Planning Application Status

PL2021441




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2021441
Summit Creek 1st Plat - Public Sanitary
Engineering Plan Review
Engineering Plan Review
Void
11/10/2021
291 INVESTORS LLC
APPLICATION EXPIRED - Mike Weisenborn 01/10/2024 9:21 AM
Locations
Contacts
291 INVESTORS LLC, Address:900 W 48TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
ENGINEERING SOLUTIONS, Address:50 SE 30TH ST, Phone:(816) 623-9888  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Approved with Conditions 02/10/2022 01/28/2022
Sue Pyles, P.E.
Engineering Review Approved with Conditions 01/14/2022 01/14/2022
Sue Pyles, P.E.
Engineering Review Corrections 01/07/2022 01/07/2022
Sue Pyles, P.E.
Corrective Action Required
01/07/2022

Sheet C.401: Please provide a legend to clarify the dashed lines and hatched area. Please make this revision to all of the plan sets on this project.
Corrective Action Required
01/07/2022

Sheets C.402 & C.405: Include the following note: “Compacted Fill shall be placed to a minimum 18” above the top of the pipe prior to installation.” Show and label the limits of the compacted fill placement in the Profile view. Use hatching for clarity.
Corrective Action Required
01/07/2022

Please review the Line B stationing in Profile view and revise as needed. Revise the Summary of Quantities table and the Engineer's Estimate if needed.
Engineering Review Corrections 12/10/2021 12/10/2021
Sue Pyles, P.E.
Corrective Action Required
12/10/2021

Please submit an Engineer’s Estimate of Probable Construction Costs and a copy of the MDNR permit.
Corrective Action Required
12/10/2021

SHEET C.400 – Construction and design note 2 indicates that the sewer laterals shall be shown on the plans; however, there are no lateral shown in the plan set. Please add the lateral to either sheet C.401 or on the profile sheets.
Corrective Action Required
12/10/2021

SHEET C.404 – Please show the proposed storm line that runs between manholes A-2 and B-1.
Corrective Action Required
12/10/2021

SHEET C.404 – The sanitary main at approximately sta 1+00 does not meet minimum horizontal separation from the proposed water main.
Hearings

There are no hearings for this planning application.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your Planning Application