Summary
PRCOM20131937
Building Permit - Commercial
Certificate of Occupancy
DACUR INVESTMENT COMPANY INC
NEW TENANT FINISH
TENANT FINISH FOR NEW URGENT CARE FACILITY TREATING ILLNESS, LACERATIONS, BROKEN BONES ETC.
09/04/2013
12/03/2013
03/09/2014
05/09/2014
Locations
Contacts
TEAGUE CONSTRUCTION INC, Address:4220 MAIN ST, Phone:(816) 763-1455  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
WESTCO ELECTRIC LLC, Address:PO BOX 93, Phone:(816) 343-8779  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 03/09/2014 12/02/2013
Mike Weisenborn
Business License
Corrective Action Required
09/09/2013

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Provide the name of the licensed general contractor. Either a Class A or B license is required. This information is required for permit approval.
License contractors
Corrective Action Required
09/09/2013

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - Provide the name of the licensed mechanical, electrical and plumbing contractors. This information is required for permit approval.
Building Plan Review Approved 09/23/2013 09/18/2013
Mike Weisenborn
Plumb - Separate facilities
Resolved
09/18/2013

2006 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (See code for possible exceptions.) Action required - Please label one of the restrooms as men's and one as women's. Mike Weisenborn 09/18/2013 2:55 PM - Corrections have been made.
Bldg - Exit signage - Where required
Resolved
09/18/2013

2006 IBC 1011.1 - Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in a corridor is more than 100 feet or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Action required - Provide exit signage in corridors 112 and 123 towards the rear of the space providing direction to door 110. Mike Weisenborn 09/18/2013 2:55 PM - Corrections have been made.
Fire Plan Review Approved with Conditions 09/23/2013 09/18/2013
Mike Weisenborn
Address numbers required
Corrective Action Required
09/18/2013

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Provide addressing, verified at inspection
Portable fire extinguishers - general
Corrective Action Required
09/18/2013

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of a 2A10B:C extinguisher for every 3,000 sq/ft or for every 75' of travel distance. Verified at inspection
Fire Plan Review Approved with Conditions 09/16/2013 09/18/2013
Mike Weisenborn
Address numbers required
Corrective Action Required
09/10/2013

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Provide addressing, verified at inspection
Portable fire extinguishers - general
Corrective Action Required
09/10/2013

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of a 2A10B:C extinguisher for every 3,000 sq/ft or for every 75' of travel distance. Verified at inspection
Building Plan Review Rejected 09/16/2013 09/10/2013
Mike Weisenborn
Plumb - Separate facilities
Corrective Action Required
09/10/2013

2006 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (See code for possible exceptions.) Action required - Please label one of the restrooms as men's and one as women's.
Bldg - Exit signage - Where required
Corrective Action Required
09/10/2013

2006 IBC 1011.1 - Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in a corridor is more than 100 feet or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Action required - Provide exit signage in corridors 112 and 123 towards the rear of the space providing direction to door 110.
Bldg - Corridors - Construction
Resolved
09/10/2013

2006 IBC 1017.1 - Construction. Corridors shall be fire-resistance rated in accordance with Table 1017.1. The corridor walls required to be fire-resistance rated shall comply with Section 708 for fire partitions. Action required - Evan though the occupant load of the space is greater than 50 if all spaces are fully occupied at the same time, the occupant load on any corridor does not exceed 50 based on the configuration of the space. Therefore the corridors are not required to be rated.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $1,538.60 $1,538.60 Paid 12/03/2013
$1,538.60
8331507-Sewer Connection Fee $510.00 $510.00 Paid 12/03/2013
$510.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 12/9/2013 12/10/2013 at 12:00 AM 12/10/2013
Misc
Partial Correction
12/10/2013
OK TO COVER WHEN READY UNDER-SLAB PVC SANITARY DRAIN, WASTE, & VENT PIPING LOWER LIFT ONLY WHERE TWO LIFTS OCCUR -- UPPER LIFT YET TO BE BEDDED AND APPROVED; NOTE IPC 312 / IRC P2503.5.1 REQUIREMENT FOR PRESSURE-TESTING PIPING SYSTEM.
Underslab Plumbing Inspection - Commercial Passed 12/10/2013 at 12:00 AM 12/10/2013
Misc
Resolved
12/10/2013
OK TO COVER WHEN READY UNDER-SLAB PVC SANITARY DRAIN, WASTE, & VENT PIPING LOWER LIFT ONLY WHERE TWO LIFTS OCCUR -- UPPER LIFT YET TO BE BEDDED AND APPROVED; UPPER LIFT BEDDED AND APPROVED NOTE IPC 312 / IRC P2503.5.1 REQUIREMENT FOR PRESSURE-TESTING PIPING SYSTEM.
Underslab Electrical Inspection - Commercial Passed 12/12/2013 12/12/2013 at 12:00 AM 12/12/2013
Electrical Service Inspection Not Ready 12/30/2013 at 12:00 AM 12/30/2013
Misc
Corrective Action Required
12/30/2013
INSTALLATION, INSIDE AND OUTSIDE, DOES NOT REFLECT APPROVED DRAWINGS. UFER GROUND NOT FOUND INSTALLED.
In-wall Inspection Failed 1/9/2014 1/9/2014 at 12:00 AM 01/09/2014
Misc
Corrective Action Required
01/09/2014
IPC - PROTECTION OF COPPER PIPING AT PENETRATION OF STEEL FRAMING MEMBERS: INSTALL GROMMETS OR OTHER APPROVED PROTECTION FROM SHARP EDGES & DISSIMILAR METAL.
Misc
Corrective Action Required
01/09/2014
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
01/09/2014
MOUNTING OF IN-WALL ELECTRICAL BOXES: SECURE AGAINST DEFLECTION. USE STAND-OFFS OR EQUAL TO PREVENT MOVEMENT OF BOX.
Above Ceiling Inspection Partial 01/09/2014
Misc
Partial Correction
01/09/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115 VERTICAL FACES ONLY;
Electrical Service Inspection Passed 1/10/2014 1/10/2014 at 12:00 AM 01/10/2014
Misc
Resolved
01/10/2014
INSTALLATION, INSIDE AND OUTSIDE, DOES NOT REFLECT APPROVED DRAWINGS. UFER GROUND NOT FOUND INSTALLED.
In-wall Inspection Passed 1/10/2014 1/10/2014 at 12:00 AM 01/10/2014
Misc
Resolved
01/10/2014
IPC - PROTECTION OF COPPER PIPING AT PENETRATION OF STEEL FRAMING MEMBERS: INSTALL GROMMETS OR OTHER APPROVED PROTECTION FROM SHARP EDGES & DISSIMILAR METAL.
Misc
Resolved
01/10/2014
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Resolved
01/10/2014
MOUNTING OF IN-WALL ELECTRICAL BOXES: SECURE AGAINST DEFLECTION. USE STAND-OFFS OR EQUAL TO PREVENT MOVEMENT OF BOX.
Above Ceiling Inspection Partial 1/10/2014 at 12:00 AM 01/10/2014
Misc
Partial Correction
01/09/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115 VERTICAL FACES ONLY;
Misc
Partial Correction
01/10/2014
AT SPACE 103 OK TO HANG GWB AT VERTICAL SURFACES AND TO APPLY PLYWOOD BACKING TO HORIZONTAL PLANE. ABOVE-CEILING INSPECTION TO BE DONE FROM LADDER AFTER ABOVE-CEILING SYSTEMS ARE COMPLETED.
Above Ceiling Inspection Partial 1/17/2014 1/17/2014 at 12:00 AM 01/17/2014
Misc
Partial Correction
01/10/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115 COMPLETE; 105; 107; 124;
Misc
Partial Correction
01/10/2014
AT SPACE 103 OK TO HANG GWB AT VERTICAL SURFACES AND TO APPLY PLYWOOD BACKING TO HORIZONTAL PLANE. ABOVE-CEILING INSPECTION TO BE DONE FROM LADDER AFTER ABOVE-CEILING SYSTEMS ARE COMPLETED.
Above Ceiling Inspection Partial 1/21/2014 1/21/2014 at 12:00 AM 01/21/2014
Misc
Partial Correction
01/17/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115; 105; 107; 124; GWB CLOUD @ 103;
Misc
Resolved
01/21/2014
AT SPACE 103 OK TO HANG GWB AT VERTICAL SURFACES AND TO APPLY PLYWOOD BACKING TO HORIZONTAL PLANE. ABOVE-CEILING INSPECTION TO BE DONE FROM LADDER AFTER ABOVE-CEILING SYSTEMS ARE COMPLETED.
Rough Electrical Inspection - Commercial Passed 2/13/2014 2/13/2014 at 12:00 AM 02/13/2014
Above Ceiling Inspection Partial 2/14/2014 at 12:00 AM 02/14/2014
Misc
Partial Correction
01/21/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115; 105; 107; 124; GWB CLOUD @ 103;
Misc
Partial Correction
02/14/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES AFTER TEMPORARY WIRING IS REMOVED: 102-103; 106; 108; 110-111; 113-114; 116-119; 121-122; 127;
Miscellaneous Inspection Partial 2/18/2014 at 12:00 AM 02/18/2014
Above Ceiling Inspection Passed 3/10/2014 3/10/2014 at 12:00 AM 03/10/2014
Misc
Resolved
03/10/2014
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING LOCATIONS: SOFFIT AT 116 W WALL; SOFFIT AT 115; 105; 107; 124; GWB CLOUD @ 103;
Misc
Resolved
03/10/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES AFTER TEMPORARY WIRING IS REMOVED: 102-103; 106; 108; 110-111; 113-114; 116-119; 121-122; 127;
Miscellaneous Inspection Passed 3/11/2014 at 12:00 AM 03/11/2014
Occupancy Inspection - Fire Passed 3/17/2014 at 12:00 AM 03/12/2014
Occupancy Inspection - Codes Commercial Not Ready 3/12/2014 3/12/2014 at 12:00 AM 03/12/2014
Misc
Partial Correction
03/12/2014
FIRE DEPARTMENT ISSUES: NONE REMAINING
Misc
Corrective Action Required
03/12/2014
WATER DEPARTMENT ISSUES: TO BE RESOLVED
Misc
Corrective Action Required
03/12/2014
PUBLIC WORKS ISSUES: REMAINING SITEWORK SUBJECT TO APPROVAL
Misc
Corrective Action Required
03/12/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Corrective Action Required
03/12/2014
ROOFTOP INSPECTION: - NUMBER OR LETTER RTU'S; REFLECT AT E-PANEL - PROTECT LOW VOLTAGE WIRING @ EAST WALL - COMPLETE PAINTING GAS PIPING - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Misc
Corrective Action Required
03/12/2014
DESIGNATE TWO ELECT SERVICE DISCONNECTS OUTSIDE BUILDING; DESIGNATE TWO E-PANELS INSIDE.
Misc
Corrective Action Required
03/12/2014
ALL EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/12/2014
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. NO PATIENTS NOR PUBLIC PRIOR TO APPROVAL.
Occupancy Inspection - Codes Commercial Partial 3/17/2014 at 12:00 AM 03/17/2014
Misc
Resolved
03/17/2014
FIRE DEPARTMENT ISSUES: NONE REMAINING
Misc
Corrective Action Required
03/12/2014
WATER DEPARTMENT ISSUES: TO BE RESOLVED
Misc
Corrective Action Required
03/12/2014
PUBLIC WORKS ISSUES: REMAINING SITEWORK SUBJECT TO APPROVAL
Misc
Corrective Action Required
03/12/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Corrective Action Required
03/12/2014
ROOFTOP INSPECTION: - PROTECT LOW VOLTAGE WIRING @ EAST WALL - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Misc
Resolved
03/17/2014
DESIGNATE TWO ELECT SERVICE DISCONNECTS OUTSIDE BUILDING; DESIGNATE TWO E-PANELS INSIDE.
Misc
Corrective Action Required
03/12/2014
ALL EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/12/2014
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. NO PATIENTS NOR PUBLIC PRIOR TO APPROVAL.
Occupancy Inspection - Codes Commercial Partial 3/18/2014 at 12:00 AM 03/18/2014
Misc
Resolved
03/18/2014
WATER DEPARTMENT ISSUES: TO BE RESOLVED
Misc
Corrective Action Required
03/17/2014
PUBLIC WORKS ISSUES: REMAINING SITEWORK SUBJECT TO APPROVAL
Misc
Corrective Action Required
03/17/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Corrective Action Required
03/17/2014
ROOFTOP INSPECTION: - PROTECT LOW VOLTAGE WIRING @ EAST WALL - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Misc
Corrective Action Required
03/17/2014
ALL EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/17/2014
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. NO PATIENTS NOR PUBLIC PRIOR TO APPROVAL.
Occupancy Inspection - Codes Commercial Temporary C of O 4/10/2014 4/10/2014 at 12:00 AM 04/10/2014
Misc
Resolved
04/10/2014
PUBLIC WORKS ISSUES: REMAINING SITEWORK SUBJECT TO APPROVAL
Misc
Corrective Action Required
03/18/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Corrective Action Required
03/18/2014
ROOFTOP INSPECTION: - PROTECT LOW VOLTAGE WIRING @ EAST WALL - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Misc
Resolved
04/10/2014
ALL EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Resolved
04/10/2014
OCCUPANCY STATUS: OK TO SET UP FOR BUSINESS. NO PATIENTS NOR PUBLIC PRIOR TO APPROVAL.
Occupancy Inspection - Codes Commercial Temporary C of O 4/29/2014 at 12:00 AM 04/29/2014
Misc
Corrective Action Required
04/10/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Corrective Action Required
04/10/2014
ROOFTOP INSPECTION: - PROTECT LOW VOLTAGE WIRING @ EAST WALL - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Occupancy Inspection - Codes Commercial Full C of O 5/7/2014 5/9/2014 at 12:00 AM 05/09/2014
Misc
Resolved
05/09/2014
PLANNING DEPARTMENT INSPECTION PENDING COMPLETION OF SITEWORK
Misc
Resolved
05/07/2014
ROOFTOP INSPECTION: - PROTECT LOW VOLTAGE WIRING @ EAST WALL - CLEAR/CLEAN ROOF SURFACE -- ALL MATERIAL
Documents & Images
Date Uploaded File Type Document Name
09/10/2013 Letter Fire Building Plan Review
09/10/2013 Letter Codes Plan Review Conditions
09/17/2013 Letter Fire Building Plan Review
12/02/2013 Letter Codes Plan Review Conditions
12/03/2013 Letter Codes Building Permit
12/10/2013 Letter Inspection Summary
12/10/2013 Letter Inspection Summary
12/12/2013 Letter Inspection Summary
12/30/2013 Letter Inspection Summary
01/09/2014 Letter Inspection Summary
01/10/2014 Letter Inspection Summary
01/17/2014 Letter Inspection Summary
01/21/2014 Letter Inspection Summary
02/13/2014 Letter Inspection Summary
02/14/2014 Letter Inspection Summary
03/10/2014 Letter Inspection Summary
03/12/2014 Letter Inspection Summary
04/10/2014 Letter Codes Temporary Certificate of Occupancy
04/25/2014 Letter Codes 10 Day Letter
04/29/2014 Letter Codes Temporary Certificate of Occupancy
05/09/2014 Letter Field Certificate of Occupancy
05/12/2014 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home