Permit Application Status

PRCOM20100149


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20100149
Building Permit - Commercial
Final Completion
SUMMIT WOODS SPE LLC
REPAIR REPLACE UPGRADE
Modify NG, plumbing and electrical for replacement of cooking equipment
11/23/2010
11/23/2010
12/23/2010
Locations
Contacts
CARLSON CONSTRUCTION MANAGEMENT, Address:P O BOX 3098, Phone:(816) 795-1660  
HERMAN ELECTRIC INC, Address:5450 W 295TH ST, Phone:(816) 524-6105  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
SUMMIT WOODS SPE LLC, Address:1 E WASHINGTON ST STE 300  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved 12/07/2010 11/24/2010
Jim Eden
Misc
Corrective Action Required
11/24/2010

Fire Department- IFC 4.11.6.1 Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and classified grease filters shall be in place when equipment under a kitchen grease hood is used. 904.11.6.2 Grease extractors. Where grease extractors are installed, they shall be operated when the commercial-type cooking equipment is used. 904.11.6.3 Cleaning. Hoods, grease-removal devices, fans, ducts and other appurtenances shall be cleaned at intervals necessary to prevent the accumulation of grease. Cleanings shall be recorded, and records shall state the extent, time and date of cleaning. Such records shall be maintained on the premises. 904.11.6.4 Extinguishing system service. Automatic fire-extinguishing systems shall be serviced at least every 6 months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Action required: The hood suppression system shall be altered or maintained to provide required coverage of appliances under the hood. Verified at inspection.
Internal Plan Review (Res) Approved 11/23/2010
Codes Admin
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Repair/Replace/Upgrade $102.62 $102.62 Paid 11/23/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Above Ceiling Inspection Passed 12/22/2010 at 12:00 AM 12/22/2010
Gas Piping Inspection - Commercial Failed 12/22/2010 at 12:00 AM 12/22/2010
Misc
Corrective Action Required
12/22/2010
GAS PIPING PRESSURE TEST LOST 1/2 PSI IN 15 MINUTES. IDENTIFY AND ELIMINATE LEAK.
Underslab Plumbing Inspection - Commercial Passed 12/23/2010
Gas Piping Inspection - Commercial Passed 12/23/2010 at 12:00 AM 12/23/2010
Misc
Resolved
12/23/2010
GAS PIPING PRESSURE TEST LOST 1/2 PSI IN 15 MINUTES. IDENTIFY AND ELIMINATE LEAK.
In-wall Inspection Passed 12/23/2010 at 12:00 AM 12/23/2010
Misc
Partial Correction
12/21/2010
NO ISSUES FOUND @ LOWER 2' OF IN-WALL SYSTEMS @ COOKLINE EXCEPT GAS PIPING PRESSURE TEST NOT APPROVED -- NOT PRESSURED UP TO 10+ PSI
In-wall Inspection Passed 12/23/2010 at 12:00 AM 12/23/2010
Misc
Partial Correction
12/21/2010
NO ISSUES FOUND @ LOWER 2' OF IN-WALL SYSTEMS @ COOKLINE EXCEPT GAS PIPING PRESSURE TEST NOT APPROVED -- NOT PRESSURED UP TO 10+ PSI
Occupancy Inspection - Fire Passed 12/29/2010
Final Inspection - Commercial Passed 12/23/2010 at 12:00 AM 03/11/2011
Misc
Resolved
03/11/2011
CONTACT FIRE DEPARTMENT REGARDING FINAL INSPECTION -- OBTAIN APPROVAL OR DETRMINATION THAT FD FINAL INSPECTION NOT REQUIRED.
Misc
Resolved
03/11/2011
NON-ABSORBENT FLOOR FINISH IN KITCHEN YET TO BE INSTALLED.
Misc
Resolved
03/11/2011
INSTALL ESCUTCHEONS ON SPRINKLER F.P. HEADS
Misc
Resolved
03/11/2011
REPLACE MISSING DIGITS ON ADDRESS LABEL AT REAR DOOR.
Documents & Images
Date Uploaded File Type Document Name
11/23/2010 Letter Building Permit
12/21/2010 Letter Inspection Summary
12/22/2010 Letter Inspection Summary
12/23/2010 Letter Inspection Summary
12/29/2010 Letter Fire Loss Reduction Form
03/11/2011 Letter Inspection Summary
06/28/2013 Letter Plan Review Conditions
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home