Summary
B0500529
Building Permit - Commercial
Certificate of Occupancy
MILES CATHERINE LAURINE
NEW TENANT FINISH
MARY HASLEY CHIROPRACTOR T/F
04/05/2005
04/20/2005
10/17/2005
12/08/2005
Locations
Contacts
AGMP ARCHITECTS, Address:226 SE DOUGLAS  
D. L. KIRBY PROPERTIES, Address:826 NE SWANN RD  
MILES CATHERINE LAURINE, Address:7728 CONSTANCE  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/02/2005 10/29/2010
Correction

Codes Administration - 2003 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.
Correction

CA - ANSI A117.1-1998 404.2.4.1 - Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.4.1.
Correction

Fire Department-Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type. IFC 1003.3.1.8
Correction

Codes Administration - The floor drains shown in the restrooms where not installed on the ground rough.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex.
Correction

Codes Administration - 2003 IPC 410.1 - Drinking fountains shall conform to ASME A112.19.1M, ASME A112.19.2M or ASME A112.19.9M, and water coolers shall conform to ARI 1010. Drinking fountains and water coolers shall conform to NSF 61, Section 9. Where water is served in restaurants, drinking fountains shall not be required. In other occupancies, where drinking fountains are required, botteled water dispensers or break rooms with a kitchen sink shall be permitted to be substituted for the required drinking fountains. As ammended by the City of Lee's Summit.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $197.00 $197.00 Paid 04/20/2005
24 BLDG Plan Check Fees $16.50 $16.50 Paid 04/20/2005
25 Electrical Permit Fee $80.33 $80.33 Paid 04/20/2005
25 Mechanical Permit Fees $59.50 $59.50 Paid 04/20/2005
25 Plumbing Permit Fees $33.00 $33.00 Paid 04/20/2005
89 Sewer Tap Fees $210.00 $210.00 Paid 04/20/2005
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Passed 04/29/2005
Correction
Resolved
04/29/2005
IN-WALL Identify property. OKAY TO COVER IN WALL WHEN READY.
Electrical Service Inspection Failed 04/29/2005
Correction
Corrective Action Required
04/29/2005
LABEL DISCONNECTS CAN NOT INSPECT SERVICE FOR INDIVIDUAL TENANTS UNTIL DISCONNECTS ARE IDENTIFIED.
Electrical Service Inspection Not Ready 05/31/2005
Correction
Corrective Action Required
05/31/2005
READINESS FOR INSPECTION LSCO SEC 7-142; IBC 106: NO INSPECTIONS WITHOUT PERMIT DRAWINGS PERMIT DRAWINGS NOT FOUND ON SITE
Correction
Resolved
05/31/2005
LABEL DISCONNECTS
Electrical Service Inspection Passed 06/01/2005
Correction
Resolved
06/01/2005
ELECTRICAL SERVICE INSTALLATION RELEASE TWO SERVICES TWO 200 AMP PANELS 2 METERS: A & B
Correction
Resolved
06/01/2005
READINESS FOR INSPECTION
Above Ceiling Inspection Partial 06/03/2005
Correction
Partial Correction
06/03/2005
ABOVE-CEILING SYSTEMS ROUGH OK TO COVER ELSEWHERE DO NOT COVER @ SOUTH WALL NOR AT ATTIC ACCESS HATCH
Correction
Corrective Action Required
06/03/2005
ATTIC ACCESS HATCH NOT CLOSED WITH RATED GWB
Correction
Corrective Action Required
06/03/2005
PENETRATION OF SOUTH DEMISING WALL PERMIT DRAWING SHEET TF-1 STATES "DEMISING WALLS: 1-HR" SHEET TF-2 DETAIL (16) DEPICTS DESIGN UL-305 1-HR WALL BY NON-RATED MATERIALS ROOM 114
Above Ceiling Inspection Passed 06/23/2005
Correction
Resolved
06/23/2005
ABOVE-CEILING SYSTEMS ROUGH OK TO COVER ELSEWHERE DO NOT COVER @ SOUTH WALL NOR AT ATTIC ACCESS HATCH
Correction
Resolved
06/23/2005
ATTIC ACCESS HATCH NOT CLOSED WITH RATED GWB
Correction
Resolved
06/23/2005
PENETRATION OF SOUTH DEMISING WALL PERMIT DRAWING SHEET TF-1 STATES "DEMISING WALLS: 1-HR" SHEET TF-2 DETAIL (16) DEPICTS DESIGN UL-305 1-HR WALL BY NON-RATED MATERIALS ROOM 114
Occupancy Inspection - Codes Commercial Failed 06/23/2005
Correction
Corrective Action Required
06/23/2005
Receive Planning & Development Approval SEE SEPERATE COVER
Correction
Resolved
06/23/2005
Receive Fire Department approval
Correction
Corrective Action Required
06/23/2005
Prevent Physical Damage (IRC) UTILITY ROOM
Correction
Corrective Action Required
06/23/2005
GFCI OUTLETS OUTLETS W/N 6'OF A WATER SOURCE ARE REQUIED TO BE GFCI THROUGHOUT
Occupancy Inspection - Codes Commercial Failed 06/24/2005
Correction
Corrective Action Required
06/24/2005
Grading (IRC) FINAL GRADE AND SOD REQUIRED.
Correction
Corrective Action Required
06/24/2005
Receive Planning & Development Approval SEE SEPERATE COVER
Correction
Resolved
06/24/2005
Prevent Physical Damage (IRC) UTILITY ROOM
Correction
Resolved
06/24/2005
GFCI OUTLETS THROUGHOUT
Occupancy Inspection - Codes Commercial Failed 09/26/2005
Correction
Resolved
09/26/2005
GFCI OUTLETS
Correction
Resolved
09/26/2005
Prevent Physical Damage (IRC)
Correction
Resolved
09/26/2005
Receive Planning & Development Approval
Correction
Resolved
09/26/2005
Grading (IRC)
Correction
Corrective Action Required
09/26/2005
APPROVAL STATUS OF BUILDING SHELL PERMIT AWAITING RESOLUTION OF OUTSTANDING ISSUES
Occupancy Inspection - Codes Commercial Passed 12/07/2005
Correction
Resolved
12/07/2005
GFCI OUTLETS
Correction
Resolved
12/07/2005
Prevent Physical Damage (IRC)
Correction
Resolved
12/07/2005
Receive Fire Department approval
Correction
Resolved
12/07/2005
Receive Planning & Development Approval
Correction
Resolved
12/07/2005
Grading (IRC)
Correction
Resolved
12/07/2005
APPROVAL STATUS OF BUILDING SHELL PERMIT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home