Summary
PRCOM20121671
Building Permit - Commercial
Final Completion
ASSOCIATED PEDIATRIC INVESTORS LLC
PARTIAL COMMERCIAL
FOUNDATION AND UNDERSLAB ONLY
07/24/2012
07/25/2012
03/26/2013
Locations
Contacts
ASSOCIATED PEDIATRIC INVESTORS LLC, Address:1425 NW BLUE PKWY  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
CENTRAL PLUMBING HTG & A/C INC, Address:P O BOX 218, Phone:(816) 942-6355  
A L HUBER INC, Address:10770 EL MONTE, Phone:(913) 341-4880  
Reviews
Review Type Outcome Est. Completion Date Completed
Alarm Plan Review Released for Construction 08/07/2012 10/25/2012
Jim Eden
Construction documents for fire alarm systems
Corrective Action Required
10/25/2012

2006 IFC 907.1.1- Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: 1. .A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions. Plans received October 18, 2012.
Misc
Corrective Action Required
10/25/2012

Duct detection activation shall be supervisory only at the panel and Central Station and shall NOT activate interior horn/strobe notification appliances. Verified at inspection.
Installation acceptance testing
Corrective Action Required
10/25/2012

2006 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Tested at occupancy inspection.
Internal Plan Review (Res) Approved 07/24/2012
Mike Weisenborn
True
Fire Plan Review Approved 07/24/2012
Mike Weisenborn
Building Plan Review Approved 07/24/2012
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Partial Commercial $159.80 $159.80 Paid 07/25/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
07/25/2012 Letter Building Permit
06/27/2013 Letter Fire (Alarm) Plan Review Notice
06/27/2013 Letter Plan Review Conditions
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home