Planning Application Status

PL2013014




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2013014
INSTANT AUTO
Special Use Permit
Special Use Permit
Expired
02/15/2013
BBJV LLC
Locations
Contacts
BBJV LLC, Address:3200 S OUTER RD  
INSTANT AUTO, Address:105 N MAIN STREET, Phone:(816) 847-5111  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:11301 STRANG LINE ROAD  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Condition(s) of Approval 03/01/2013 03/01/2013
Gene Williams, P.E.
Corrective Action Required
03/01/2013

The site is not currently served by a gravity sanitary sewer system. The development to the south (i.e., Subaru) is utilizing a private grinder pump for sanitary sewer service. Arrangements must be made between the applicant and the owners of the Subaru development for adequate sanitary sewer service in the form of a private easement between the two parties, or other suitable alternatives.
Corrective Action Required
03/01/2013

An eight (8) inch public water main extension will be required to complete the loop to the north of the development. Currently, a sixteen (16) inch transmission main is present along this corridor, but is not allowed as a connecting point for domestic or fire line service.
Planning Review Corrections 03/01/2013 02/28/2013
Hector Soto Jr.
Corrective Action Required
02/28/2013

MODIFICATIONS. - Staff will support the requested modification to the 10' display setback requirement from the north and south property lines, to allow 6' setbacks. - Staff will support the requested modification to the requirement that no fence be permitted forward the building, to allow a fenced secured parking area west of the building.
Corrective Action Required
02/28/2013

OPERATIONS. Provide a description of the business in terms of days of operation, hours and number of employees.
Traffic Review No Comments 03/01/2013 02/22/2013
Michael Park
Fire Review Corrections 03/01/2013 02/19/2013
Jim Eden
Code Statement
Corrective Action Required
02/19/2013

Fire Department-All building and life safety issues shall comply with the 2006 International Fire Code and local amendments as adopted by the City of Lee’s Summit.
Hydrants
Corrective Action Required
02/19/2013

"Fire Department- IFC 508.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official." Action Required: Provide a hydrant plan.
Sprinkler System
Corrective Action Required
02/19/2013

Fire Department - An automatic fire sprinkler (suppression) system is required in accordance with the 2006 International Fire Code.
FDC's
Corrective Action Required
02/19/2013

Fire Department-A fire hydrant shall be located within 100 feet of the fire department connection (FDC).
Knox Box
Corrective Action Required
02/19/2013

Fire Department- IFC 506.1 Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type and shall contain keys to gain necessary access as required by the fire code official. An approved lock shall be installed on gates or similar barriers when required by the fire code official.
Imposed Loads
Corrective Action Required
02/19/2013

Fire Department- IFC 503.2.3 Fire apparatus access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be surfaced so as to provide all-weather driving capabilities.
Fees
Paid Fees Amount Paid Owing Date Paid
9110076-Legal Notice Publishing Charge $165.00 $165.00 Paid 02/15/2013
$165.00
9110076-Legal Notice Publishing Charge $165.00 $165.00 Paid 02/15/2013
$165.00
9110077-Special Use Permit fee $900.00 $900.00 Paid 02/15/2013
$900.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Planning Commission Meeting 04/09/2013 05:00 PM Council Chambers 04/09/2013 05:00 PM
Public Hearing Review
Pending
04/09/2013
City Council Public Hearing 05/02/2013 06:15 PM Council Chambers 05/02/2013 06:15 PM
Public Hearing Review
Pending
05/02/2013
City Council Ordinance 05/16/2013 06:15 PM Council Chambers 05/16/2013 06:15 PM
Public Hearing Review
Pending
05/16/2013
Documents & Images
Date Uploaded File Type Document Name
02/15/2013 Letter Routing Sheet
03/01/2013 Letter Applicant Letter - Dev. Apps (DRCP)
05/06/2013 Letter CC PH LTR
05/17/2013 Letter PC LTTR
05/17/2013 Ordinance ordinance
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home