Summary
PL2020030
CHAPEL RIDGE BUSINESS PARK - LOTS 9BB, 9C, 9D - WATERLINE PLANS
Engineering Plan Review
Engineering Plan Review
Approved
02/12/2020
CRCP INVESTMENTS LLC
Locations
Contacts
CRCP INVESTMENTS LLC, Address:3170 NE CARNEGIE DR STE 400  
ENGINEERING SOLUTIONS, Address:50 SE 30TH ST, Phone:(816) 623-9888  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Corrections 02/21/2020 02/21/2020
Joshua Johnson
Engineering Review Corrections 02/27/2020 02/14/2020
Gene Williams, P.E.
Corrective Action Required
02/14/2020

Ductile iron pipe is called-out. The City requires C900 pipe, unless the applicant is willing to install zinc-coated ductile iron pipe. Any ductile iron pipe installed within the City from this point forward is required to be zinc-coated.
Corrective Action Required
02/14/2020

All Sheets: There is reference showing existing water main in areas where water main does not exist. Please remove these references where existing water mains do not exist.
Corrective Action Required
02/14/2020

The water main should be extended a sufficient length to install a fire hydrant in an offset fashion. The length should also be sufficient to connect a future water meter immediately adjacent to Lot 9-C.
Corrective Action Required
02/14/2020

A fire hydrant was missing at the termination of the line. Please see above comment concerning the geometry of this new fire hydrant.
Corrective Action Required
02/14/2020

A trenching and backfill detail was missing.
Corrective Action Required
02/14/2020

The estimate was missing a fire hydrant. In addition, quantities and material type will likely change based on the comments presented in this letter.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
02/12/2020 Plans Binder1
02/12/2020 Letter Routing Sheet
02/14/2020 Letter DE-Comment Letter (Engineering Plans)
02/14/2020 Letter Resubmittal Routing Sheet
03/31/2020 Approved Plans Approved Water Chapel Ridge 9
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home