Planning Application Status

PL2017212




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2017212
COLEMAN EQUIPMENT WATER LINE PLANS
Engineering Plan Review
Engineering Plan Review
Complete
09/25/2017
TUF FLIGHT INDUSTRIES INC
Locations
Contacts
SCHLAGEL & ASSOCIATES, Address:14920 W 107TH ST, Phone:(913) 492-5158  
TUF FLIGHT INDUSTRIES INC, Address:6330 NW KELLY DR  
B & D BUSINESS HOLDINGS LLC, Address:24000 W 43RD STREET  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 11/28/2017 11/21/2017
Sue Pyles, P.E.
Engineering Review Corrections 11/08/2017 11/07/2017
Sue Pyles, P.E.
Corrective Action Required
11/07/2017

Please remove the casing pipe from the plans and the estimate, and also remove the associated standard detail.
Corrective Action Required
11/07/2017

Per LS Section 6901.E.1.b, 2 valves are required at the proposed connection. Please include a valve on the existing line either east or west of the connection, as well as a valve north of the connection on the new line.
Corrective Action Required
11/07/2017

Revise plans to reflect any revisions to the plat.
Engineering Review Corrections 10/19/2017 10/17/2017
Sue Pyles, P.E.
Corrective Action Required
10/10/2017

Submit an Engineer's Estimate of Probable Construction Costs.
Corrective Action Required
10/10/2017

Screen back the future lot numbers and label as "Future" throughout the plan set.
Corrective Action Required
10/10/2017

Sheets W1.0-2.0: Include the direction of each valve being installed.
Corrective Action Required
10/10/2017

Include Standard Detail WAT-5.
Corrective Action Required
10/17/2017

Revise plans to reflect any revisions to the plat.
Corrective Action Required
10/17/2017

Plans must be signed/sealed by a licensed engineer.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
09/28/2017 Plans 2017.09.26-17-019 WATER REV0
10/17/2017 Letter DE-Comment Letter (Engineering Plans)
11/07/2017 Letter DE-Comment Letter (Engineering Plans)
12/22/2017 Letter DE-Engineering Plans Approval Letter
01/19/2018 Activity Document Fees PL2017212 Coleman Equipment Water
04/06/2018 Engineer Report/Study Coleman Equipment Wate Line - Eng Cost Estimate
03/09/2023 Accepted Record Drawings Coleman Equipment Water AsBuilts Accepted RD
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home