Summary
PRRES20255571
Building Permit - Residential
Final Completion
HUNT MIDWEST RESIDENTIAL LLC
ALTERATION SINGLE FAMILY
ROOF MOUNTED SOLAR - 7.70 KW
12/22/2025
12/29/2025
01/12/2026
Locations
Contacts
Solera Energy LLC, Address:1725 N Packer Rd  
permits@soleraenergyllc.com, Address:permits@soleraenergyllc.com  
HUNT MIDWEST RESIDENTIAL LLC, Address:1881 MAIN ST STE 200  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/24/2025 12/29/2025
Andrea Sessler
Fire Department Solar Review Approved 12/24/2025 12/23/2025
Jim Eden
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Add/Alter Single Family $80.00 $80.00 Paid 12/29/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Passed 1/12/2026 01/12/2026
Electrical Service Inspection Passed 1/12/2026 1/12/2026 01/12/2026
Final Inspection - Residential Passed 1/12/2026 (7:00AM to 4:00PM) 1/12/2026 01/12/2026
Documents & Images
Date Uploaded File Type Document Name
12/22/2025 Application Form APPLICATION
12/22/2025 iRooFAsolar951097DONLENNARDMODataCheck
12/22/2025 CADDonLennardV1DesignPlansets
12/22/2025 iRooFAsolar951097DONLENNARDMOStructuralAnalysiss
12/22/2025 EVERGY - Design has been approved
12/29/2025 Approved Plans APPROVED PLANS
12/29/2025 Permit DS Building Permit
12/29/2025 Receipt Receipt for transaction:2025-009226
01/12/2026 Letter INSPECTION SUMMARY
01/12/2026 Letter INSPECTION SUMMARY
01/12/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home