective Action Required
12/29/2014

904.11.5 Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving solid fuels or vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher in accordance with Section 904.11.5.1 or 904.11.5.2, as applicable. Action required-Provide a K class extinguisher with appropriate signage.
Installation acceptance testing
Corrective Action Required
12/29/2014

IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Call (816) 969-1300 to schedule testing after installation is approved.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Alteration to Commercial $30.00 $30.00 Paid 04/17/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Electrical Inspection - Commercial Failed 5/1/2015 5/1/2015 at 12:00 AM 05/01/2015
Misc
Corrective Action Required
05/01/2015
NEED ABOVE CEILING FOR ELECTRICAL AND PLUMBING
Underslab Plumbing Inspection - Commercial Failed 5/1/2015 5/1/2015 at 12:00 AM 05/01/2015
Misc
Corrective Action Required
05/01/2015
VENTING FOR GREASE TRAP NEED CORRECTED- VENT AS PER PLANS AND WALL SINK CON NOT DRAIN INTO "WYE"
Underslab Plumbing Inspection - Commercial Passed 5/5/2015 at 12:00 AM 05/05/2015
Misc
Resolved
05/05/2015
VENTING FOR GREASE TRAP NEED CORRECTED- VENT AS PER PLANS AND WALL SINK CON NOT DRAIN INTO "WYE"
Alternate Protection Systems Inspection Passed 5/8/2015 at 12:00 AM 05/08/2015
Alternate Protection Systems Inspection Passed 5/8/2015 at 12:00 AM 05/13/2015
Occupancy Inspection - Fire Passed 12/31/2015
Hood/Duct Inspection Passed 02/04/2016
Rough Electrical Inspection - Commercial Passed 02/04/2016
Misc
Resolved
02/04/2016
NEED ABOVE CEILING FOR ELECTRICAL AND PLUMBING
Final Inspection - Commercial Passed 02/04/2016
Documents & Images
Date Uploaded File Type Document Name
01/06/2015 Letter Codes P/R Corrections Document
04/17/2015 Letter Codes Plan Review Conditions
04/17/2015 Letter Codes Building Permit
04/17/2015 Receipt Receipt for transaction: 2015-000636
05/01/2015 Letter Inspection Summary
05/05/2015 Letter Inspection Summary
02/04/2016 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home