Summary
PRCOM20132239
Building Permit - Commercial
Final Completion
JEFFREY E SMITH INV CO LC
PARTIAL COMMERCIAL
FOUNDATION, UNDERSLAB AND SLAB ONLY
10/10/2013
11/06/2013
12/01/2014
Locations
Contacts
FAIRWAY CONSTRUCTION CO INC, Address:P O BOX 7688, Phone:(573) 303-3765  
BUILDING CONTROL SOLUTIONS LC, Address:P O BOX 1535, Phone:(816) 439-6046  
WIRE WORKS LLC, Address:5000 W DRISKEL RD  
MAGNUM PLUMBING LLC, Address:19770 STURGEON CEMETARY RD, Phone:(573) 228-3704  
Engineering Surveys & Services, Address:1113 Fay Street  
ROSEMANN & ASSOCIATES, PC, Address:1526 GRAND BLVD  
JEFFREY E SMITH INV CO LC, Address:PO BOX 7688  
ROSEMANN & ASSOCIATES, PC, Address:1526 GRAND BLVD  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 11/08/2013 11/04/2013
Codes Admin
Special Inspections Review Approved 11/08/2013 10/28/2013
Mike Weisenborn
Building Plan Review Approved 10/22/2013 10/17/2013
Mike Weisenborn
Misc
Informational
10/17/2013

This permit is for the foundation, underslab work and slab only. No other work shall be performed under this permit. Action required - This comment is for information purposes.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Partial Commercial $89.49 $89.49 Paid 11/06/2013
$89.49
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Retaining Wall Inspection Partial 11/15/2013 11/15/2013 at 12:00 AM 11/15/2013
Misc
Corrective Action Required
11/15/2013
-EAST RETAINING WALL: BASE COURSE OK
Retaining Wall Inspection Partial 12/3/2013 at 12:00 AM 11/19/2013
Misc
Corrective Action Required
11/15/2013
-EAST RETAINING WALL: BASE COURSE OK, GEO-GRID PLACEMENT OK AS PROGRESS
Retaining Wall Inspection Partial 11/26/2013 11/26/2013 at 12:00 AM 11/26/2013
Misc
Corrective Action Required
11/19/2013
-EAST RETAINING WALL: BASE COURSE OK, GEO-GRID PLACEMENT OK AS PROGRESS
Footing Inspection - Commercial Partial 11/27/2013 (11:00) 12/2/2013 at 12:00 AM 12/02/2013
Misc
Partial Correction
12/02/2013
-FOOTING OK AS PROGRESSED
Footing Inspection - Commercial Partial 12/3/2013 at 12:00 AM 12/03/2013
Misc
Partial Correction
12/02/2013
-FOOTING OK AS PROGRESSED: CCW FROM NE CORNER TO SE CORNER
Footing Inspection - Commercial Not Ready 12/16/2013 (9:00) 12/16/2013 at 12:00 AM 12/16/2013
Misc
Partial Correction
12/03/2013
-FOOTING OK AS PROGRESSED: EXTERIOR GRADE BEAM COMPLETED, EXCEPT AT THE SE CORNER
Misc
Corrective Action Required
12/16/2013
"READY AT 9:30" NOT READY AT 9:50. NO PERMIT PRINTS ON SITE.
Footing Inspection - Commercial Partial 12/16/2013 (3:00) 12/16/2013 at 12:00 AM 12/16/2013
Misc
Partial Correction
12/16/2013
-FOOTING OK AS PROGRESSED: EXTERIOR GRADE BEAM COMPLETED, EXCEPT AT THE SE CORNER
Misc
Resolved
12/16/2013
"READY AT 9:30" NOT READY AT 9:50. NO PERMIT PRINTS ON SITE.
Misc
Corrective Action Required
12/16/2013
OK TO POUR WHEN READY ISOLATED FOOTINGS AT FOLLOWING LOCATIONS: ALL AT LOBBY AREA EXCLUDING THOSE INTEGRAL WITH EXTERIOR WALL AND ELEVATOR PIT SLAB; 3x3 SHEAR WALL HOLD-DOWN FOOTINGS AT N-S AND E-W WINGS;
Footing Inspection - Commercial Not Ready 12/18/2013 (10:00) 12/18/2013 at 12:00 AM 12/18/2013
Misc
Partial Correction
12/16/2013
-FOOTING OK AS PROGRESSED: EXTERIOR GRADE BEAM COMPLETED, EXCEPT AT THE SE CORNER
Misc
Partial Correction
12/18/2013
OK TO POUR WHEN READY ISOLATED FOOTINGS AT FOLLOWING LOCATIONS: ALL AT LOBBY AREA EXCLUDING THOSE INTEGRAL WITH EXTERIOR WALL AND ELEVATOR PIT SLAB; 3x3 SHEAR WALL HOLD-DOWN FOOTINGS AT N-S AND E-W WINGS;
Misc
Partial Correction
12/18/2013
NOT READY AS OF 10:35
Foundation Inspection - Commercial Partial 12/18/2013 at 12:00 AM 12/18/2013
Misc
Partial Correction
12/18/2013
-FOOTING OK AS PROGRESSED: EXTERIOR GRADE BEAM COMPLETED, EXCEPT AT THE SE CORNER
Misc
Partial Correction
12/18/2013
OK TO POUR WHEN READY ISOLATED FOOTINGS AT FOLLOWING LOCATIONS: ALL AT LOBBY AREA EXCLUDING THOSE INTEGRAL WITH EXTERIOR WALL AND ELEVATOR PIT SLAB; 3x3 SHEAR WALL HOLD-DOWN FOOTINGS AT N-S AND E-W WINGS;
Misc
Resolved
12/18/2013
NOT READY AS OF 10:35
Misc
Partial Correction
12/18/2013
ELEVATOR PIT SLAB OK TO POUR WHEN READY
Foundation Inspection - Commercial Partial 12/18/2013 at 12:00 AM 12/18/2013
Misc
Partial Correction
12/18/2013
ELEVATOR PIT SLAB OK TO POUR WHEN READY
Footing Inspection - Commercial Partial 12/19/2013 (2:00) 12/19/2013 at 12:00 AM 12/19/2013
Misc
Partial Correction
12/18/2013
EXTERIOR GRADE BEAM + INTEGRAL COLUMN FOOTINGS OK TO POUR WHEN READY NOW INCLUDING SE CORNER FROM (A) TO (B) MARKED ON PERMIT PRINT SET.
Misc
Resolved
12/19/2013
OK TO POUR WHEN READY ISOLATED FOOTINGS AT FOLLOWING LOCATIONS: ALL AT LOBBY AREA EXCLUDING THOSE INTEGRAL WITH EXTERIOR WALL AND ELEVATOR PIT SLAB; 3x3 SHEAR WALL HOLD-DOWN FOOTINGS AT N-S AND E-W WINGS;
Misc
Resolved
12/19/2013
NOT READY AS OF 10:35
Foundation Inspection - Commercial Partial 12/27/2013 (8:00) 12/27/2013 at 12:00 AM 12/27/2013
Misc
Partial Correction
12/18/2013
OK BELOW: ELEVATOR PIT SLAB, PIT FOUNDATION WALL AND 16" PILASTER
Underslab Plumbing Inspection - Commercial Not Ready 1/22/2014 1/22/2014 at 12:00 AM 01/22/2014
Misc
Corrective Action Required
01/22/2014
SOUTH BUILDING DRAIN OF UNIT A&B: -CANNOT HAVE WASTE STACK TO WET-VENT SHOWER OR WATER CLOSETS -VERTICAL TO HORIZONTAL CONNECTION MUST BE BY LONG SWEEP OR OTHER APPROVED FITTING FOR 3" OR LARGER -HAVE PLUMBING REDRAWN FOR CHANGES TO SEWER LOCATION
Underslab Plumbing Inspection - Commercial Partial 2/19/2014 2/19/2014 at 12:00 AM 02/19/2014
Misc
Partial Correction
02/19/2014
SOUTH BUILDING DRAIN OF UNIT A&B: -UNDERSLAB PLUMBING APPROVED FROM ELEVATOR SHAFT TO THE WEST SIDE -HAVE PLUMBING REDRAWN FOR CHANGES TO SEWER LOCATION
Underslab Electrical Inspection - Commercial Partial 2/19/2014 2/19/2014 at 12:00 AM 02/19/2014
Misc
Partial Correction
02/19/2014
-UNDERSLAB ELECTRICAL APPROVED FROM ELEVATOR TO THE WEST
Underslab Plumbing Inspection - Commercial Passed 3/11/2014 3/11/2014 at 12:00 AM 03/11/2014
Misc
Resolved
03/11/2014
SOUTH BUILDING DRAIN OF UNIT A&B: -UNDERSLAB PLUMBING APPROVED FROM ELEVATOR SHAFT TO THE WEST SIDE -HAVE PLUMBING REDRAWN FOR CHANGES TO SEWER LOCATION
Underslab Electrical Inspection - Commercial Partial 3/14/2014 3/14/2014 at 12:00 AM 03/14/2014
Misc
Partial Correction
02/19/2014
-UNDERSLAB ELECTRICAL APPROVED FROM ELEVATOR TO THE WEST -FROM NORTH OF BUILDING TO CONTROL JOINT
Underslab Electrical Inspection - Commercial Partial 3/17/2014 3/17/2014 at 12:00 AM 03/17/2014
Misc
Partial Correction
03/14/2014
-UNDERSLAB ELECTRICAL APPROVED FROM ELEVATOR TO THE WEST -FROM NORTH OF BUILDING TO CONTROL JOINT
Underslab Electrical Inspection - Commercial Passed 3/18/2014 3/18/2014 at 12:00 AM 03/18/2014
Misc
Resolved
03/18/2014
-UNDERSLAB ELECTRICAL APPROVED FROM ELEVATOR TO THE WEST -FROM NORTH OF BUILDING TO CONTROL JOINT
Retaining Wall Inspection Passed 12/01/2014
Misc
Resolved
12/01/2014
-EAST RETAINING WALL: BASE COURSE OK, GEO-GRID PLACEMENT OK AS PROGRESS
Foundation Inspection - Commercial Passed 12/01/2014
Misc
Resolved
12/01/2014
OK BELOW: ELEVATOR PIT SLAB, PIT FOUNDATION WALL AND 16" PILASTER
Footing Inspection - Commercial Passed 12/01/2014
Misc
Resolved
12/01/2014
EXTERIOR GRADE BEAM + INTEGRAL COLUMN FOOTINGS OK TO POUR WHEN READY NOW INCLUDING SE CORNER FROM (A) TO (B) MARKED ON PERMIT PRINT SET.
Documents & Images
Date Uploaded File Type Document Name
11/04/2013 Letter Codes Plan Review Conditions
11/06/2013 Letter Codes Building Permit
11/15/2013 Letter Inspection Summary
11/26/2013 Letter Inspection Summary
12/03/2013 Letter Inspection Summary
12/16/2013 Letter Inspection Summary
12/16/2013 Letter Inspection Summary
12/18/2013 Letter Inspection Summary
12/19/2013 Letter Inspection Summary
12/27/2013 Letter Inspection Summary
01/22/2014 Letter Inspection Summary
02/19/2014 Letter Inspection Summary
03/11/2014 Letter Inspection Summary
03/14/2014 Letter Inspection Summary
03/17/2014 Letter Inspection Summary
03/18/2014 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home