Review Type |
Outcome |
Est. Completion Date |
Completed |
GIS Review
|
Approved with Conditions
|
12/20/2018
|
12/20/2018
|
|
Mike Weisenborn
|
|
Corrective Action Required
Owners name should be underneath the signature line.
|
|
|
Engineering Review
|
Approved with Conditions
|
12/20/2018
|
12/20/2018
|
|
Gene Williams, P.E.
|
|
Corrective Action Required
New easement dedications look acceptable for the existing sanitary sewer. Please remove the sanitary sewer layer from the final mylars.
|
|
|
Planning Review
|
Approved with Conditions
|
12/20/2018
|
12/14/2018
|
|
Hector Soto Jr.
|
|
Corrective Action Required
CITY SIGNATURE BLOCK. Per new requirements, please revise the end of the approval paragraph above the City signature block to read, "...pursuant to Chapter 33, the Unified Development Ordinance, of the Lee's Summit Code of Ordinances."
|
|
|
Planning Review
|
Corrections
|
11/07/2018
|
11/05/2018
|
|
Hector Soto Jr.
|
|
Corrective Action Required
LOT BOUNDARIES. Use a heavier line weight to more easily discern the lot boundaries between Lot 1 and Lot 2 and between Lot 2 and Lot 3.
|
|
Corrective Action Required
SIDEWALKS.
- Show and label the existing sidewalks along NW Moore St, NW O'Brien Rd and NW Murray Rd.
- Label the widths of the above referenced sidewalks.
|
|
Corrective Action Required
STREETS/ADDRESSES.
- Add the NW quadrant prefix to each street name.
- Label the following lots with their respective addresses: Lot 1 - 501 NW Moore St; Lot 2 - 400 NW Murray Rd; and Lot 3 - 506 NW Murray Rd.
|
|
Corrective Action Required
PLAT TITLE.
- Add the lot numbers to the plat title. Revise the plat title references throughout the document as needed to match the updated title.
- Correct the plat title reference in the approval paragraph above the City signature block.
|
|
|
Engineering Review
|
Corrections
|
11/07/2018
|
11/01/2018
|
|
Gene Williams, P.E.
|
|
Corrective Action Required
Where a general utility does not exist along street frontage (i.e., Murray Rd., O'Brien Rd., and Moore St.), a ten (10) foot wide general utility easement should be dedicated on the plat.
|
|
Corrective Action Required
In the southeast portion of Lot 2 shown on the proposed plat, there are utility easements shown. Please show the location of the sanitary sewer in relation to these easements. It does not appear there is an adequate easement joining the existing sanitary sewer to O'Brien Rd. This is the sanitary sewer existing within the easement #I-64116. The portion joining the existing sanitary sewer, to O'Brien Rd. appears to be only 5 feet in width, which is not sufficient. The typical width should be specified as twice the depth of the sanitary sewer, assuming the sanitary sewer line is centered within the easement.
|
|
Corrective Action Required
There appear to be several extraneous easements that may need to be vacated by a separate process (i.e., Vacation of Easement process). This may include easements described by the following document numbers: 1) a portion of I-56726, 2) the 5 foot utility easement by plat, document number I-917602, 3) I-113355, 4) the 5 foot utility easement by plat, document number I-154129, 5) I-12534, and 6) the 14 foot wide utlity easement by plat, document number I-154129.
|
|
Corrective Action Required
Sidewalks should be shown along all street frontage.
|
|
|
GIS Review
|
Corrections
|
11/07/2018
|
10/31/2018
|
|
Kathy Kraemer
|
|
Corrective Action Required
Owners name should be underneath the signature line.
|
|
|