Summary
PRCOM20122215
Building Permit - Commercial
Certificate of Occupancy
EVANS JOHN S &
CHANGE OF TENANT
TEMPORARY HOLIDAY STORE
10/05/2012
10/29/2012
11/07/2012
Locations
Contacts
GRAYLING INC, Address:10258 W 87TH ST, Phone:(913) 341-5444  
EVANS JOHN S &, Address:208 SW ASPEN  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/17/2012 10/19/2012
Mike Weisenborn
True
Zoning Review Approved 10/17/2012 10/12/2012
Mike Weisenborn
License Tax Codes Approved 10/17/2012 10/12/2012
Mike Weisenborn
Building Plan Review Approved 10/17/2012 10/12/2012
Mike Weisenborn
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
10/12/2012

2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - Compliance will be verified on inspection.
Plumb - Required public toilet facilities
Corrective Action Required
10/12/2012

2006 IPC 403.4 - Required public toilet facilities. Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The accessible route to public facilities shall not pass through kitchens, storage rooms, closets or similar spaces. Employees shall be provided with toilet facilities in all occupancies. Employee toilet facilities shall be either separate or combined employee and public toilet facilities. Action required - This comment is for information purposes.
Fire Plan Review Approved with Conditions 10/17/2012 10/12/2012
Jim Eden
Misc
Corrective Action Required
10/12/2012

Exit and emergency lighting shall be provided or maintained from the front and back of the building. Verified at inspection.
Misc
Corrective Action Required
10/12/2012

1014.2 Egress through intervening spaces. Egress through intervening spaces shall comply with this section. 1.Egress from a room or space shall not pass through adjoining or intervening rooms or areas, except where such adjoining rooms or areas are accessory to the area served, are not a high-hazard occupancy and provide a discernible path of egress travel to an exit. Exception: Means of egress are not prohibited through adjoining or intervening rooms or spaces in a Group H, S or F occupancy when the adjoining or intervening rooms or spaces are the same or a lesser hazard occupancy group. 2.Egress shall not pass through kitchens, storage rooms, closets or spaces used for similar purposes. Exceptions: 1.Means of egress are not prohibited through a kitchen area serving adjoining rooms constituting part of the same dwelling unit or sleeping unit. 2.Means of egress are not prohibited through stockrooms in Group M occupancies when all of the following are met: 2.1. The stock is of the same hazard classification as that found in the main retail area; 2.2. Not more than 50 percent of the exit access is through the stockroom; 2.3. The stockroom is not subject to locking from the egress side; and 2.4. There is a demarcated, minimum 44-inch-wide (1118 mm) aisle defined by full or partial height fixed walls or similar construction that will maintain the required width and lead directly from the retail area to the exit without obstructions. 3. An exit access shall not pass through a room that can be locked to prevent egress. 4. Means of egress from dwelling units or sleeping areas shall not lead through other sleeping areas, toilet rooms or bathrooms Action required: Maintain a marked path through the storage room. Verified at inspection.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $30.00 $30.00 Paid 10/29/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Commercial Full C of O 11/7/2012 11/7/2012 at 12:00 AM 11/07/2012
Documents & Images
Date Uploaded File Type Document Name
10/29/2012 Letter Plan Review Conditions
10/29/2012 Letter Building Permit
11/07/2012 Letter Field Certificate of Occupancy
11/08/2012 Letter Final Certificate of Occupancy
06/21/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home