Permit Application Status

PRCOM20130254


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20130254
Building Permit - Commercial
Final Completion
DACUR INVESTMENT COMPANY INC
ALTERATION COMMERCIAL
FACADE RENOVATION FOR SHELL BUILDING IN FRONT OF SPACES 224 AND 232.
02/22/2013
04/26/2013
09/02/2013
07/12/2013
Locations
Contacts
ALLIED RETAIL CONCEPTS LLC, Address:6205 GODDARD ST, Phone:(913) 492-8008  
AMAI ARCHITECTURE, Address:1510 WALNUT STE 200, Phone:(816) 994-5900  
CURRY REAL ESTATE, Address:2700 Kendallwood Pkwy, Suite 208, Phone:(816) 414-5234  
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 09/02/2013 04/19/2013
Codes Admin
Business License
Corrective Action Required
03/06/2013

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Provide the name of the licensed general contractor for the project. This information is required for permit approval.
Building Plan Review Approved 03/14/2013 03/12/2013
Mike Weisenborn
Bldg - Attic spaces - Access
Resolved
03/12/2013

2006 IBC 1209.2 - Attic spaces. An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches. A 30-inch minimum clear headroom in the attic space shall be provided at or above the access opening. Action required - Provide access into the enclosed space. Mike Weisenborn 03/12/2013 9:31 AM - Corrections have been made.
Building Plan Review Rejected 03/06/2013 03/06/2013
Mike Weisenborn
Bldg - Attic spaces - Access
Corrective Action Required
03/06/2013

2006 IBC 1209.2 - Attic spaces. An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches. A 30-inch minimum clear headroom in the attic space shall be provided at or above the access opening. Action required - Provide access into the enclosed space.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $379.39 $379.39 Paid 04/26/2013
$379.39
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Partial 6/4/2013 6/4/2013 at 12:00 AM 06/04/2013
Misc
Partial Correction
06/04/2013
OK TO COVER WHEN READY FRAMING & ELECT AT FACADE ABOVE SOFFIT ELEVATION. BELOW SOFFIT ELEVATION: 1) DRAWING CALLS FOR PREP & PAINTING OF EXSTG COLUMNS 2) SCREW ALL FLANGE CONNECTIONS ON LIGHT-GAUGE STEEL FRAMING.
All Rough Inspection - Commercial Partial 6/6/2013 6/6/2013 at 12:00 AM 06/06/2013
Misc
Partial Correction
06/04/2013
OK TO COVER WHEN READY FRAMING & ELECT AT FACADE ABOVE & BELOW SOFFIT ELEVATION. NOTED: BOTTOMS OF ALL STEEL COLUMNS HAVE BEEN SPRAYED WITH RUSTOLEUM PRIMER WHERE RUSTED OR BARE METAL. ABOVE-CEILING SYSTEMS AT SOFFIT SUBJECT TO APPROVAL WHEN READY
All Rough Inspection - Commercial Partial 6/13/2013 6/13/2013 at 12:00 AM 06/13/2013
Misc
Partial Correction
06/06/2013
OK TO COVER WHEN READY FRAMING & ELECT AT FACADE ABOVE & BELOW SOFFIT ELEVATION. ABOVE-CEILING SYSTEMS AT SOFFIT SUBJECT TO APPROVAL WHEN READY
Misc
Partial Correction
06/13/2013
NO ISSUES FOUND ON INSTALLATION OF 45-DEGREE BRACES ON BACK-SIDE OF FACADE
Above Ceiling Inspection Passed 6/24/2013 at 12:00 AM 06/24/2013
All Rough Inspection - Commercial Passed 6/24/2013 6/24/2013 at 12:00 AM 06/24/2013
Misc
Resolved
06/24/2013
OK TO COVER WHEN READY FRAMING & ELECT AT FACADE ABOVE & BELOW SOFFIT ELEVATION. ABOVE-CEILING SYSTEMS AT SOFFIT SUBJECT TO APPROVAL WHEN READY
Misc
Resolved
06/24/2013
NO ISSUES FOUND ON INSTALLATION OF 45-DEGREE BRACES ON BACK-SIDE OF FACADE
Final Inspection - Commercial Passed 7/12/2013 at 12:00 AM 07/12/2013
Documents & Images
Date Uploaded File Type Document Name
03/06/2013 Letter Plan Review Conditions
04/26/2013 Letter Building Permit
06/13/2013 Letter Inspection Summary
06/24/2013 Letter Inspection Summary
06/27/2013 Letter Plan Review Conditions
07/12/2013 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home