THE VILLAS OF CHAPEL RIDGE 2ND PLAT, LOTS 43-74 AND TRACTS C-1 AND D-1 - PUBLIC SANITARY SEWER
Engineering Plan Review
Engineering Plan Review
Approved
06/27/2022
CHOYCE LLC
PUBLIC SANITARY FOR SINGLE FAMILY DEVELOPMENT
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
ENGINEERING SOLUTIONS, Address:50 SE 30TH ST, Phone:(816) 623-9888  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Approved with Conditions 06/20/2023 06/20/2023
Gene Williams, P.E.
Engineering Review Approved with Conditions 05/17/2023 05/17/2023
Gene Williams, P.E.
Engineering Review Corrections 03/27/2023 03/31/2023
Gene Williams, P.E.
Corrective Action Required
03/31/2023

Please refer to comment #1 in the previous applicant letter. The response to comments states that notes were provided for constructability. However, this will not work as shown or noted. The detail you have provided is for a manhole frame and lid that is positioned within the geometric center of a driving lane, not the crown of a street. Please provide a re-design with the manhole frame and lids at the geometric center of a driving lane, not the crown of a street. (Informational Note: The manhole frame and lids installed in Napa Valley's latest phase were installed at the crown of the street, and exhibit a severe bump at each manhole).
Engineering Review Corrections 08/31/2022 08/31/2022
Gene Williams, P.E.
Corrective Action Required
08/31/2022

Please refer to previous applicant letter. We requested a detail for a concrete collar placed around the manhole frame and lid. You provided the detail, but it will not function as you have designed the system. You have placed the manhole frame and lids in the geometric center of the road, and the detail provided is for manhole frame and lids centered within the driving lane. If you desire to place the manholes in the geometric center of the pavement, a different detail is needed. We would suggest, however, you place the sanitary sewer manhole frame and lids in the center of either driving lane. Otherwise, it will be difficult to construct anything resembling what you are showing. Please evaluate, review, and revise as appropriate.
Corrective Action Required
08/31/2022

Please show in graphic format what is stated in Note 6 on the cover sheet. This can be in the form of cross-hatching on the profile view for fill areas, and notation. Please revise.
Corrective Action Required
08/31/2022

Please be aware an MDNR permit shall not be required since this project is less than 1000 feet of public sanitary sewer main.
Engineering Review Corrections 07/15/2022 07/15/2022
Gene Williams, P.E.
Corrective Action Required
07/15/2022

Existing manhole numbers were missing. Please provide existing manhole numbers.
Corrective Action Required
07/15/2022

Street patch in the form of concrete "collar" around each manhole installed within the streets are required. Please contact me if you need to see a detail used on previous projects. In general, a square around the manhole is required with KCMMB concrete eight (8) inches thick, with the square lined-up to reveal a diamond-shape as viewed driving down the lane. It may be beneficial to center the manholes in the driving lane rather than the center of the road to avoid crown issues. Please contact me to discuss.
Corrective Action Required
07/15/2022

C.402: Sanitary Manhole A-3 has a FL In (S) of 922.00 in the Profile for Sanitary Line A and a FL In (S) of 922.50 in the Profile for Sanitary Line B. Please correct and reconcile.
Corrective Action Required
07/15/2022

C.402: Verify the slope between Sanitary Manhole A-1 and Ex. Sanitary Manhole on Sanitary Line A. Please correct if necessary.
Corrective Action Required
07/15/2022

C.403: The information contained in the “Sewer Stub Table – Existing Line” for the existing sewer stubs differs from the information provided in the Chapel Ridge Phase I As-builts. Please confirm the information populated in the table on the existing sewer stubs is reliable.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
06/27/2022 Plans VILLAS SANITARY
07/15/2022 Letter DE-Comment Letter (Engineering Plans)
08/17/2022 Plans SANITARY 8-17-2022
08/17/2022 Engineers Estimate COST ESTIMATE SANITARY 8-12-2022
08/17/2022 Letter Comment Letter SANITARY 8-12-2022
08/31/2022 Letter DE-Comment Letter (Engineering Plans)
03/13/2023 Plans SANITARY 20230303
03/13/2023 Letter Comment Letter SANITARY 3-7-23
03/31/2023 Letter DE-Comment Letter (Engineering Plans)
05/02/2023 Plans Sanitary Plans
05/02/2023 Engineers Estimate Sealed Cost Estimate Sanitary 230418
05/02/2023 Letter Comment Letter SANITARY 230418
05/17/2023 Email STKY APPROVAL
06/13/2023 Engineers Estimate Sealed Cost Estimate Sanitary 230613
06/20/2023 Activity Document FeeWorksheetVillasChapelRidge2ndSanitary
10/30/2024 Plans Stamped Approved Plans FDP Sanitary_PL2022247
10/31/2024 Email Approval Email_PL2022247
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home